CoChat

Incidence and Clinical Significance of New-Onset Device-Detected Atrial Tachyarrhythmia: A Meta-Analysis

Open access
Belkin, Mark N., Soria, Cesar E., Waldo, Albert L., Borleffs, C. Jan Willem, Hayes, David L., Tung, Roderick, Singh, Jagmeet P., Upadhyay, Gaurav A. · 2018 · Circulation: Arrhythmia and Electrophysiology
Cited by 23

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

Background: Despite the clear association between atrial fibrillation and risk for thromboembolic events (TEs), the clinical significance of new-onset device-detected atrial tachyarrhythmia (DDAT) and TE remains disputed. We aimed to determine the risk of TE in patients with new-onset DDAT. Methods and Results: The OVID Medline, Cochrane, and Scopus databases (inception to November 2016) were searched. Randomized controlled trials, prospective, or retrospective studies of pacemaker or defibrillator patients reporting incidence of DDAT were selected. Summary statistics were used for analysis. Of 4893 reports identified, 28 studies following 24 984 patients were included: average age 69.9 years, 34.7% women, mean study duration 21.8±18.6 months. New-onset DDAT was observed in 23% of patients. Among 9 studies (n=8181) reporting TE, the absolute incidence was 2.1%. TE risk was significantly greater among patients with new-onset DDAT (relative risk [RR], 2.88; 95% CI, 1.79–4.64; P <0.001). TE risk was correlated with DDAT duration, with an increased risk associated with DDAT ≥5 minutes (RR, 3.86; 95% CI, 2.04–7.30; P <0.001) compared with <1 minute (RR, 1.77; 95% CI, 1.15–2.74; P =0.01). Notably, the risk of TE was also increased in patients with adjudicated atrial electrograms (RR, 3.60; 95% CI, 2.06–6.30; P <0.001) compared with nonadjudicated electrograms (RR, 2.05; 95% CI, 1.06–3.97; P =0.03), even when lower mean thresholds for detection were used. Conclusions: New-onset DDAT is common, affecting close to one quarter of all patients with implanted pacemakers or defibrillators. Adjudication of atrial electrograms further identifies at-risk patients, even when relatively short detection thresholds are used.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circep.117.005393

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

Metadata

Authors
Belkin, M. N., Soria, C. E., Waldo, A. L., Borleffs, C. J. W., Hayes, D. L., Tung, R., Singh, J. P., & Upadhyay, G. A.
Venue
Circulation: Arrhythmia and Electrophysiology
Published
2018-03
Volume
11
Issue
3
Pages
e005393-e005393
ISSN
  • 1941-3084 (ISSN-L)
  • 1941-3149
OpenAlex
W2793042064
Cited by
23
References
10
FWCI
2.24
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.