CoChat

STABLE-SR (Electrophysiological Substrate Ablation in the Left Atrium During Sinus Rhythm) for the Treatment of Nonparoxysmal Atrial Fibrillation: A Prospective, Multicenter Randomized Clinical Trial

Open access
Yang, Bing, Jiang, Chenyang, Lin, Yazhou, Yang, Gang, Chu, Huimin, Cai, Heng, Lu, Fengmin, Zhan, Xianzhang, Xu, Jian, Wang, Xinhua, Ching, Chi-Keong, Singh, Balbir, Kim, Young-Hoon, Chen, Minglong · 2017 · Circulation: Arrhythmia and Electrophysiology
Cited by 183

The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.

Abstract

Background: Circumferential pulmonary vein isolation (CPVI) alone or combined with adjuvant substrate modifications is unsatisfactory for atrial fibrillation (AF) control in nonparoxysmal AF patients. Ablation targeting the fibrotic areas after CPVI (STABLE-SR [Electrophysiological Substrate Ablation in the Left Atrium During Sinus Rhythm]) is a newly evolved substrate modification strategy. Methods and Results: In this multicenter, randomized clinical trial, 229 symptomatic nonparoxysmal AF patients were 1:1 randomized to STABLE-SR group (n=114) or conventional STEPWISE group (n=115). In the STABLE-SR group, after CPVI, cavotricuspid isthmus ablation and cardioversion to sinus rhythm, left atrial high-density mapping was performed. Areas with low-voltage and complex electrogram were further homogenized and eliminated, respectively. Dechanneling would be done if necessary. In the STEPWISE group, additional linear lesions and defragmentation were performed.The primary end point was freedom from documented atrial tachyarrhythmias for ≥30 s after a single ablation procedure without antiarrhythmic medications at 18 months. At 18 months, 74.0% of the patients in the STABLE-SR group and 71.5% in the STEPWISE group (hazard ratio, 0.78; 95% confidence interval, 0.47–1.29; P =0.325) achieved success according to intention-to-treat analysis. However, less procedure time (186.8±52.7 versus 210.5±48.0 minutes, P <0.001), reduced post-CPVI fluoroscopic time (11.0±7.8 versus 13.7±8.9 minutes, P =0.006), and shorter energy delivery time (60.1±25.1 versus 75.0±24.3 minutes, P <0.001) were observed in the STABLE-SR group compared with the STEPWISE group. Conclusions: STABLE-SR is a simplified, personalized, and effective ablation strategy in nonparoxysmal AF patients. More importantly, over 50% nonparoxysmal AF patients do not need further ablation beyond CPVI and therefore can avoid excessive ablation. Clinical Trial Registration: URL: http://www.clinicaltrials.gov . Unique identifier: NCT01761188.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circep.117.005405

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 183

Metadata

Authors
Yang, B., Jiang, C., Lin, Y., Yang, G., Chu, H., Cai, H., Lu, F., Zhan, X., Xu, J., Wang, X., Ching, C.-K., Singh, B., Kim, Y.-H., & Chen, M.
Venue
Circulation: Arrhythmia and Electrophysiology
Published
2017-11
Volume
10
Issue
11
ISSN
  • 1941-3084 (ISSN-L)
  • 1941-3149
OpenAlex
W2769934181
Cited by
183
References
28
FWCI
7.61
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.