The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Noninvasive Fractional Flow Reserve Derived From Computed Tomography Angiography for Coronary Lesions of Intermediate Stenosis Severity: Results From the DeFACTO Study
Abstract
Background—: Fractional flow reserve derived from computed tomography angiography (FFR CT ) is a noninvasive method for diagnosis of ischemic coronary lesions. To date, the diagnostic performance of FFR CT for lesions of intermediate stenosis severity remains unexamined. Methods and Results—: Among 407 vessels from 252 patients at 17 centers who underwent CT, FFR CT , invasive coronary angiography, and invasive FFR, we identified 150 vessels of intermediate stenosis by CT, defined as 30% to 69% stenosis. FFR CT , FFR, and CT were interpreted in blinded fashion by independent core laboratories. FFR CT and FFR ≤0.80 were considered hemodynamically significant, whereas CT stenosis ≥50% was considered obstructive. Diagnostic performance of FFR CT versus CT was assessed for accuracy, sensitivity, specificity, positive predictive values, and negative predictive values. Area under the receiver operating characteristic curve and net reclassification improvement were evaluated. For lesions of intermediate stenosis severity, accuracy, sensitivity, specificity, positive predictive value, and negative predictive value of FFR CT were 71%, 74%, 67%, 41%, and 90%, whereas accuracy, sensitivity, specificity, positive predictive value, and negative predictive value of CT stenosis were 63%, 34%, 72%, 27%, and 78%. FFR CT demonstrated superior discrimination compared with CT stenosis on per-patient (area under the receiver operating characteristic curve, 0.81 versus 0.50; P =0.0001) and per-vessel basis (area under the receiver operating characteristic curve, 0.79 versus 0.53; P <0.0001). FFR CT demonstrated significant reclassification of CT stenosis for lesion-specific ischemia (net reclassification improvement, 0.45; 95% confidence interval, 0.25–0.65; P =0.01). Conclusions—: FFR CT possesses high diagnostic performance for diagnosis of ischemic for lesions of intermediate stenosis severity. Notably, the high sensitivity and negative predictive value suggest the ability of FFR CT to effectively rule out intermediate lesions that cause ischemia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
DeLong, E. R., DeLong, D. M., & Clarke-Pearson, D. L. (1988) · Biometrics · doi:10.2307/2531595 · Cited by 22,649
Fractional Flow Reserve versus Angiography for Guiding Percutaneous Coronary Intervention
Tonino, P. A. L., De Bruyne, B., Pijls, N. H. J., Siebert, U., Ikeno, F., van `t Veer, M., Klauss, V., Manoharan, G., Engstrøm, T., Oldroyd, K. G., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0807611 · Cited by 4,260
Fractional Flow Reserve–Guided PCI versus Medical Therapy in Stable Coronary Disease
De Bruyne, B., Pijls, N. H. J., Kalesan, B., Barbato, E., Tonino, P. A. L., Piroth, Z., Jagic, N., Möbius-Winkler, S., Rioufol, G., Witt, N., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1205361 · Cited by 2,772
Measurement of Fractional Flow Reserve to Assess the Functional Severity of Coronary-Artery Stenoses
Pijls, N. H. J., de Bruyne, B., Peels, K., van der Voort, P. H., Bonnier, H. J. R. M., Bartunek, J., & Koolen, J. J. (1996) · New England Journal of Medicine · doi:10.1056/nejm199606273342604 · Cited by 2,321
Percutaneous Coronary Intervention of Functionally Nonsignificant Stenosis
Pijls, N. H. J., van Schaardenburgh, P., Manoharan, G., Boersma, E., Bech, J.-W., van’t Veer, M., Bär, F., Hoorntje, J., Koolen, J., Wijns, W., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.01.087 · Cited by 1,516
Diagnostic Accuracy of Fractional Flow Reserve From Anatomic CT Angiography
Min, J. K., Leipsic, J., Pencina, M. J., Berman, D. S., Koo, B.-K., van Mieghem, C., Erglis, A., Lin, F. Y., Dunning, A. M., Apruzzese, P., et al. (2012) · JAMA · doi:10.1001/2012.jama.11274 · Cited by 1,162
Self-citationBech, G. J. W., De Bruyne, B., Pijls, N. H. J., de Muinck, E. D., Hoorntje, J. C. A., Escaned, J., Stella, P. R., Boersma, E., Bartunek, J., Koolen, J. J., et al. (2001) · Circulation · doi:10.1161/01.cir.103.24.2928 · Cited by 911
Relation between Myocardial Blood Flow and the Severity of Coronary-Artery Stenosis
Uren, N. G., Melin, J. A., De Bruyne, B., Wijns, W., Baudhuin, T., & Camici, P. G. (1994) · New England Journal of Medicine · doi:10.1056/nejm199406233302503 · Cited by 881
Comprehensive Assessment of Coronary Artery Stenoses
Meijboom, W. B., Van Mieghem, C. A. G., van Pelt, N., Weustink, A., Pugliese, F., Mollet, N. R., Boersma, E., Regar, E., van Geuns, R. J., de Jaegere, P. J., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.05.024 · Cited by 637
Patient-Specific Modeling of Blood Flow and Pressure in Human Coronary Arteries
Kim, H. J., Vignon-Clementel, I. E., Coogan, J. S., Figueroa, C. A., Jansen, K. E., & Taylor, C. A. (2010) · Annals of Biomedical Engineering · doi:10.1007/s10439-010-0083-6 · Cited by 628
Cited by
(2014) · European Heart Journal · doi:10.1093/eurheartj/ehu278 · Cited by 4,314
2014 ESC/EACTS Guidelines on myocardial revascularization
Kolh, P., Windecker, S., Alfonso, F., Collet, J.-P., Cremer, J., Falk, V., Filippatos, G., Hamm, C., Head, S. J., Jüni, P., et al. (2014) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezu366 · Cited by 4,199
Outcomes of Anatomical versus Functional Testing for Coronary Artery Disease
Douglas, P. S., Hoffmann, U., Patel, M. R., Mark, D. B., Al-Khalidi, H. R., Cavanaugh, B., Cole, J., Dolor, R. J., Fordyce, C. B., Huang, M., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1415516 · Cited by 1,543
2014 ESC/EACTS Guidelines on myocardial revascularization
Windecker, S., Kolh, P., Alfonso, F., Collet, J.-P., Cremer, J., Falk, V., Filippatos, G., Hamm, C., Head, S. J., Jüni, P., et al. (2014) · Kardiologia Polska · doi:10.5603/kp.2014.0224 · Cited by 418
Coenen, A., Kim, Y.-H., Kruk, M., Tesche, C., De Geer, J., Kurata, A., Lubbers, M. L., Daemen, J., Itu, L., Rapaka, S., et al. (2018) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.117.007217 · Cited by 397
Metadata
- Authors
- Nakazato, R., Park, H.-B., Berman, D. S., Gransar, H., Koo, B.-K., Erglis, A., Lin, F. Y., Dunning, A. M., Budoff, M. J., Malpeso, J., Leipsic, J., & Min, J. K.
- Venue
- Circulation: Cardiovascular Imaging
- Published
- 2013-11
- Volume
- 6
- Issue
- 6
- Pages
- 881-889
- ISSN
- 1941-9651 (ISSN-L)
- 1942-0080
- OpenAlex
- W2548826879
- Cited by
- 272
- References
- 23
- FWCI
- 19.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Noninvasive Fractional Flow Reserve Derived From Computed Tomography Angiography for Coronary Lesions of Intermediate Stenosis Severity: Results From the DeFACTO Study. https://app.cochat.ai/papers/10.1161/circimaging.113.000297
- The paper
- Nakazato, R., Park, H.-B., Berman, D. S., Gransar, H., Koo, B.-K., Erglis, A., Lin, F. Y., Dunning, A. M., Budoff, M. J., Malpeso, J., Leipsic, J., & Min, J. K. (2013). Noninvasive Fractional Flow Reserve Derived From Computed Tomography Angiography for Coronary Lesions of Intermediate Stenosis Severity: Results From the DeFACTO Study. Circulation: Cardiovascular Imaging. https://doi.org/10.1161/circimaging.113.000297
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.