The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Transapical Transcatheter Aortic Valve Implantation in Humans: Initial Clinical Experience
Abstract
Background— Aortic valve replacement with cardiopulmonary bypass is currently the treatment of choice for symptomatic aortic stenosis but carries a significant risk of morbidity and mortality, particularly in patients with comorbidities. Recently, percutaneous transfemoral aortic valve implantation has been proposed as a viable alternative in selected patients. We describe our experience with a new, minimally invasive, catheter-based approach to aortic valve implantation via left ventricular apical puncture without cardiopulmonary bypass or sternotomy. Methods and Results— A left anterolateral intercostal incision is used to expose the left ventricular apex. Direct needle puncture of the apex allows introduction of a hemostatic sheath into the left ventricle. The valve prosthesis, constructed from a stainless steel stent with an attached trileaflet equine pericardial valve, is crimped onto a valvuloplasty balloon. The prosthetic valve and balloon catheter are passed over a wire into the left ventricle. Positioning within the aortic annulus is confirmed by fluoroscopy, aortography, and echocardiography. Rapid ventricular pacing is used to reduce cardiac output while the balloon is inflated, deploying the prosthesis within the annulus. Transapical aortic valve implantation was successfully performed in 7 patients in whom surgical risk was deemed excessive because of comorbidities. Echocardiographic median aortic valve area increased from 0.7±0.1 cm 2 (interquartile range) to 1.8±0.8 cm 2 (interquartile range). There were no intraprocedural deaths. At a follow up of 87±56 days, 6 of 7 patients remain alive and well. Conclusions— This initial experience suggests that transapical aortic valve implantation without cardiopulmonary bypass is feasible in selected patients with aortic stenosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bonow, R. O., Carabello, B. A., Chatterjee, K., de Leon, A. C., Faxon, D. P., Freed, M. D., Gaasch, W. H., Lytle, B. W., Nishimura, R. A., O’Gara, P. T., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.176857 · Cited by 8,495
European system for cardiac operative risk evaluation (EuroSCORE)
Nashef, S. A. M., Roques, F., Michel, P., Gauducheau, E., Lemeshow, S., & Salamon, R. (1999) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/s1010-7940(99)00134-7 · Cited by 3,362
Cribier, A., Eltchaninoff, H., Bash, A., Borenstein, N., Tron, C., Bauer, F., Derumeaux, G., Anselme, F., Laborde, F., & Leon, M. B. (2002) · Circulation · doi:10.1161/01.cir.0000047200.36165.b8 · Cited by 3,172
ACC/AHA guidelines for the management of patients with valvular heart disease
Bonow, R., Carabello, B., de Leon, A., Edmunds, L. H., Fedderly, B., Freed, M., Gaasch, W., McKay, C., Nishimura, R., O’Gara, P., et al. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00454-9 · Cited by 1,134
Percutaneous Aortic Valve Implantation Retrograde From the Femoral Artery
Webb, J. G., Chandavimol, M., Thompson, C. R., Ricci, D. R., Carere, R. G., Munt, B. I., Buller, C. E., Pasupati, S., & Lichtenstein, S. (2006) · Circulation · doi:10.1161/circulationaha.105.582882 · Cited by 900
Self-citationROSS, J., & BRAUNWALD, E. (1968) · Circulation · doi:10.1161/01.cir.38.1s5.v-61 · Cited by 725
Treatment of Calcific Aortic Stenosis With the Percutaneous Heart Valve
Cribier, A., Eltchaninoff, H., Tron, C., Bauer, F., Agatiello, C., Nercolini, D., Tapiero, S., Litzler, P.-Y., Bessou, J.-P., & Babaliaros, V. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.01.049 · Cited by 715
Cribier, A., Eltchaninoff, H., Tron, C., Bauer, F., Agatiello, C., Sebagh, L., Bash, A., Nusimovici, D., Litzler, P. Y., Bessou, J.-P., et al. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.11.026 · Cited by 644
The effect of aortic valve replacement on survival.
Schwarz, F., Baumann, P., Manthey, J., Hoffmann, M., Schuler, G., Mehmel, H. C., Schmitz, W., & Kübler, W. (1982) · Circulation · doi:10.1161/01.cir.66.5.1105 · Cited by 584
Nashef, S. (2002) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/s1010-7940(02)00208-7 · Cited by 546
ANDERSEN, H. R., KNUDSEN, L. L., & HASENKAM, J. M. (1992) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a060238 · Cited by 491
Otto, C. M., Mickel, M. C., Kennedy, J. W., Alderman, E. L., Bashore, T. M., Block, P. C., Brinker, J. A., Diver, D., Ferguson, J., & Holmes, D. R. (1994) · Circulation · doi:10.1161/01.cir.89.2.642 · Cited by 476
Balloon aortic valvuloplasty in adults: Failure of procedure to improve long-term survival
Lieberman, E. B., Bashore, T. M., Hermiller, J. B., Wilson, J. S., Pieper, K. S., Keeler, G. P., Pierce, C. H., Kisslo, K. B., Harrison, J. K., & Davidson, C. J. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)00363-0 · Cited by 299
Grube, E., Laborde, J. C., Zickmann, B., Gerckens, U., Felderhoff, T., Sauren, B., Bootsveld, A., Buellesfeld, L., & Iversen, S. (2005) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.20544 · Cited by 251
Cardiac surgery in octogenarians. Peri-operative outcome and long-term results
Kolh, P. (2001) · European Heart Journal · doi:10.1053/euhj.2000.2443 · Cited by 217
Quality of Life After Aortic Valve Replacement at the Age of >80 Years
Sundt, T. M., Bailey, M. S., Moon, M. R., Mendeloff, E. N., Huddleston, C. B., Pasque, M. K., Barner, H. B., & Gay, W. A. (2000) · Circulation · doi:10.1161/01.cir.102.suppl_3.iii-70 · Cited by 208
Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis
Cribier, A. G., Eltchaninoff, H., & Bash, A. (2003) · ACC Current Journal Review · doi:10.1016/s1062-1458(03)00094-1 · Cited by 151
O’Neill, W. W., & The Mansfield Scientific Aortic Valvuloplasty Registry Investigators (1991) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(91)90727-q · Cited by 110
Aortic valve replacement in geriatric patients: determinants of in-hospital mortality
Bloomstein, L. Z., Gielchinsky, I., Bernstein, A. D., Parsonnet, V., Saunders, C. R., Karanam, R., & Graves, B. (2001) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(00)02326-2 · Cited by 94
Swan, H., Saarinen, K., KONTULA, K. K., Toivonen, L. K., & Viitasalo, M. T. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00248-4 · Cited by 69
Core curriculum for interventional cardiology: Percutaneous valvuloplasty
Feldman, T. E. (2003) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.10598 · Cited by 26
Quality of Life After Aortic Valve Replacement at the Age of >80 Years
Sundt, T. M., Bailey, M. S., Moon, M. R., Mendeloff, E. N., Huddleston, C. B., Pasque, M. K., Barner, H. B., & Gay, W. A. (2000) · Circulation · doi:10.1161/circ.102.suppl_3.iii-70 · Cited by 23
Closed heart surgery: Back to the future
Lichtenstein, S. V. (2006) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2006.01.025 · Cited by 22
Self-citationAortenklappenersatz bei 80- und über 80-jährigen
Mortasawi, A., Gehle, S., Schröder, T., Ennker, I. C., Rosendahl, U., Dalladaku, F., Bauer, S., Albert, A., & Ennker, J. (2000) · Zeitschrift für Gerontologie und Geriatrie · doi:10.1007/s003910070017 · Cited by 14
Percutaneous aortic valve implantation: A case report
Chandavimol, M., McClure, S. J., Carere, R. G., Thompson, C., Ricci, D. R., Mackay, M., & Webb, J. G. (2006) · Canadian Journal of Cardiology · doi:10.1016/s0828-282x(06)70954-0 · Cited by 13
Self-citation
Cited by
Grube, E., Schuler, G., Buellesfeld, L., Gerckens, U., Linke, A., Wenaweser, P., Sauren, B., Mohr, F.-W., Walther, T., Zickmann, B., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.04.047 · Cited by 959
Carabello, B. A., & Paulus, W. J. (2009) · The Lancet · doi:10.1016/s0140-6736(09)60211-7 · Cited by 818
Prosthetic Heart Valves: Selection of the Optimal Prosthesis and Long-Term Management
Pibarot, P., & Dumesnil, J. G. (2009) · Circulation · doi:10.1161/circulationaha.108.778886 · Cited by 786
Vahanian, A., Alfieri, O., Al-Attar, N., Antunes, M., Bax, J., Cormier, B., Cribier, A., De Jaegere, P., Fournial, G., Kappetein, A. P., et al. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn183 · Cited by 719
Transapical Minimally Invasive Aortic Valve Implantation: Multicenter Experience
Walther, T., Simon, P., Dewey, T., Wimmer-Greinecker, G., Falk, V., Kasimir, M. T., Doss, M., Borger, M. A., Schuler, G., Glogar, D., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.677237 · Cited by 618
Metadata
- Authors
- Lichtenstein, S. V., Cheung, A., Ye, J., Thompson, C. R., Carere, R. G., Pasupati, S., & Webb, J. G.
- Venue
- Circulation
- Published
- 2006-08-08
- Volume
- 114
- Issue
- 6
- Pages
- 591-596
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2124968972
- Cited by
- 561
- References
- 25
- FWCI
- 41.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.