The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Incomplete Stent Apposition and Very Late Stent Thrombosis After Drug-Eluting Stent Implantation
Abstract
Background— Stent thrombosis may occur late after drug-eluting stent (DES) implantation, and its cause remains unknown. The present study investigated differences of the stented segment between patients with and without very late stent thrombosis with the use of intravascular ultrasound. Methods and Results— Since January 2004, patients presenting with very late stent thrombosis (>1 year) after DES implantation underwent intravascular ultrasound. Findings in patients with very late stent thrombosis were compared with intravascular ultrasound routinely obtained 8 months after DES implantation in 144 control patients, who did not experience stent thrombosis for ≥2 years. Very late stent thrombosis was encountered in 13 patients at a mean of 630±166 days after DES implantation. Compared with DES controls, patients with very late stent thrombosis had longer lesions (23.9±16.0 versus 13.3±7.9 mm; P <0.001) and stents (34.6±22.4 versus 18.6±9.5 mm; P <0.001), more stents per lesion (1.6±0.9 versus 1.1±0.4; P <0.001), and stent overlap (39% versus 8%; P <0.001). Vessel cross-sectional area was similar for the reference segment (cross-sectional area of the external elastic membrane: 18.9±6.9 versus 20.4±7.2 mm 2 ; P =0.46) but significantly larger for the in-stent segment (28.6±11.9 versus 20.1±6.7 mm 2 ; P =0.03) in very late stent thrombosis patients compared with DES controls. Incomplete stent apposition was more frequent (77% versus 12%; P <0.001) and maximal incomplete stent apposition area was larger (8.3±7.5 versus 4.0±3.8 mm 2 ; P =0.03) in patients with very late stent thrombosis compared with controls. Conclusions— Incomplete stent apposition is highly prevalent in patients with very late stent thrombosis after DES implantation, suggesting a role in the pathogenesis of this adverse event.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Iakovou, I. (2005) · JAMA · doi:10.1001/jama.293.17.2126 · Cited by 3,132
Pathology of Drug-Eluting Stents in Humans
Joner, M., Finn, A. V., Farb, A., Mont, E. K., Kolodgie, F. D., Ladich, E., Kutys, R., Skorija, K., Gold, H. K., & Virmani, R. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.03.042 · Cited by 2,744
Virmani, R., Guagliumi, G., Farb, A., Musumeci, G., Grieco, N., Motta, T., Mihalcsik, L., Tespili, M., Valsecchi, O., & Kolodgie, F. D. (2004) · Circulation · doi:10.1161/01.cir.0000116202.41966.d4 · Cited by 1,469
Late thrombosis in drug-eluting coronary stents after discontinuation of antiplatelet therapy
McFadden, E. P., Stabile, E., Regar, E., Cheneau, E., Ong, A. T., Kinnaird, T., Suddath, W. O., Weissman, N. J., Torguson, R., Kent, K. M., et al. (2004) · The Lancet · doi:10.1016/s0140-6736(04)17275-9 · Cited by 1,436
Late Angiographic Stent Thrombosis (LAST) Events With Drug-Eluting Stents
Ong, A. T. L., McFadden, E. P., Regar, E., de Jaegere, P. P. T., van Domburg, R. T., & Serruys, P. W. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.02.086 · Cited by 663
Kuchulakanti, P. K., Chu, W. W., Torguson, R., Ohlmann, P., Rha, S.-W., Clavijo, L. C., Kim, S.-W., Bui, A., Gevorkian, N., Xue, Z., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.600155 · Cited by 639
Hypersensitivity Cases Associated With Drug-Eluting Coronary Stents
Nebeker, J. R., Virmani, R., Bennett, C. L., Hoffman, J. M., Samore, M. H., Alvarez, J., Davidson, C. J., McKoy, J. M., Raisch, D. W., Whisenant, B. K., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.07.071 · Cited by 610
Sirolimus-Eluting and Paclitaxel-Eluting Stents for Coronary Revascularization
Windecker, S., Remondino, A., Eberli, F. R., Jüni, P., Räber, L., Wenaweser, P., Togni, M., Billinger, M., Tüller, D., Seiler, C., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa051175 · Cited by 593
Self-citationLate Thrombosis After Radiation: Sitting on a Time Bomb
Waksman, R. (1999) · Circulation · doi:10.1161/01.cir.100.8.780 · Cited by 175
Cited by
Zinc Exhibits Ideal Physiological Corrosion Behavior for Bioabsorbable Stents
Bowen, P. K., Drelich, J., & Goldman, J. (2013) · Advanced Materials · doi:10.1002/adma.201300226 · Cited by 928
In-Stent Restenosis in the Drug-Eluting Stent Era
Dangas, G. D., Claessen, B. E., Caixeta, A., Sanidas, E. A., Mintz, G. S., & Mehran, R. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.07.028 · Cited by 803
Kolandaivelu, K., Swaminathan, R., Gibson, W. J., Kolachalama, V. B., Nguyen-Ehrenreich, K.-L., Giddings, V. L., Coleman, L., Wong, G. K., & Edelman, E. R. (2011) · Circulation · doi:10.1161/circulationaha.110.003210 · Cited by 802
Nakazawa, G., Finn, A. V., Joner, M., Ladich, E., Kutys, R., Mont, E. K., Gold, H. K., Burke, A. P., Kolodgie, F. D., & Virmani, R. (2008) · Circulation · doi:10.1161/circulationaha.107.762047 · Cited by 611
Park, S.-J., Kim, Y.-H., Park, D.-W., Lee, S.-W., Kim, W.-J., Suh, J., Yun, S.-C., Lee, C. W., Hong, M.-K., Lee, J.-H., et al. (2009) · Circulation: Cardiovascular Interventions · doi:10.1161/circinterventions.108.799494 · Cited by 522
Garg, S., & Serruys, P. W. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.06.007 · Cited by 501
Otsuka, F., Vorpahl, M., Nakano, M., Foerst, J., Newell, J. B., Sakakura, K., Kutys, R., Ladich, E., Finn, A. V., Kolodgie, F. D., et al. (2014) · Circulation · doi:10.1161/circulationaha.113.001790 · Cited by 491
Incidence and Correlates of Drug-Eluting Stent Thrombosis in Routine Clinical Practice
Wenaweser, P., Daemen, J., Zwahlen, M., van Domburg, R., Jüni, P., Vaina, S., Hellige, G., Tsuchida, K., Morger, C., Boersma, E., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.07.006 · Cited by 481
Self-citationCook, S., Ladich, E., Nakazawa, G., Eshtehardi, P., Neidhart, M., Vogel, R., Togni, M., Wenaweser, P., Billinger, M., Seiler, C., et al. (2009) · Circulation · doi:10.1161/circulationaha.109.854398 · Cited by 480
Self-citationYang, H., Wang, C., Liu, C., Chen, H., Wu, Y., Han, J., Jia, Z., Lin, W., Zhang, D., Li, W., et al. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.08.022 · Cited by 399
Buccheri, D., Piraino, D., Andolina, G., & Cortese, B. (2016) · Journal of Thoracic Disease · doi:10.21037/jtd.2016.10.93 · Cited by 397
Räber, L., Magro, M., Stefanini, G. G., Kalesan, B., van Domburg, R. T., Onuma, Y., Wenaweser, P., Daemen, J., Meier, B., Jüni, P., et al. (2012) · Circulation · doi:10.1161/circulationaha.111.058560 · Cited by 374
Self-citationHolmes, D. R., Kereiakes, D. J., Garg, S., Serruys, P. W., Dehmer, G. J., Ellis, S. G., Williams, D. O., Kimura, T., & Moliterno, D. J. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.07.016 · Cited by 367
Serruys, P. W., Farooq, V., Kalesan, B., de Vries, T., Buszman, P., Linke, A., Ischinger, T., Klauss, V., Eberli, F., Wijns, W., et al. (2013) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2013.04.011 · Cited by 331
Self-citationNakazawa, G., Finn, A. V., Vorpahl, M., Ladich, E. R., Kolodgie, F. D., & Virmani, R. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.05.066 · Cited by 299
Role of high shear rate in thrombosis
Casa, L. D. C., Deaton, D. H., & Ku, D. N. (2015) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2014.12.050 · Cited by 295
Hassan, A. K. M., Bergheanu, S. C., Stijnen, T., van der Hoeven, B. L., Snoep, J. D., Plevier, J. W. M., Schalij, M. J., & Wouter Jukema, J. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehn553 · Cited by 290
Novel high-strength, low-alloys Zn-Mg (< 0.1 wt% Mg) and their arterial biodegradation
Jin, H., Zhao, S., Guillory, R., Bowen, P. K., Yin, Z., Griebel, A., Schaffer, J., Earley, E. J., Goldman, J., & Drelich, J. W. (2018) · Materials Science and Engineering: C · doi:10.1016/j.msec.2017.11.021 · Cited by 271
Curcio, A., Torella, D., & Indolfi, C. (2011) · Circulation Journal · doi:10.1253/circj.cj-11-0366 · Cited by 262
Combating medical device fouling
Harding, J. L., & Reynolds, M. M. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2013.12.004 · Cited by 261
Long-term surveillance of zinc implant in murine artery: Surprisingly steady biocorrosion rate
Drelich, A. J., Zhao, S., Guillory, R. J., Drelich, J. W., & Goldman, J. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.05.045 · Cited by 188
Bioresorbable Stents: Is This Where We Are Headed?
Wayangankar, S. A., & Ellis, S. G. (2015) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2015.08.011 · Cited by 18
Metadata
- Authors
- Cook, S., Wenaweser, P., Togni, M., Billinger, M., Morger, C., Seiler, C., Vogel, R., Hess, O., Meier, B., & Windecker, S.
- Venue
- Circulation
- Published
- 2007-05-08
- Volume
- 115
- Issue
- 18
- Pages
- 2426-2434
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2129811129
- Cited by
- 839
- References
- 9
- FWCI
- 71.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.