The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Degradation and Healing Characteristics of Small-Diameter Poly(ε-Caprolactone) Vascular Grafts in the Rat Systemic Arterial Circulation
Open accessAbstract
Background— Long-term patency of conventional synthetic grafts is unsatisfactory below a 6-mm internal diameter. Poly(ε-caprolactone) (PCL) is a promising biodegradable polymer with a longer degradation time. We aimed to evaluate in vivo healing and degradation characteristics of small-diameter vascular grafts made of PCL nanofibers compared with expanded polytetrafluoroethylene (ePTFE) grafts. Methods and Results— We prepared 2-mm–internal diameter grafts by electrospinning using PCL (M n =80 000 g/mol). Either PCL (n=15) or ePTFE (n=15) grafts were implanted into 30 rats. Rats were followed up for 24 weeks. At the conclusion of the follow-up period, patency and structural integrity were evaluated by digital subtraction angiography. The abdominal aorta, including the graft, was harvested and investigated under light microscopy. Endothelial coverage, neointima formation, and transmural cellular ingrowth were measured by computed histomorphometry. All animals survived until the end of follow-up, and all grafts were patent in both groups. Digital subtraction angiography revealed no stenosis in the PCL group but stenotic lesions in 1 graft at 18 weeks (40%) and in another graft at 24 weeks (50%) in the ePTFE group. None of the grafts showed aneurysmal dilatation. Endothelial coverage was significantly better in the PCL group. Neointimal formation was comparable between the 2 groups. Macrophage and fibroblast ingrowth with extracellular matrix formation and neoangiogenesis were better in the PCL group. After 12 weeks, foci of chondroid metaplasia located in the neointima of PCL grafts were observed in all samples. Conclusions— Small-diameter PCL grafts represent a promising alternative for the future because of their better healing characteristics compared with ePTFE grafts. Faster endothelialization and extracellular matrix formation, accompanied by degradation of graft fibers, seem to be the major advantages. Further evaluation of degradation and graft healing characteristics may potentially lead to the clinical use of such grafts for revascularization procedures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biodegradable polymers as biomaterials
Nair, L. S., & Laurencin, C. T. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.05.017 · Cited by 4,416
Functional Arteries Grown in Vitro
Niklason, L. E., Gao, J., Abbott, W. M., Hirschi, K. K., Houser, S., Marini, R., & Langer, R. (1999) · Science · doi:10.1126/science.284.5413.489 · Cited by 1,766
The in vivo degradation, absorption and excretion of PCL-based implant
Sun, H., Mei, L., Song, C., Cui, X., & Wang, P. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.09.019 · Cited by 976
Pham, Q. P., Sharma, U., & Mikos, A. G. (2006) · Biomacromolecules · doi:10.1021/bm060680j · Cited by 956
The effect of scaffold degradation rate on three-dimensional cell growth and angiogenesis
Sung, H.-J., Meredith, C., Johnson, C., & Galis, Z. S. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2004.01.066 · Cited by 804
Biomaterials in the development and future of vascular grafts
Xue, L., & Greisler, H. P. (2003) · Journal of Vascular Surgery · doi:10.1067/mva.2003.88 · Cited by 519
Vaz, C. M., van Tuijl, S., Bouten, C. V. C., & Baaijens, F. P. T. (2005) · Acta Biomaterialia · doi:10.1016/j.actbio.2005.06.006 · Cited by 459
The intracellular degradation of poly(ε‐caprolactone)
Woodward, S. C., Brewer, P. S., Moatamed, F., Schindler, A., & Pitt, C. G. (1985) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820190408 · Cited by 380
Bölgen, N., Menceloğlu, Y. Z., Acatay, K., Vargel, İ., & Pişkin, E. (2005) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/156856205774576655 · Cited by 311
Evidence of Hypoxic Areas Within the Arterial Wall In Vivo
Björnheden, T., Levin, M., Evaldsson, M., & Wiklund, O. (1999) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.19.4.870 · Cited by 286
Cited by
The return of a forgotten polymer—Polycaprolactone in the 21st century
Woodruff, M. A., & Hutmacher, D. W. (2010) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2010.04.002 · Cited by 4,033
A Comparative Review of Natural and Synthetic Biopolymer Composite Scaffolds
Reddy, M. S. B., Ponnamma, D., Choudhary, R., & Sadasivuni, K. K. (2021) · Polymers · doi:10.3390/polym13071105 · Cited by 1,104
Zheng, W., Wang, Z., Song, L., Zhao, Q., Zhang, J., Li, D., Wang, S., Han, J., Zheng, X.-L., Yang, Z., et al. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2011.12.047 · Cited by 288
An alternative solvent system for the steady state electrospinning of polycaprolactone
Van der Schueren, L., De Schoenmaker, B., Kalaoglu, Ö. I., & De Clerck, K. (2011) · European Polymer Journal · doi:10.1016/j.eurpolymj.2011.02.025 · Cited by 270
Substrates for cardiovascular tissue engineering
Bouten, C. V. C., Dankers, P. Y. W., Driessen-Mol, A., Pedron, S., Brizard, A. M. A., & Baaijens, F. P. T. (2011) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2011.01.007 · Cited by 261
Metadata
- Authors
- Pektok, E., Nottelet, B., Tille, J.-C., Gurny, R., Kalangos, A., Moeller, M., & Walpoth, B. H.
- Venue
- Circulation
- Published
- 2008-12-09
- Volume
- 118
- Issue
- 24
- Pages
- 2563-2570
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2042233722
- Cited by
- 358
- References
- 25
- FWCI
- 8.24
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Degradation and Healing Characteristics of Small-Diameter Poly(ε-Caprolactone) Vascular Grafts in the Rat Systemic Arterial Circulation. https://app.cochat.ai/papers/10.1161/circulationaha.108.795732
- The paper
- Pektok, E., Nottelet, B., Tille, J.-C., Gurny, R., Kalangos, A., Moeller, M., & Walpoth, B. H. (2008). Degradation and Healing Characteristics of Small-Diameter Poly(ε-Caprolactone) Vascular Grafts in the Rat Systemic Arterial Circulation. Circulation. https://doi.org/10.1161/circulationaha.108.795732
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.