The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Permanent Leadless Cardiac Pacing: Results of the LEADLESS Trial
Open accessAbstract
Background—: Conventional cardiac pacemakers are associated with several potential short- and long-term complications related to either the transvenous lead or subcutaneous pulse generator. We tested the safety and clinical performance of a novel, completely self-contained leadless cardiac pacemaker. Methods and Results—: The primary safety end point was freedom from complications at 90 days. Secondary performance end points included implant success rate, implant time, and measures of device performance (pacing/sensing thresholds and rate-responsive performance). The mean age of the patient cohort (n=33) was 77±8 years, and 67% of the patients were male (n=22/33). The most common indication for cardiac pacing was permanent atrial fibrillation with atrioventricular block (n=22, 67%). The implant success rate was 97% (n=32). Five patients (15%) required the use of >1 leadless cardiac pacemaker during the procedure. One patient developed right ventricular perforation and cardiac tamponade during the implant procedure, and eventually died as the result of a stroke. The overall complication-free rate was 94% (31/33). After 3 months of follow-up, the measures of pacing performance (sensing, impedance, and pacing threshold) either improved or were stable within the accepted range. Conclusions—: In a prospective nonrandomized study, a completely self-contained, single-chamber leadless cardiac pacemaker has shown to be safe and feasible. The absence of a transvenous lead and subcutaneous pulse generator could represent a paradigm shift in cardiac pacing. Clinical Trial Registration—: URL: http://clinicaltrials.gov . Unique identifier: NCT01700244.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
MOND, H. G., & PROCLEMER, A. (2011) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2011.03150.x · Cited by 984
An Entirely Subcutaneous Implantable Cardioverter–Defibrillator
Bardy, G. H., Smith, W. M., Hood, M. A., Crozier, I. G., Melton, I. C., Jordaens, L., Theuns, D., Park, R. E., Wright, D. J., Connelly, D. T., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa0909545 · Cited by 780
Self-citationUdo, E. O., Zuithoff, N. P. A., van Hemel, N. M., de Cock, C. C., Hendriks, T., Doevendans, P. A., & Moons, K. G. M. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2011.12.014 · Cited by 597
Pacemaker or Defibrillator Surgery without Interruption of Anticoagulation
Birnie, D. H., Healey, J. S., Wells, G. A., Verma, A., Tang, A. S., Krahn, A. D., Simpson, C. S., Ayala-Paredes, F., Coutu, B., Leiria, T. L. L., et al. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1302946 · Cited by 579
Bohnen, M., Stevenson, W. G., Tedrow, U. B., Michaud, G. F., John, R. M., Epstein, L. M., Albert, C. M., & Koplan, B. A. (2011) · Heart Rhythm · doi:10.1016/j.hrthm.2011.05.017 · Cited by 274
Haghjoo, M., Nikoo, M. H., Fazelifar, A. F., Alizadeh, A., Emkanjoo, Z., & Sadr-Ameli, M. A. (2007) · EP Europace · doi:10.1093/europace/eum019 · Cited by 195
Hauser, R. G., Hayes, D. L., Kallinen, L. M., Cannom, D. S., Epstein, A. E., Almquist, A. K., Song, S. L., Tyers, G. F. O., Vlay, S. C., & Irwin, M. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2006.10.009 · Cited by 165
Totally self-contained intracardiac pacemaker
Spickler, J. W., Rasor, N. S., Kezdi, P., Misra, S. N., Robins, K. E., & LeBoeuf, C. (1970) · Journal of Electrocardiology · doi:10.1016/s0022-0736(70)80059-0 · Cited by 145
Tobin, K., Stewart, J. R., Westveer, D. C., & Frumin, H. (2000) · The American Journal of Cardiology · doi:10.1016/s0002-9149(99)00861-9 · Cited by 142
Al‐Mohaissen, M. A., & Chan, K. L. (2012) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2011.11.020 · Cited by 121
Recommendations from the Heart Rhythm Society Task Force on Lead Performance Policies and Guidelines
Maisel, W. H., Hauser, R. G., Hammill, S. C., Hauser, R. G., Ellenbogen, K. A., Epstein, A. E., Hayes, D. L., Alpert, J. S., Berger, R. D., Curtis, A. B., et al. (2009) · Heart Rhythm · doi:10.1016/j.hrthm.2009.04.024 · Cited by 114
Kirkfeldt, R. E., Johansen, J. B., Nohr, E. A., Møller, M., Arnsbo, P., & Nielsen, J. C. (2011) · Heart Rhythm · doi:10.1016/j.hrthm.2011.04.014 · Cited by 112
HRS/ACCF Expert Consensus Statement on Pacemaker Device and Mode Selection
Gillis, A. M., Russo, A. M., Ellenbogen, K. A., Swerdlow, C. D., Olshansky, B., Al‐Khatib, S. M., Beshai, J. F., McComb, J. M., Nielsen, J. C., Philpott, J. M., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.06.011 · Cited by 104
Auricchio, A., Delnoy, P.-P., Regoli, F., Seifert, M., Markou, T., Butter, C., & for the collaborative study group (2013) · Europace · doi:10.1093/europace/eut124 · Cited by 94
GAMMAGE, M. D., Lieberman, R. A., Yee, R. K., Manolis, A. S., Compton, S. J., Khazen, C. S., Schaaf, K., OLESON, K. A., & Crossley, G. H. (2006) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2006.00452.x · Cited by 86
First Human Demonstration of Cardiac Stimulation With Transcutaneous Ultrasound Energy Delivery
Lee, K. L., Lau, C., Tse, H., Echt, D. S., Heaven, D., Smith, W., & Hood, M. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.04.081 · Cited by 79
Leadless Pacing of the Heart Using Induction Technology: A Feasibility Study
Wieneke, H., Konorza, T. F. M., Erbel, R. M., & Kisker, E. (2009) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2008.02200.x · Cited by 58
Evaluation of six minute walking test in patients with single chamber rate responsive pacemakers.
Provenier, F., & Jordaens, L. J. L. M. (1994) · Heart · doi:10.1136/hrt.72.2.192 · Cited by 37
In the wireless era: leadless pacing
Lee, K. L. (2010) · Expert Review of Cardiovascular Therapy · doi:10.1586/erc.09.168 · Cited by 16
The leadless ultrasonic pacemaker: A sound idea?
Benditt, D. G., Goldstein, M., & Belalcazar, A. (2009) · Heart Rhythm · doi:10.1016/j.hrthm.2009.04.006 · Cited by 15
Research works printed but not linked: 4
- Vardas PE, Politopoulos C, Manios E, Parthenakis F, Tsagarkis C. A miniature pacemaker introduced intravenously and implanted endocardially. Preliminary findings from an experimental study. Eur J Card Pacing Electrophysiol. 1991;1:1–47.
- 10.3109/03091908309041220 · doi:10.3109/03091908309041220
- 10.1161/01.CIR.73.6.1206 · doi:10.1161/01.cir.73.6.1206
- 10.1111/j.1540-8159.2000.tb00858.x · doi:10.1111/j.1540-8159.2000.tb00858.x
Cited by
Kusumoto, F. M., Schoenfeld, M. H., Wilkoff, B. L., Berul, C. I., Birgersdotter-Green, U. M., Carrillo, R., Cha, Y.-M., Clancy, J., Deharo, J.-C., Ellenbogen, K. A., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.09.001 · Cited by 1,199
Percutaneous Implantation of an Entirely Intracardiac Leadless Pacemaker
Reddy, V. Y., Exner, D. V., Cantillon, D. J., Doshi, R., Bunch, T. J., Tomassoni, G. F., Friedman, P. A., Estes, N. A. M., Ip, J., Niazi, I., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1507192 · Cited by 539
Self-citationPermanent Leadless Cardiac Pacemaker Therapy: A Comprehensive Review
Tjong, F. V. Y., & Reddy, V. Y. (2017) · Circulation · doi:10.1161/circulationaha.116.025037 · Cited by 228
Self-citationNext-generation pacemakers: from small devices to biological pacemakers
Cingolani, E., Goldhaber, J. I., & Marbán, E. (2018) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2017.165 · Cited by 194
Chinitz, L., Ritter, P., Khelae, S. K., Iacopino, S., Garweg, C., Grazia-Bongiorni, M., Neuzil, P., Johansen, J. B., Mont, L., Gonzalez, E., et al. (2018) · Heart Rhythm · doi:10.1016/j.hrthm.2018.05.004 · Cited by 170
Self-citation
Metadata
- Authors
- Reddy, V. Y., Knops, R. E., Sperzel, J., Miller, M. A., Petru, J., Simon, J., Sediva, L., de Groot, J. R., Tjong, F. V. Y., Jacobson, P., Ostrosff, A., Dukkipati, S. R., Koruth, J. S., Wilde, A. A. M., Kautzner, J., & Neuzil, P.
- Venue
- Circulation
- Published
- 2014-04-08
- Volume
- 129
- Issue
- 14
- Pages
- 1466-1471
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W1997996984
- Cited by
- 308
- References
- 20
- FWCI
- 23.38
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.