A Three-Arm Randomized Trial of Different Renal Denervation Devices and Techniques in Patients With Resistant Hypertension (RADIOSOUND-HTN)

Open access
Fengler, Karl, Rommel, Karl-Philipp, Blazek, Stephan, Besler, Christian, Hartung, Philipp, von Roeder, Maximilian, Petzold, Martin, Winkler, Sindy, Höllriegel, Robert, Desch, Steffen, Thiele, Holger, Lurz, Philipp · 2019 · Circulation
Cited by 203

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

Background: Both radiofrequency and ultrasound endovascular renal sympathetic denervation (RDN) have proven clinical efficacy for the treatment of hypertension. We performed a head-to-head comparison of these technologies. Methods: Patients with resistant hypertension were randomly assigned in a 1:1:1 manner to receive either treatment with (1) radiofrequency RDN of the main renal arteries; (2) radiofrequency RDN of the main renal arteries, side branches, and accessories; or (3) an endovascular ultrasound–based RDN of the main renal artery. The primary end point was change in systolic daytime ambulatory blood pressure at 3 months. Results: Between June 2015 and June 2018, 120 patients were enrolled (mean age, 64±9 years±SD; mean daytime blood pressure, 153/86±12/13 mm Hg). Of these, 39 were randomly assigned to radiofrequency main renal artery ablation, 39 to combined radiofrequency ablation of the main artery and branches, and 42 to ultrasound-based treatment. Baseline daytime blood pressure, clinical characteristics, and treatment were well balanced between the groups. At 3 months, systolic daytime ambulatory blood pressure decreased by 9.5±12.3 mm Hg ( P <0.001) in the whole cohort. Although blood pressure was significantly more reduced in the ultrasound ablation group than in the radiofrequency ablation group of the main renal artery (–13.2±13.7 versus –6.5±10.3 mm Hg; mean difference, –6.7 mm Hg; global P =0.038 by ANOVA, adjusted P =0.043), no significant difference was found between the radiofrequency ablation groups (–8.3±11.7 mm Hg for additional side branch ablation; mean difference, –1.8 mm Hg; adjusted P >0.99). Similarly, the blood pressure reduction was not found to be significantly different between the ultrasound and the side branch ablation groups. Frequencies of blood pressure response ≥5 mm Hg were not significantly different (global P =0.77). Conclusions: In patients with resistant hypertension, endovascular ultrasound–based RDN was found to be superior to radiofrequency ablation of the main renal arteries only, whereas a combined approach of radiofrequency ablation of the main arteries, accessories, and side branches was not. Clinical Trial Registration: URL: https://www.clinicaltrials.gov . Unique identifier: NCT02920034.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.118.037654

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 203

Metadata

Authors
Fengler, K., Rommel, K.-P., Blazek, S., Besler, C., Hartung, P., von Roeder, M., Petzold, M., Winkler, S., Höllriegel, R., Desch, S., Thiele, H., & Lurz, P.
Venue
Circulation
Published
2019-01-29
Volume
139
Issue
5
Pages
590-600
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2893074865
Cited by
203
References
7
FWCI
16.30
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.