Changes in Home Versus Clinic Blood Pressure With Antihypertensive Treatments: A Meta-Analysis
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
Home blood pressure (HBP) monitoring is recommended for assessing the effects of antihypertensive treatment, but it is not clear how the treatment-induced changes in HBP compare with the changes in clinic blood pressure (CBP). We searched PubMed using the terms “home or self-measured blood pressure,” and selected articles in which the changes in CBP and HBP (using the upper arm oscillometric method) induced by antihypertensive drugs were presented. We performed a systematic review of 30 articles published before March 2008 that included a total of 6794 subjects. As there was significant heterogeneity in most of the outcomes, a random effects model was used for the meta-analyses. The mean changes (±SE) in CBP and HBP (systolic/diastolic) were −15.2±0.03/−10.3±0.03 mm Hg and −12.2±0.04/−8.0±0.04 mm Hg respectively, although there were wide varieties of differences in the reduction between HBP and CBP. The reductions in CBP were correlated with those of HBP (systolic BP; r =0.66, B=0.48, diastolic BP; r =0.71, B=0.52, P <0.001). In 7 studies that also included 24-hour BP monitoring, the reduction of HBP was greater than that of 24-hour BP in systolic (HBP; −12.6±0.06 mm Hg, 24-hour BP; −11.9±0.04 mm Hg, P <0.001). In 5 studies that included daytime and nighttime systolic BP separately, HBP decreased 15% more than daytime ambulatory BP and 30% more than nighttime ambulatory BP. In conclusion, HBP falls ≈20% less than CBP with antihypertensive treatments. Daytime systolic BP falls 15% less and nighttime systolic BP falls 30% less than home systolic BP.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Circulation · doi:10.1161/01.cir.0000154900.76284.f6 · Cited by 3,985
Self-citationPickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Hypertension · doi:10.1161/01.hyp.0000150859.47929.8e · Cited by 2,051
Self-citationO'Brien, E., Asmar, R., Beilin, L., Imai, Y., Mallion, J.-M., Mancia, G., Mengden, T., Myers, M., Padfield, P., Palatini, P., et al. (2003) · Journal of Hypertension · doi:10.1097/00004872-200305000-00001 · Cited by 1,655
Self-citationStaessen, J. A. (1999) · JAMA · doi:10.1001/jama.282.6.539 · Cited by 1,592
Prognostic Value of Ambulatory Blood-Pressure Recordings in Patients with Treated Hypertension
Clement, D. L., De Buyzere, M. L., De Bacquer, D. A., de Leeuw, P. W., Duprez, D. A., Fagard, R. H., Gheeraert, P. J., Missault, L. H., Braun, J. J., Six, R. O., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa022273 · Cited by 1,085
Bobrie, G. (2004) · JAMA · doi:10.1001/jama.291.11.1342 · Cited by 842
Staessen, J. A. (2004) · JAMA · doi:10.1001/jama.291.8.955 · Cited by 288
Mancia, G., & Parati, G. (2004) · Journal of Hypertension · doi:10.1097/00004872-200403000-00001 · Cited by 219
Home Blood Pressure Measurement
Verberk, W. J., Kroon, A. A., Kessels, A. G. H., & de Leeuw, P. W. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.05.058 · Cited by 212
Home Self Blood Pressure Measurement in General Practice The SMART Study
Chatellier, G. (1996) · American Journal of Hypertension · doi:10.1016/0895-7061(96)00018-0 · Cited by 116
Mengden, T., Binswanger, B., Spühler, T., Weisser, B., & Vetter, W. (1993) · Journal of Hypertension · doi:10.1097/00004872-199312000-00013 · Cited by 95
BOBRIE, G., DELONCA, J., MOULIN, C., GIACOMINO, A., POSTELVINAY, N., & ASMAR, R. (2005) · American Journal of Hypertension · doi:10.1016/j.amjhyper.2005.06.009 · Cited by 42
NIIRANEN, T., KANTOLA, I., VESALAINEN, R., JOHANSSON, J., & RUUSKA, M. (2006) · American Journal of Hypertension · doi:10.1016/j.amjhyper.2005.10.017 · Cited by 42
Telemonitoring of blood pressure self measurement in the OLMETEL study
Mengden, T., Ewald, S., Kaufmann, S., vor dem Esche, J., Uen, S., & Vetter, H. (2004) · Blood Pressure Monitoring · doi:10.1097/00126097-200412000-00010 · Cited by 39
Stergiou, G., Efstathiou, S., Skeva, II, Baibas, N., Kalkana, C., & Mountokalakis, T. (2002) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1001477 · Cited by 29
Cited by
Agarwal, R., Bills, J. E., Hecht, T. J. W., & Light, R. P. (2011) · Hypertension · doi:10.1161/hypertensionaha.110.160911 · Cited by 430
Bosworth, H. B. (2011) · Archives of Internal Medicine · doi:10.1001/archinternmed.2011.276 · Cited by 253
Measuring Blood Pressure for Decision Making and Quality Reporting: Where and How Many Measures?
Powers, B. J., Olsen, M. K., Smith, V. A., Woolson, R. F., Bosworth, H. B., & Oddone, E. Z. (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-154-12-201106210-00005 · Cited by 186
Home Blood Pressure Monitoring in the Diagnosis and Treatment of Hypertension: A Systematic Review
Stergiou, G. S., & Bliziotis, I. A. (2011) · American Journal of Hypertension · doi:10.1038/ajh.2010.194 · Cited by 182
Niiranen, T. J., Asayama, K., Thijs, L., Johansson, J. K., Ohkubo, T., Kikuya, M., Boggia, J., Hozawa, A., Sandoya, E., Stergiou, G. S., et al. (2013) · Hypertension · doi:10.1161/hypertensionaha.111.00100 · Cited by 120
Metadata
- Authors
- Ishikawa, J., Carroll, D. J., Kuruvilla, S., Schwartz, J. E., & Pickering, T. G.
- Venue
- Hypertension
- Published
- 2008-11
- Volume
- 52
- Issue
- 5
- Pages
- 856-864
- ISSN
- 0194-911X (ISSN-L)
- 1524-4563
- OpenAlex
- W2170707021
- Cited by
- 50
- References
- 15
- FWCI
- 3.30
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.