Ultrasound Assessment of Flow-Mediated Dilation
Open accessThe DOI matches its Crossref record; 65 of the 65 references it cites were found in a registry or an index.
Abstract
Developed in 1992, the flow-mediated dilation test is now the most commonly used noninvasive assessment of vascular endothelial function in humans. Since its inception, scientists have refined their understanding of the physiology, analysis, and interpretation of this measurement. Recently, a significant growth of knowledge has added to our understanding and implementation of this clinically relevant research methodology. Therefore, this tutorial provides timely insight into recent advances and practical information related to the ultrasonic assessment of vascular endothelial function in humans.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Atherosclerosis--an inflammatory disease
Ross, R. (1999) · New England Journal of Medicine · doi:10.1056/nejm199901143400207 · Cited by 21,725
Furchgott, R. F., & Zawadzki, J. V. (1980) · Nature · doi:10.1038/288373a0 · Cited by 12,064
Non-invasive detection of endothelial dysfunction in children and adults at risk of atherosclerosis
Celermajer, D. S., Sorensen, K. E., Gooch, V. M., Spiegelhalter, D. J., Miller, O. I., Sullivan, I. D., Lloyd, J. K., & Deanfield, J. E. (1992) · The Lancet · doi:10.1016/0140-6736(92)93147-f · Cited by 4,742 · cited 2×
“This same concept has an impact on the calculation of shear rate, which is derived from the Poiseuilles law, dependent on Doppler sample volume size and placement: (1) large, centered sample volume: 8 mean blood velocity/internal diameter; or (2) small, centered sample volume: 4 mean blood velocity/internal diameter.”
BackgroundMethodCorretti, M. C., Anderson, T. J., Benjamin, E. J., Celermajer, D., Charbonneau, F., Creager, M. A., Deanfield, J., Drexler, H., Gerhard-Herman, M., Herrington, D., et al. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01746-6 · Cited by 4,604
The Protective Effects of Estrogen on the Cardiovascular System
Mendelsohn, M. E., & Karas, R. H. (1999) · New England Journal of Medicine · doi:10.1056/nejm199906103402306 · Cited by 3,103
Close Relation of Endothelial Function in the Human Coronary and Peripheral Circulations
Anderson, T. J., Uehata, A., Gerhard, M. D., Meredith, I. T., Knab, S., Delagrange, D., Lieberman, E. H., Ganz, P., Creager, M. A., Yeung, A. C., et al. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)00327-4 · Cited by 2,033 · cited 2×
“(3) FMD(%) peak diameter baseline diameter”
BackgroundRegulatory Functions of the Vascular Endothelium
Epstein, F. H., Vane, J. R., Änggård, E. E., & Botting, R. M. (1990) · New England Journal of Medicine · doi:10.1056/nejm199007053230106 · Cited by 1,889
Celermajer, D. S., Sorensen, K. E., Georgakopoulos, D., Bull, C., Thomas, O., Robinson, J., & Deanfield, J. E. (1993) · Circulation · doi:10.1161/01.cir.88.5.2149 · Cited by 1,533
Effect of a single high-fat meal on endothelial function in healthy subjects
Vogel, R. A., Corretti, M. C., & Plotnick, G. D. (1997) · The American Journal of Cardiology · doi:10.1016/s0002-9149(96)00760-6 · Cited by 798
Measurement of blood flow by ultrasound: Accuracy and sources of error
Gill, R. W. (1985) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(85)90035-3 · Cited by 765
Cited by
Assessment of flow-mediated dilation in humans: a methodological and physiological guideline
Thijssen, D. H. J., Black, M. A., Pyke, K. E., Padilla, J., Atkinson, G., Harris, R. A., Parker, B., Widlansky, M. E., Tschakovsky, M. E., & Green, D. J. (2011) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00471.2010 · Cited by 1,483
Self-citationThe Assessment of Endothelial Function: From Research Into Clinical Practice
Flammer, A. J., Anderson, T., Celermajer, D. S., Creager, M. A., Deanfield, J., Ganz, P., Hamburg, N. M., Lüscher, T. F., Shechter, M., Taddei, S., et al. (2012) · Circulation · doi:10.1161/circulationaha.112.093245 · Cited by 1,153
Thijssen, D. H. J., Bruno, R. M., van Mil, A. C. C. M., Holder, S. M., Faita, F., Greyling, A., Zock, P. L., Taddei, S., Deanfield, J. E., Luscher, T., et al. (2019) · European Heart Journal · doi:10.1093/eurheartj/ehz350 · Cited by 995
Aging and vascular endothelial function in humans
Seals, D. R., Jablonski, K. L., & Donato, A. J. (2011) · Clinical Science · doi:10.1042/cs20100476 · Cited by 725
Rossman, M. J., Santos-Parker, J. R., Steward, C. A. C., Bispham, N. Z., Cuevas, L. M., Rosenberg, H. L., Woodward, K. A., Chonchol, M., Gioscia-Ryan, R. A., Murphy, M. P., et al. (2018) · Hypertension · doi:10.1161/hypertensionaha.117.10787 · Cited by 456
Alexander, Y., Osto, E., Schmidt-Trucksäss, A., Shechter, M., Trifunovic, D., Duncker, D. J., Aboyans, V., Bäck, M., Badimon, L., Cosentino, F., et al. (2021) · Cardiovascular Research · doi:10.1093/cvr/cvaa085 · Cited by 395
Marik, P. E., Levitov, A., Young, A., & Andrews, L. (2013) · Chest · doi:10.1378/chest.12-1274 · Cited by 243
Santos-Parker, J. R., Strahler, T. R., Bassett, C. J., Bispham, N. Z., Chonchol, M. B., & Seals, D. R. (2017) · Aging · doi:10.18632/aging.101149 · Cited by 210
Pierce, G. L., Eskurza, I., Walker, A. E., Fay, T. N., & Seals, D. R. (2011) · Clinical Science · doi:10.1042/cs20100174 · Cited by 209
Barona, J., Aristizabal, J. C., Blesso, C. N., Volek, J. S., & Fernandez, M. L. (2012) · The Journal of Nutrition · doi:10.3945/jn.112.162743 · Cited by 173
Chronic resveratrol consumption improves brachial flow-mediated dilatation in healthy obese adults
Wong, R. H. X., Berry, N. M., Coates, A. M., Buckley, J. D., Bryan, J., Kunz, I., & Howe, P. R. C. (2013) · Journal of Hypertension · doi:10.1097/hjh.0b013e328362b9d6 · Cited by 162
“Flow-mediated dilatation FMD was assessed in the brachial artery using twodimensional B-mode ultrasound with a 12MHz transducer (General Electric Logiq 5 Expert) in accordance with published guidelines [15].”
MethodHarris, R. A., Pedersen-White, J., Guo, D.-H., Stallmann-Jorgensen, I. S., Keeton, D., Huang, Y., Shah, Y., Zhu, H., & Dong, Y. (2011) · American Journal of Hypertension · doi:10.1038/ajh.2011.12 · Cited by 159
Self-citationRifai, L., Pisano, C., Hayden, J., Sulo, S., & Silver, M. A. (2015) · Baylor University Medical Center Proceedings · doi:10.1080/08998280.2015.11929216 · Cited by 82
Soares, A. H., Horie, N. C., Chiang, L. A. P., Caramelli, B., Matheus, M. G., Campos, A. H., Marti, L. C., Rocha, F. A., Mancini, M. C., Costa, E. M. F., et al. (2018) · International Journal of Obesity · doi:10.1038/s41366-018-0105-2 · Cited by 63
Vascular Dysfunction, Oxidative Stress, and Inflammation in Chronic Kidney Disease
Nowak, K. L., Jovanovich, A., Farmer-Bailey, H., Bispham, N., Struemph, T., Malaczewski, M., Wang, W., & Chonchol, M. (2020) · Kidney360 · doi:10.34067/kid.0000962019 · Cited by 30
“All measurements were made under supine, overnight fasted (water only) conditions, following standard recommendations including 24-hr abstention from physical activity, and in a climate-controlled room.(19) Participants refrained from non-prescription medications for 48-hours prior to testing, but prescription medicat…”
MethodGrafe, K., Bendick, P., Burr, M., Boura, J., & Franklin, B. A. (2018) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2018.1519385 · Cited by 16
Metadata
- Authors
- Harris, R. A., Nishiyama, S. K., Wray, D. W., & Richardson, R. S.
- Venue
- Hypertension
- Published
- 2010-05
- Volume
- 55
- Issue
- 5
- Pages
- 1075-1085
- ISSN
- 0194-911X (ISSN-L)
- 1524-4563
- OpenAlex
- W2136329682
- Cited by
- 667
- References
- 65
- FWCI
- 22.69
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.