Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 167

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Lack of Specificity of Commercial Antibodies Leads to Misidentification of Angiotensin Type 1 Receptor Protein

Open access
Herrera, Marcela, Sparks, Matthew A., Alfonso-Pecchio, Adolfo R., Harrison-Bernard, Lisa M., Coffman, Thomas M. · 2013 · Hypertension

Abstract

The angiotensin II type 1 receptor (AT 1 R) mediates most hypertensive actions of angiotensin II. To understand the molecular regulation of the AT 1 R in normal physiology and pathophysiology, methods for sensitive and specific detection of AT 1 R protein are required. Here, we examined the specificity of a panel of putative AT 1 R antibodies that are commonly used by investigators in the field. For these studies, we carried out Western blotting and immunohistochemistry with kidney tissue from wild-type mice and genetically modified mice lacking the major murine AT 1 R isoform, AT 1A (AT 1A KO), or with combined deficiency of both the AT 1A and AT 1B isoforms (AT 1AB KO). For the 3 antibodies tested, Western blots of protein homogenates from wild-type kidneys yielded distinct bands with the expected size range for AT 1 R. In addition, these bands appeared identical in samples from mice lacking 1 or both murine AT 1 R isoforms. Additionally, the pattern of immunohistochemical staining in kidneys, liver, and adrenal glands of wild-type mice was very similar to that of AT 1AB KO mice completely lacking all AT 1 R. We verified the absence of AT 1 R subtypes in each mouse line by the following: (1) quantitative polymerase chain reaction documenting the absence of mRNA species, and (2) functionally by assessing angiotensin II–dependent vasoconstriction, which was substantially blunted in both AT 1A KOs and AT 1AB KOs. Finally, these antibodies failed to detect epitope-tagged AT 1A R protein overexpressed in human embryonic kidney cells. We conclude that anti-AT 1 R antibodies available from commercial sources and commonly used in published studies exhibit nonspecific binding in mouse tissue that may lead to erroneous results.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/hypertensionaha.112.203679

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 167

Metadata

Authors
Herrera, M., Sparks, M. A., Alfonso-Pecchio, A. R., Harrison-Bernard, L. M., & Coffman, T. M.
Venue
Hypertension
Published
2013-01
Volume
61
Issue
1
Pages
253-258
ISSN
  • 0194-911X (ISSN-L)
  • 1524-4563
OpenAlex
W2152701586
Cited by
167
References
3
FWCI
8.82
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Lack of Specificity of Commercial Antibodies Leads to Misidentification of Angiotensin Type 1 Receptor Protein. https://app.cochat.ai/papers/10.1161/hypertensionaha.112.203679
The paper
Herrera, M., Sparks, M. A., Alfonso-Pecchio, A. R., Harrison-Bernard, L. M., & Coffman, T. M. (2013). Lack of Specificity of Commercial Antibodies Leads to Misidentification of Angiotensin Type 1 Receptor Protein. Hypertension. https://doi.org/10.1161/hypertensionaha.112.203679

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.