Impact of Atrial Fibrillation on the Accuracy of Oscillometric Blood Pressure Monitoring
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
The introduction of automated oscillometric blood pressure monitors was the basis for today’s widespread use of blood pressure self-measurement. However, in atrial fibrillation, there is a controversial debate on the use of oscillometry because there is a high variability of heart rate and stroke volume. To date, the accuracy of oscillometric blood pressure monitoring in atrial fibrillation has only been investigated using auscultatory sphygmomanometry as reference method, which may be biased by arrhythmia as well. We performed a cross-sectional study in 102 patients (52 sinus rhythm, 50 atrial fibrillation) assessing the accuracy of an automated and validated oscillometric upper arm (M5 Professional, Omron) and wrist device (R5 Professional, Omron) to invasively assessed arterial pressure. Blood pressure values were calculated as the mean of 3 consecutive measurements. Systolic and diastolic blood pressure did not significantly differ in patients with sinus rhythm and atrial fibrillation, independent of the method of measurement ( P >0.05 each). The within-subject variability of the oscillometric measurements was higher in patients with atrial fibrillation compared with sinus rhythm ( P <0.01 each). The biases of systolic and diastolic blood pressure, however, did not significantly differ in presence or absence of atrial fibrillation in Bland-Altmann analysis ( P >0.05 each). In conclusion, atrial fibrillation did not significantly affect the accuracy of oscillometric measurements, if 3 repeated measurements were performed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Go, A. S., Hylek, E. M., Phillips, K. A., Chang, Y., Henault, L. E., Selby, J. V., & Singer, D. E. (2001) · JAMA · doi:10.1001/jama.285.18.2370 · Cited by 6,205
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Circulation · doi:10.1161/01.cir.0000154900.76284.f6 · Cited by 3,985
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Hypertension · doi:10.1161/01.hyp.0000150859.47929.8e · Cited by 2,051
Bobrie, G. (2004) · JAMA · doi:10.1001/jama.291.11.1342 · Cited by 842 · cited 1×
“Blood pressure self-measurement, today almost exclusively performed by oscillometric devices, is a better predictor of cardiovascular events than office blood pressure.(19) Moreover, home blood pressure monitoring improves both therapeutic compliance and blood pressure control.”
BackgroundParati, G., Stergiou, G. S., Asmar, R., Bilo, G., de Leeuw, P., Imai, Y., Kario, K., Lurbe, E., Manolis, A., Mengden, T., et al. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e328308da66 · Cited by 837
Automated blood pressure measurement in atrial fibrillation: a systematic review and meta-analysis
Stergiou, G. S., Kollias, A., Destounis, A., & Tzamouranis, D. (2012) · Journal of Hypertension · doi:10.1097/hjh.0b013e32835850d7 · Cited by 120
Comparing compliance patterns between randomized treatments
Vrijens, B., & Goetghebeur, E. (1997) · Controlled Clinical Trials · doi:10.1016/s0197-2456(96)00235-8 · Cited by 114 · cited 3×
“The M5 (identical to the M6 HEM-7001-E) has been validated according to European Society of Hypertension and British Hypertension Society protocol and was used according to manufacturer instructions.11,12 Moreover, the M5 underwent validation procedures for elderly and for obese patients.13,14 The R5 was validated by…”
BackgroundMethodInfluential
Cited by
The Japanese Society of Hypertension Guidelines for the Management of Hypertension (JSH 2019)
Umemura, S., Arima, H., Arima, S., Asayama, K., Dohi, Y., Hirooka, Y., Horio, T., Hoshide, S., Ikeda, S., Ishimitsu, T., et al. (2019) · Hypertension Research · doi:10.1038/s41440-019-0284-9 · Cited by 1,880
Blood Pressure Assessment in Adults in Clinical Practice and Clinic-Based Research
Muntner, P., Einhorn, P. T., Cushman, W. C., Whelton, P. K., Bello, N. A., Drawz, P. E., Green, B. B., Jones, D. W., Juraschek, S. P., Margolis, K. L., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.10.069 · Cited by 199
“However, BP may be reasonably accurate in patients with AF if 3 or more readings are obtained (102).”
BackgroundOscillometric Blood Pressure Estimation: Past, Present, and Future
Forouzanfar, M., Dajani, H. R., Groza, V. Z., Bolic, M., Rajan, S., & Batkin, I. (2015) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2015.2434215 · Cited by 196
Stergiou, G. S., Kyriakoulis, K. G., Stambolliu, E., Destounis, A., Karpettas, N., Kalogeropoulos, P., & Kollias, A. (2019) · Journal of Hypertension · doi:10.1097/hjh.0000000000002201 · Cited by 67
“Fourteen articles including 12 noninvasive validation studies (781 patients; 5 home, 2 ambulatory, 4 office devices) [25–35] and four invasive ones (179 patients; 2 office, 2 home devices) [16,36,37] were eligible and included in the meta-analysis.”
BackgroundArmstrong, M. K., Schultz, M. G., Picone, D. S., Black, J. A., Dwyer, N., Roberts-Thomson, P., & Sharman, J. E. (2019) · Hypertension · doi:10.1161/hypertensionaha.119.12674 · Cited by 59
Metadata
- Authors
- Pagonas, N., Schmidt, S., Eysel, J., Compton, F., Hoffmann, C., Seibert, F., Hilpert, J., Tschöpe, C., Zidek, W., & Westhoff, T. H.
- Venue
- Hypertension
- Published
- 2013-09
- Volume
- 62
- Issue
- 3
- Pages
- 579-584
- ISSN
- 0194-911X (ISSN-L)
- 1524-4563
- OpenAlex
- W2109749844
- Cited by
- 81
- References
- 7
- FWCI
- 3.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Impact of Atrial Fibrillation on the Accuracy of Oscillometric Blood Pressure Monitoring. https://app.cochat.ai/papers/10.1161/hypertensionaha.113.01426
- The paper
- Pagonas, N., Schmidt, S., Eysel, J., Compton, F., Hoffmann, C., Seibert, F., Hilpert, J., Tschöpe, C., Zidek, W., & Westhoff, T. H. (2013). Impact of Atrial Fibrillation on the Accuracy of Oscillometric Blood Pressure Monitoring. Hypertension. https://doi.org/10.1161/hypertensionaha.113.01426
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.