CoChat

Aortic Stiffness, Increased White Matter Free Water, and Altered Microstructural Integrity: A Continuum of Injury

Open access
Maillard, Pauline, Mitchell, Gary F., Himali, Jayandra J., Beiser, Alexa, Fletcher, Evan, Tsao, Connie W., Pase, Matthew P., Satizabal, Claudia L., Vasan, Ramachandran S., Seshadri, Sudha, DeCarli, Charles · 2017 · Stroke
Cited by 136

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

Background and Purpose—: Previous reports from the Framingham Heart Study have identified cross-sectional associations of arterial stiffness, as reflected by carotid–femoral pulse wave velocity (CFPWV) and systolic blood pressure with vascular brain injury. The purpose of this study is to examine free water (FW), fractional anisotropy (FA), and white matter hyperintensities (WMH) in relation to arterial stiffness among subjects of the Framingham Offspring and Third-Generation cohorts. Methods—: In 2422 participants aged 51.3±11.6 years, FA, FW, and WMH were related to CFPWV using voxel-based linear and generalized linear regressions, adjusting for relevant covariables. Mean FW, mean FA, and WMH burden (log transformed) were computed within white matter (WM) region and related to systolic blood pressure and CFPWV using multiple mediation analyses. Results—: CFPWV was found to be associated with higher FW, lower FA, and higher WMH incidence in WM areas covering, respectively, 356.1, 211.8, and 10.9 mL of the WM mask. Mediation analyses revealed that the effect of systolic blood pressure on FW was mediated by CFPWV (direct and indirect effects: a=0.040; P <0.001, and a′=0.020; P >0.05). Moreover, the effect of CFPWV on FA was mediated by FW (direct and indirect effects: b=−0.092; P <0.001, and b′=0.012; P >0.05), whose effect on WMH was, in turn, mediated by FA (direct and indirect effects: c=0.246; P <0.001, and c′=0.116; P >0.05). Conclusions—: From these data, we propose a biomechanical hypothesis designed for future research experiments to explain how hemodynamic alteration may lead to WM injury by impacting cerebral water content and more subtly WM integrity, to finally lead to WMH development.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/strokeaha.116.016321

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

Metadata

Authors
Maillard, P., Mitchell, G. F., Himali, J. J., Beiser, A., Fletcher, E., Tsao, C. W., Pase, M. P., Satizabal, C. L., Vasan, R. S., Seshadri, S., & DeCarli, C.
Venue
Stroke
Published
2017-06
Volume
48
Issue
6
Pages
1567-1573
ISSN
  • 0039-2499 (ISSN-L)
  • 1524-4628
OpenAlex
W2610653416
Cited by
136
References
11
FWCI
6.34
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.