CoChat

The effective reduction of tourniquet application time after minor modification of the CLSI H03-A6 blood collection procedure

Open access
Lima-Oliveira, Gabriel, Lippi, Giuseppe, Salvagno, Gian Luca, Montagnana, Martina, Picheth, Geraldo, Guidi, Gian Cesare · 2013 · Biochemia Medica
Cited by 40

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

INTRODUCTION: The phlebotomists' procedures are a still source of laboratory variability. The aim of this study was to verify the efficacy of minor modification in procedure for collection of diagnostic blood specimens by venipuncture from CLSI H03-A6 document is able to reduce the tourniquet application time. MATERIALS AND METHODS: Thirty phlebotomists were invited to participate. Each phlebotomist was trained individually to perform the new venipuncture procedure that shortens the time of tourniquet release and removal. The phlebotomy training program was delivered over 8h. After training, all phlebotomists were monitored for 20 working days, to guarantee the adoption of the correct new procedures for collection of diagnostic blood specimens. After this time frame the phlebotomists were evaluated to verify whether the new procedure for blood collection derived from CLSI H03-A6 document was effective to improve the quality process by decrease in tourniquet application time. We compared the tourniquet application time and qualitative difference of phlebotomy procedures between laboratories before and after phlebotomy training. RESULTS: The overall mean +/- SD tourniquet application time before and afterthis intervention were 118 +/- 1 s and 30 +/- 1 s respectively. Minor modifications in procedure for blood collection were able to reduce significantly the tourniquet application time (-88 s, P < 0.001). CONCLUSIONS: The minor modifications in procedure for collection of diagnostic blood specimens by venipuncture from CLSI H03-A6 document were able to reduce the tourniquet application time. Now the proposed new procedure for collection of diagnostic blood specimens by venipuncture could be considered usefulness and should be put into practice by all quality laboratory managers and/or phlebotomy coordinators to avoid preanalytical errors regard venous stasis and guarantee patient safety.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.11613/bm.2013.037

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

Metadata

Authors
Lima-Oliveira, G., Lippi, G., Salvagno, G. L., Montagnana, M., Picheth, G., & Guidi, G. C.
Venue
Biochemia Medica
Published
2013
Volume
23
Issue
3
Pages
308-315
ISSN
  • 1330-0962 (ISSN-L)
  • 1846-7482
OpenAlex
W2168552869
Cited by
40
References
6
FWCI
3.06
Type
journal article
Language
en
Open access
diamond

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.