CoChat

Vein Pattern Locating Technology for Cannulation: A Review of the Low-Cost Vein Finder Prototypes Utilizing near Infrared (NIR) Light to Improve Peripheral Subcutaneous Vein Selection for Phlebotomy

Open access

The DOI matches its Crossref record; 67 of the 67 references it cites were found in a registry or an index.

Abstract

One of the most common means for diagnosis is through medical laboratory testing, which primarily uses venous blood as a sample. This requires an invasive method by cannulation that needs proper vein selection. The use of a vein finder would help the phlebotomist to easily locate the vein, preventing possible pre-analytical error in the specimen collection and even more discomfort and pain to the patient. This paper is a review of the scientific publications on the different developed low-cost vein finder prototypes utilizing camera assisted near infrared (NIR) light technology. Methods: Electronic databases were searched online, these included PubMed (PMC), MEDLINE, Science Direct, ResearchGate, and Institute of Electrical and Electronics Engineers (IEEE) Xplore digital library. Specifically, publications with the terms vein finder prototype, NIR technology, vein detection, and infrared imaging were screened. In addition, reference lists were used to further review related publications. Results: Cannulation challenges medical practitioners because of the different factors that can be reduced by the utilization of a vein finder. A limited number of publications regarding the assessment of personnel performing cannulation were observed. Moreover, variations in methodology, number of patients, type of patients according to their demographics and materials used in the assessment of the developed prototypes were noted. Some studies were limited with regard to the actual human testing of the prototype. Conclusions: The development of a low-cost effective near infrared (NIR) vein finder remains in the phase of improvement. Since, it is being challenged by different human factors, increasing the number of parameters and participants/human for actual testing of the prototypes must also be taken into consideration for possible commercialization. Finally, it was noted that publications regarding the assessment of the performance of phlebotomists using vein finders were limited.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/s19163573

Cites

67 of 67 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Research strategy on digital library databases.
Figure 1 Research strategy on digital library databases.CC BY · PubMed Central
Figure 2 Basic components of a near infrared (NIR) vein finder prototype: (a) Reflected light type, and (b) transillumination type.
Figure 2 Basic components of a near infrared (NIR) vein finder prototype: (a) Reflected light type, and (b) transillumination type.CC BY · PubMed Central
Figure 3 Sample projected vein image of the dorsal hand using NIR vein finder prototype.
Figure 3 Sample projected vein image of the dorsal hand using NIR vein finder prototype.CC BY · PubMed Central
Figure 4 Sample veins image from different wavelengths: (a) 850 nm [50] and (b) 696 nm [43].
Figure 4 Sample veins image from different wavelengths: (a) 850 nm [50] and (b) 696 nm [43].CC BY · PubMed Central
Figure 5 The antecubital fossa with the veins for venipuncture.
Figure 5 The antecubital fossa with the veins for venipuncture.CC BY · PubMed Central
Figure 6 (a) Selecting a point from fused images to extract values of: (b) Depth and (c) thickness using the proposed imaging system [71].
Figure 6 (a) Selecting a point from fused images to extract values of: (b) Depth and (c) thickness using the proposed imaging system [71].CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

2 more claims about this paper

Create a free account to see every claim other papers make about this one.

See all claims — free account

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 67 references

Research works printed but not linked: 2

  1. Doshi, 2013, Non-invasive optical sensor for hemoglobin determination, Int. J. Eng. Res. Appl. (Ijera), 3, 559
  2. Crisan, S., Tarnovan, I., and Crisan, T. (2007, January 19–21). Vein Pattern Recognition. Image Enhancement and feature Extraction Algorithms. Proceedings of the 15th IMEKO TC4 Symposium on Novelties in Electrical Measurements and Instrumentation, Iaşi, Romania.

Cited by

See all 93

Metadata

Authors
Pan, C.-T., Francisco, M. D., Yen, C.-K., Wang, S.-Y., & Shiue, Y.-L.
Affiliations
  • National Sun Yat-sen University (TW)
  • Department of Mechanical and Electro-Mechanical Engineering, National Sun Yat-sen University (NSYSU), Kaohsiung 80424, Taiwan
Corresponding author
Shiue, Yow-Ling
Venue
Sensors
Publisher
MDPI AG
Published
2019-08-16
Volume
19
Issue
16
Pages
3573
ISSN
1424-8220 (ISSN-L)
OpenAlex
W2967660745
Cited by
93
References
67
Citations by year
2026: 10 · 2025: 15 · 2024: 11 · 2023: 16 · 2022: 12 · 2021: 17 · 2020: 12
FWCI
1.54
Type
journal article
Language
en
Open access
Locations
  • Sensors (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
National Science Council
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Infrared Thermography in Medicine
  • Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Central Venous Catheters and Hemodialysis
Keywords
near-infrared imaging, cannulation, phlebotomy, low-cost prototype, vein detection, pre-analytical errors, blood sampling, human factors
MeSH terms
Catheterization, Cost-Benefit Analysis, Humans, Semiconductors, Veins, Phlebotomy, Spectroscopy, Near-Infrared

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Vein Pattern Locating Technology for Cannulation: A Review of the Low-Cost Vein Finder Prototypes Utilizing near Infrared (NIR) Light to Improve Peripheral Subcutaneous Vein Selection for Phlebotomy. https://app.cochat.ai/papers/10.3390/s19163573
The paper
Pan, C.-T., Francisco, M. D., Yen, C.-K., Wang, S.-Y., & Shiue, Y.-L. (2019). Vein Pattern Locating Technology for Cannulation: A Review of the Low-Cost Vein Finder Prototypes Utilizing near Infrared (NIR) Light to Improve Peripheral Subcutaneous Vein Selection for Phlebotomy. Sensors. https://doi.org/10.3390/s19163573

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.