The effective reduction of tourniquet application time after minor modification of the CLSI H03-A6 blood collection procedure
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
INTRODUCTION: The phlebotomists' procedures are a still source of laboratory variability. The aim of this study was to verify the efficacy of minor modification in procedure for collection of diagnostic blood specimens by venipuncture from CLSI H03-A6 document is able to reduce the tourniquet application time. MATERIALS AND METHODS: Thirty phlebotomists were invited to participate. Each phlebotomist was trained individually to perform the new venipuncture procedure that shortens the time of tourniquet release and removal. The phlebotomy training program was delivered over 8h. After training, all phlebotomists were monitored for 20 working days, to guarantee the adoption of the correct new procedures for collection of diagnostic blood specimens. After this time frame the phlebotomists were evaluated to verify whether the new procedure for blood collection derived from CLSI H03-A6 document was effective to improve the quality process by decrease in tourniquet application time. We compared the tourniquet application time and qualitative difference of phlebotomy procedures between laboratories before and after phlebotomy training. RESULTS: The overall mean +/- SD tourniquet application time before and afterthis intervention were 118 +/- 1 s and 30 +/- 1 s respectively. Minor modifications in procedure for blood collection were able to reduce significantly the tourniquet application time (-88 s, P < 0.001). CONCLUSIONS: The minor modifications in procedure for collection of diagnostic blood specimens by venipuncture from CLSI H03-A6 document were able to reduce the tourniquet application time. Now the proposed new procedure for collection of diagnostic blood specimens by venipuncture could be considered usefulness and should be put into practice by all quality laboratory managers and/or phlebotomy coordinators to avoid preanalytical errors regard venous stasis and guarantee patient safety.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Influence of short-term venous stasis on clinical chemistry testing
Lippi, G., Salvagno, G. L., Montagnana, M., Brocco, G., & Guidi, G. C. (2005) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2005.146 · Cited by 81
Self-citationShort-term venous stasis influences routine coagulation testing
Lippi, G., Salvagno, G. L., Montagnana, M., & Guidi, G. C. (2005) · Blood Coagulation & Fibrinolysis · doi:10.1097/01.mbc.0000178828.59866.03 · Cited by 66
Self-citationLima-Oliveira, G., Lippi, G., Salvagno, G. L., Montagnana, M., Picheth, G., & Guidi, G. C. (2012) · Biochemia Medica · doi:10.11613/bm.2012.036 · Cited by 66 · cited 10×
“We decided to retrain and re-evaluate the thirty phlebotomists twice after the first assessment (2,4), in order to minimize the inter-individual variability of performance since we were aware of the relevance of the workday routine of these professionals.”
BackgroundMethodResultSelf-citationLIMA‐OLIVEIRA, G., LIPPI, G., SALVAGNO, G. L., MONTAGNANA, M., SCARTEZINI, M., GUIDI, G. C., & PICHETH, G. (2011) · International Journal of Laboratory Hematology · doi:10.1111/j.1751-553x.2011.01305.x · Cited by 46
Self-citationElimination of the venous stasis error for routine coagulation testing by transillumination
Lima-Oliveira, G., Salvagno, G. L., Lippi, G., Montagnana, M., Scartezini, M., Picheth, G., & Guidi, G. C. (2011) · Clinica Chimica Acta · doi:10.1016/j.cca.2011.04.008 · Cited by 38 · cited 1×
“This significant reduction of the application time is able to eliminate the venous stasis impact, that is an important source of unpredictable laboratory variability (5-8,12-14).”
BackgroundSelf-citationTo mix or not to mix venous blood samples collected in vacuum tubes?
Parenmark, A., & Landberg, E. (2011) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2011.705 · Cited by 33 · cited 3×
“, all blood specimens collected in vacuum tube systems by venipuncture apparently do not need to be mixed (9).”
BackgroundMethod
Cited by
Standardization of collection requirements for fasting samples
Simundic, A. M., Cornes, M., Grankvist, K., Lippi, G., & Nybo, M. (2014) · Clinica Chimica Acta · doi:10.1016/j.cca.2013.11.008 · Cited by 156
Self-citationLima-Oliveira, G., Volanski, W., Lippi, G., Picheth, G., & Guidi, G. C. (2017) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2017.1295317 · Cited by 117
Self-citationLima-Oliveira, G., Lippi, G., Salvagno, G. L., Picheth, G., & Guidi, G. C. (2015) · Journal of Medical Biochemistry · doi:10.2478/jomb-2014-0043 · Cited by 102
Self-citationPan, C.-T., Francisco, M. D., Yen, C.-K., Wang, S.-Y., & Shiue, Y.-L. (2019) · Sensors · doi:10.3390/s19163573 · Cited by 93
“The procedure for venipuncture cannot be considered as a gold standard yet, since errors are still being detected [20] with continuous recommendations for improvements were supplemented.”
BackgroundResultPatient identification and tube labelling – a call for harmonisation
van Dongen-Lases, E. C., Cornes, M. P., Grankvist, K., Ibarz, M., Kristensen, G. B. B., Lippi, G., Nybo, M., Simundic, A.-M., & on behalf of the Working Group for Preanalytical Phase (WG-P (2016) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2015-1089 · Cited by 69
Self-citation
Metadata
- Authors
- Lima-Oliveira, G., Lippi, G., Salvagno, G. L., Montagnana, M., Picheth, G., & Guidi, G. C.
- Venue
- Biochemia Medica
- Published
- 2013
- Volume
- 23
- Issue
- 3
- Pages
- 308-315
- ISSN
- 1330-0962 (ISSN-L)
- 1846-7482
- OpenAlex
- W2168552869
- Cited by
- 40
- References
- 6
- FWCI
- 3.06
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.