In Vivo Respiratory-Gated Micro-CT Imaging in Small-Animal Oncology Models
Open accessThe DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
Micro-computed tomography (micro-CT) is becoming an accepted research tool for the noninvasive examination of laboratory animals such as mice and rats, but to date, in vivo scanning has largely been limited to the evaluation of skeletal tissues. We use a commercially available micro-CT device to perform respiratory gated in vivo acquisitions suitable for thoracic imaging. The instrument is described, along with the scan protocol and animal preparation techniques. Preliminary results confirm that lung tumors as small as 1 mm in diameter are visible in vivo with these methods. Radiation dose was evaluated using several approaches, and was found to be approximately 0.15 Gy for this respiratory-gated micro-CT imaging protocol. The combination of high-resolution CT imaging and respiratory-gated acquisitions appears well-suited to serial in vivo scanning.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Feldkamp, L. A., Davis, L. C., & Kress, J. W. (1984) · Journal of the Optical Society of America A · doi:10.1364/josaa.1.000612 · Cited by 6,319 · cited 2×
“The detector is a charge coupled device with an active imaging area of 112 56 mm and an element size of 27 mm. Isotropic voxels are produced using a modified Feldkamp [18] reconstruction process and are 91 91 91 mm in the in vivo scan mode.”
MethodSomatic activation of the K-ras oncogene causes early onset lung cancer in mice
Johnson, L., Mercer, K., Greenbaum, D., Bronson, R. T., Crowley, D., Tuveson, D. A., & Jacks, T. (2001) · Nature · doi:10.1038/35074129 · Cited by 1,179 · cited 1×
“Tyler Jacks (Massachusetts Institute of Technology) developed a mouse model (129SV) carrying targeted mutations in the k-ras gene [19].”
BackgroundThe direct examination of three-dimensional bone architecture in vitro by computed tomography
Feldkamp, L. A., Goldstein, S. A., Parfitt, M. A., Jesion, G., & Kleerekoper, M. (1989) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650040103 · Cited by 1,071
High resolution X-ray computed tomography: an emerging tool for small animal cancer research
Paulus, M. J., Gleason, S. S., Kennel, S. J., Hunsicker, P. R., & Johnson, D. K. (2000) · Neoplasia · doi:10.1038/sj.neo.7900069 · Cited by 490
McDonald, S., Rubin, P., Phillips, T. L., & Marks, L. B. (1995) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(94)00429-o · Cited by 401
In vivo, three-dimensional microscopy of trabecular bone
Dr. Kinney, J. H., Lane, N. E., & Haupt, D. L. (1995) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650100213 · Cited by 230 · cited 1×
“[4] utilized micro-CT to examine trabecular bone architecture in a rat osteoporosis model in vivo.”
MethodBorah, B., Gross, G. J., Dufresne, T. E., Smith, T. S., Cockman, M. D., Chmielewski, P. A., Lundy, M. W., Hartke, J. R., & Sod, E. W. (2001) · The Anatomical Record · doi:10.1002/ar.1060 · Cited by 205
3D computed X-ray tomography of human cancellous bone at 8 μm spatial and 10−4 energy resolution
Bonse, U., Busch, F., Günnewig, O., Beckmann, F., Pahl, R., Delling, G., Hahn, M., & Graeff, W. (1994) · Bone and Mineral · doi:10.1016/s0169-6009(08)80205-x · Cited by 171 · cited 1×
“This study used a high-resolution CT instrument called an X-ray tomographic microscope, which demonstrated a limiting resolution of 8 mm [17].”
MethodDavid, V., Laroche, N., Boudignon, B. M., Lafage‐Proust, M., Alexandre, C., Ruegsegger, P., & Vico, L. (2003) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2003.18.9.1622 · Cited by 169 · cited 1×
“Another recently published in vivo conebeam micro-CT study monitored cancellous bone alterations in hindlimb-unloaded female rats [8].”
BackgroundThe use of microcomputed tomography to study microvasculature in small rodents
Bentley, M. D., Ortíz, M. C., Ritman, E. L., & Romero, J. C. (2002) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00560.2001 · Cited by 168
Paulus, M. J., Gleason, S. S., Easterly, M. E., & Foltz, C. J. (2001) · PubMed · Cited by 146
Schmidt, C., Priemel, M., Kohler, T., Weusten, A., Müller, R., Amling, M., & Eckstein, F. (2003) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2003.18.8.1486 · Cited by 109
Barbier, A., Martel, C., de Vernejoul, M. C., Tirode, F., Nys, M., Mocaer, G., Morieux, C., Murakami, H., & Lacheretz, F. (1999) · Journal of Bone and Mineral Metabolism · doi:10.1007/s007740050061 · Cited by 76
Yamashita, T., Nabeshima, Y., & Noda, M. (2000) · Journal of Endocrinology · doi:10.1677/joe.0.1640239 · Cited by 74
Hierarchical Structure of Bone and Micro-Computed Tomography
McCreadie, B. R., Goulet, R. W., Feldkamp, L. A., & Goldstein, S. A. (2001) · Advances in experimental medicine and biology · doi:10.1007/978-1-4615-0651-5_8 · Cited by 29
Miller, G. G., Dawson, D. T., & Battista, J. J. (1986) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(86)90134-3 · Cited by 23
Cited by
In vivo small-animal imaging using micro-CT and digital subtraction angiography
Badea, C. T., Drangova, M., Holdsworth, D. W., & Johnson, G. A. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/19/r01 · Cited by 264
Engineered nanoparticles for biomolecular imaging
Mahmoudi, M., Serpooshan, V., & Laurent, S. (2011) · Nanoscale · doi:10.1039/c1nr10326a · Cited by 262
Current Status of Developments and Applications of Micro-CT
Ritman, E. L. (2011) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071910-124717 · Cited by 243
Micro‐CT with respiratory and cardiac gating
Badea, C., Hedlund, L. W., & Johnson, G. A. (2004) · Medical Physics · doi:10.1118/1.1812604 · Cited by 196
In Vivo mouse imaging and spectroscopy in drug discovery
Beckmann, N., Kneuer, R., Gremlich, H., Karmouty‐Quintana, H., Blé, F., & Müller, M. (2007) · NMR in Biomedicine · doi:10.1002/nbm.1153 · Cited by 118
Metadata
- Authors
- Cavanaugh, D., Johnson, E., Price, R. E., Kurie, J., Travis, E. L., & Cody, D. D.
- Venue
- Molecular Imaging
- Publisher
- SAGE Publications
- Published
- 2004-01-01
- Volume
- 3
- Issue
- 1
- Pages
- 55-62
- ISSN
- 1535-3508 (ISSN-L)
- 1536-0121
- OpenAlex
- W2101587217
- Cited by
- 158
- References
- 16
- FWCI
- 8.82
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.