Power assist method based on Phase Sequence and muscle force condition for HAL
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
An exoskeleton robot can replace the wearer's motion function by operating the human's body. The purpose of this study is to propose a power assist method of walking, standing up and going up stairs based on autonomous motion of the exoskeleton robot suit, HAL (Hybrid assistive Limb), and verify the effectiveness of this method by experiment. In order to realize power assist of tasks (walking, standing up and going up stairs) autonomically, we used the Phase Sequence control which generates a task by transiting some simple basic motions called Phases. A task was divided into some Phases on the basis of the task performed by a normal person. The joint moving modes were categorized into active, passive and free modes according to the characteristic of the muscle force conditions. The autonomous motions which HAL generates in each Phase were designed corresponding to one of the categorized modes. The power assist experiments were performed by using the autonomous motion with a focus on the active mode. The experimental results showed that the wearer's muscle activation levels in each Phase were significantly reduced. With this, we confirmed the effectiveness of the proposed assist method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A myosignal-based powered exoskeleton system
Rosen, J., Brand, M., Fuchs, M. B., & Arcan, M. (2001) · IEEE Transactions on Systems, Man, and Cybernetics - Part A: Systems and Humans · doi:10.1109/3468.925661 · Cited by 437
Power assist method for HAL-3 using EMG-based feedback controller
Kawamoto, H., Lee, S., Kanbe, S., & Sankai, Y. (2004) · SMC'03 Conference Proceedings. 2003 IEEE International Conference on Systems, Man and Cybernetics. Conference Theme - System Security and Assurance (Cat. No.03CH37483) · doi:10.1109/icsmc.2003.1244649 · Cited by 392
Self-citationLee, S., & Sankai, Y. (2003) · IEEE/RSJ International Conference on Intelligent Robots and System · doi:10.1109/irds.2002.1043967 · Cited by 291
Self-citationKazerooni, H., & Guo, J. (1993) · Journal of Dynamic Systems Measurement and Control · doi:10.1115/1.2899068 · Cited by 119
Kasaoka, K., & Sankai, Y. (2002) · doi:10.1109/iros.2001.977204 · Cited by 104
Self-citationDynamics and Control of Robotic Systems Worn by Humans
Kazerooni, H., & Mahoney, S. L. (1991) · Journal of Dynamic Systems Measurement and Control · doi:10.1115/1.2896421 · Cited by 91
Design of a power assist system with consideration of actuator's maximum torque
HAYASHIBARA, Y., Tanie, K., & Arai, H. (2002) · IEEE International Workshop on Robot and Human Communication (RO-MAN) · doi:10.1109/roman.1995.531990 · Cited by 20
Cited by
State of the Art and Future Directions for Lower Limb Robotic Exoskeletons
Young, A. J., & Ferris, D. P. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2521160 · Cited by 901
HAL: Hybrid Assistive Limb Based on Cybernics
Sankai, Y. (2010) · Springer Tracts in Advanced Robotics · doi:10.1007/978-3-642-14743-2_3 · Cited by 479
Self-citationIntention-based walking support for paraplegia patients with robot suit HAL
Suzuki, K., Mito, G., Kawamoto, H., Hasegawa, Y., & Sankai, Y. (2007) · Advanced Robotics · doi:10.1163/156855307781746061 · Cited by 474
“Keywords: Robot suit; paraplegia; walking support; intention estimation; floor reaction force.”
BackgroundSelf-citationLower Limb Wearable Robots for Assistance and Rehabilitation: A State of the Art
Huo, W., Mohammed, S., Moreno, J. C., & Amirat, Y. (2016) · IEEE Systems Journal · doi:10.1109/jsyst.2014.2351491 · Cited by 455
Intention-Based Walking Support for Paraplegia Patients with Robot Suit HAL
Suzuki, K., Mito, G., Kawamoto, H., Hasegawa, Y., & Sankai, Y. (2010) · Climbing and Walking Robots · doi:10.5772/8835 · Cited by 400
Self-citationBortole, M., Venkatakrishnan, A., Zhu, F., Moreno, J. C., Francisco, G. E., Pons, J. L., & Contreras-Vidal, J. L. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-015-0048-y · Cited by 347
Fahim, Y. A., Hasani, I. W., Kabba, S., & Ragab, W. M. (2025) · European Journal of Medical Research · doi:10.1186/s40001-025-03196-w · Cited by 329
“These systems utilize surface sensors to detect bioelectrical signals from the user’s body and convert them into coordinated joint movements [90].”
Sit-to-stand and stand-to-sit transfer support for complete paraplegic patients with robot suit HAL
Tsukahara, A., Kawanishi, R., Hasegawa, Y., & Sankai, Y. (2010) · Advanced Robotics · doi:10.1163/016918610x512622 · Cited by 269
“We have proposed a ‘phase sequence’ concept that divides a sequence of a functional motion into motion elements in a short-term phase in order to comprehend and reconstruct a desired motion [5].”
BackgroundSelf-citationA survey of sensor fusion methods in wearable robotics
Novak, D., & Riener, R. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.08.012 · Cited by 252
Powered Hip Exoskeletons Can Reduce the User's Hip and Ankle Muscle Activations During Walking
Lenzi, T., Carrozza, M. C., & Agrawal, S. K. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2248749 · Cited by 215
Oscillator-based assistance of cyclical movements: model-based and model-free approaches
Ronsse, R., Lenzi, T., Vitiello, N., Koopman, B., van Asseldonk, E., De Rossi, S. M. M., van den Kieboom, J., van der Kooij, H., Carrozza, M. C., & Ijspeert, A. J. (2011) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-011-0816-1 · Cited by 188
“The former aims at assisting people affected by chronic movement disorders or neural lesions by providing continuous support giving extra power [20] or increasing movement accuracy [32].”
BackgroundMethodNovel gait adaptation and neuromotor training results using an active leg exoskeleton
Banala, S. K., Agrawal, S. K., Kim, S. H., & Scholz, J. P. (2010) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2010.2041245 · Cited by 165
Kubota, S., Nakata, Y., Eguchi, K., Kawamoto, H., Kamibayashi, K., Sakane, M., Sankai, Y., & Ochiai, N. (2013) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2012.12.020 · Cited by 165
Self-citationHuman–Robot Synchrony: Flexible Assistance Using Adaptive Oscillators
Ronsse, R., Vitiello, N., Lenzi, T., van den Kieboom, J., Carrozza, M. C., & Ijspeert, A. J. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2089629 · Cited by 158
“Recently, this approach was used to restore the physiological walking of physically disabled persons [7]”
MethodBio-inspired upper limb soft exoskeleton to reduce stroke-induced complications
Li, N., Yang, T., Yu, P., Chang, J., Zhao, L., Zhao, X., Elhajj, I. H., Xi, N., & Liu, L. (2018) · Bioinspiration & Biomimetics · doi:10.1088/1748-3190/aad8d4 · Cited by 92
Interactive Control of Lower Limb Exoskeleton Robots: A Review
Zhang, Y.-P., Cao, G.-Z., Li, L.-L., & Diao, D.-F. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3352005 · Cited by 58
“…Cyberdyne Technology Company jointly developed multiple generations of the hybrid robot known as hybrid assistive limb (HAL) for medical assistance [20], [21], [22], which not only can be used to provide assistance to normal people but also can enable people with lower limb dysfunction to regain…”
Background
Metadata
- Authors
- Kawamoto, H., & Sankai, Y.
- Venue
- Advanced Robotics
- Publisher
- Informa UK Limited
- Published
- 2005-01
- Volume
- 19
- Issue
- 7
- Pages
- 717-734
- ISSN
- 0169-1864 (ISSN-L)
- 1568-5535
- OpenAlex
- W2038609344
- Cited by
- 381
- References
- 7
- FWCI
- 4.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.