Protein adsorption to oligo(ethylene glycol) self-assembled monolayers: Experiments with fibrinogen, heparinized plasma, and serum
The DOI matches its Crossref record.
Abstract
Low protein adsorption is believed advantageous for blood-contacting materials and ethylene glycols (EG)-based polymeric compounds are often attached to surfaces for this purpose. In the present study, the adsorption of fibrinogen, serum, and plasma were studied by ellipsometry on a series of well-defined oligo(EG) terminated alkane-thiols self-assembled on gold. The layers were prepared with compounds of the general structure HS-(CH2)15-CONH-EGn, where n = 2, 4, and 6. Methoxy-terminated tri(EG) undecanethiol and hydroxyl-terminated hexadecanethiol self-assembled monolayers (SAMs) were used as references. The results clearly demonstrate that the adsorption depends on the experimental conditions with small amounts of fibrinogen adsorbing from a single protein solution, but larger amounts of proteins from serum and plasma. The adsorption of fibrinogen and blood plasma decreased with an increasing number of EG repeats and was temperature-dependent. Significantly less serum adsorbed to methoxy tri(EG) than to hexa(EG) and more proteins remained on the latter surface after incubation in a sodium dodecyl sulfate (SDS) solution, indicating a looser protein binding to the methoxy-terminated surface. All surfaces adsorbed complement factor 3 (C3) from serum and plasma, although no surface-mediated complement activation was observed. The present study points to the importance of a careful choice of the protein model system before general statements regarding the protein repellant properties of potential surfaces can be made.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ladd, J., Zhang, Z., Chen, S., Hower, J. C., & Jiang, S. (2008) · Biomacromolecules · doi:10.1021/bm701301s · Cited by 808
Surface Chemistry Influences Implant Biocompatibility
Tang, L., Thevenot, P., & Hu, W. (2008) · Current Topics in Medicinal Chemistry · doi:10.2174/156802608783790901 · Cited by 800
Li, Q., Wen, C., Yang, J., Zhou, X., Zhu, Y., Zheng, J., Cheng, G., Bai, J., Xu, T., Ji, J., et al. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00344 · Cited by 790
Biomaterials: Foreign Bodies or Tuners for the Immune Response?
Mariani, E., Lisignoli, G., Borzì, R. M., & Pulsatelli, L. (2019) · International Journal of Molecular Sciences · doi:10.3390/ijms20030636 · Cited by 706
“The complement C3b component can covalently link the -OH group [199,200].”
BackgroundBlood compatibility of surfaces with superlow protein adsorption
Zhang, Z., Zhang, M., Chen, S., Horbett, T. A., Ratner, B. D., & Jiang, S. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.07.039 · Cited by 462
Vaisocherová, H., Yang, W., Zhang, Z., Cao, Z., Cheng, G., Piliarik, M., Homola, J., & Jiang, S. (2008) · Analytical Chemistry · doi:10.1021/ac8015888 · Cited by 409
Proteins, platelets, and blood coagulation at biomaterial interfaces
Xu, L.-C., Bauer, J. W., & Siedlecki, C. A. (2014) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2014.09.040 · Cited by 391
VandeVondele, S., Vörös, J., & Hubbell, J. A. (2003) · Biotechnology and Bioengineering · doi:10.1002/bit.10625 · Cited by 328
Unsworth, L. D., Sheardown, H., & Brash, J. L. (2005) · Langmuir · doi:10.1021/la047672d · Cited by 308
Functionalization of Acetylene-Terminated Monolayers on Si(100) Surfaces: A Click Chemistry Approach
Ciampi, S., Böcking, T., Kilian, K. A., James, M., Harper, J. B., & Gooding, J. J. (2007) · Langmuir · doi:10.1021/la701035g · Cited by 286
Blood coagulation on biomaterials requires the combination of distinct activation processes
Sperling, C., Fischer, M., Maitz, M. F., & Werner, C. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.05.044 · Cited by 281
Surface chemistry to minimize fouling from blood-based fluids
Blaszykowski, C., Sheikh, S., & Thompson, M. (2012) · Chemical Society Reviews · doi:10.1039/c2cs35170f · Cited by 271
Ekblad, T., Bergström, G., Ederth, T., Conlan, S. L., Mutton, R., Clare, A. S., Wang, S., Liu, Y., Zhao, Q., D’Souza, F., et al. (2008) · Biomacromolecules · doi:10.1021/bm800547m · Cited by 269
Self-citationYang, W., Chen, S., Cheng, G., Vaisocherová, H., Xue, H., Li, W., Zhang, J., & Jiang, S. (2008) · Langmuir · doi:10.1021/la801487f · Cited by 258
Chemisorbed poly(propylene sulphide)-based copolymers resist biomolecular interactions
Bearinger, J. P., Terrettaz, S., Michel, R., Tirelli, N., Vogel, H., Textor, M., & Hubbell, J. A. (2003) · Nature Materials · doi:10.1038/nmat851 · Cited by 225
“For example, in biotechnological applications, alkanethiolates have been microcontact printed and used to resist protein adsorption and to constrain cell shape and functio”
MethodTosatti, S., Paul, S. M. D., Askendal, A., VandeVondele, S., Hubbell, J. A., Tengvall, P., & Textor, M. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00420-4 · Cited by 211
Self-citationUnsworth, L. D., Sheardown, H., & Brash, J. L. (2008) · Langmuir · doi:10.1021/la702310t · Cited by 211
Vaisocherová, H., Zhang, Z., Yang, W., Cao, Z., Cheng, G., Taylor, A. D., Piliarik, M., Homola, J., & Jiang, S. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.09.035 · Cited by 194
“…of many sensor echnologies from laboratory use to routine diagnostic practice. arious functionalizable low fouling synthetic materials have been nvestigated including poly(ethylene glycol) (PEG)-based and zwiterionic materials (Benesch et al., 2001; Holmlin et al., 2001; Zhang t al., 2006a,b).”
BackgroundVoicu, R., Boukherroub, R., Bartzoka, V., Ward, T., Wojtyk, J. T. C., & Wayner, D. D. M. (2004) · Langmuir · doi:10.1021/la047886v · Cited by 183
Fundamentals and applications of zwitterionic antifouling polymers
Zhang, Y., Liu, Y., Ren, B., Zhang, D., Xie, S., Chang, Y., Yang, J., Wu, J., Xu, L., & Zheng, J. (2019) · Journal of Physics D: Applied Physics · doi:10.1088/1361-6463/ab2cbc · Cited by 176
“In past decades, solid surfaces coating with zwitterionic polymers have been regarded as a promising strategy for the creation of hydrophilic, biocompatible, inert (noninteracting) surfaces, which generally exhibit high surface resistance to biofouling formation, comparable to or even better than PEG-based antifouling…”
BackgroundVaisocherová, H., Brynda, E., & Homola, J. (2015) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-015-8606-5 · Cited by 161
Metadata
- Authors
- Benesch, J., Svedhem, S., Svensson, S. C. T., Valiokas, R., Liedberg, B., & Tengvall, P.
- Venue
- Journal of Biomaterials Science, Polymer Edition
- Publisher
- Informa UK Limited
- Published
- 2001-01
- Volume
- 12
- Issue
- 6
- Pages
- 581-597
- ISSN
- 0920-5063 (ISSN-L)
- 1568-5624
- OpenAlex
- W1969063115
- Cited by
- 119
- References
- 0
- FWCI
- 5.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.