Measuring fiber alignment in electrospun scaffolds: a user's guide to the 2D fast Fourier transform approach
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
In this study we describe how to use a two-dimensional fast Fourier transform (2D FFT) approach to measure fiber alignment in electrospun materials. This image processing function can be coupled with a variety of imaging modalities to assign an objective numerical value to scaffold anisotropy. A data image of an electrospun scaffold is composed of pixels that depict the spatial organization of the constituent fibers. The 2D FFT function converts this spatial information into a mathematically defined frequency domain that maps the rate at which pixel intensities change across the original data image. This output image also contains quantitative information concerning the orientation of objects in a data image. We discuss the theory and practice of using the frequency plot of the 2D FFT function to measure relative scaffold anisotropy and identify the principal axis of fiber orientation. We note that specific degrees of scaffold anisotropy may represent a critical design feature in the fabrication of tissues that will be subjected to well-defined uniaxial mechanical loads. This structural property may also represent a source of guidance cues that can be exploited to regulate cell phenotype.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospinning process and applications of electrospun fibers
Doshi, J., & Reneker, D. H. (1995) · Journal of Electrostatics · doi:10.1016/0304-3886(95)00041-8 · Cited by 3,209
The effect of processing variables on the morphology of electrospun nanofibers and textiles
Deitzel, J. M., Kleinmeyer, J., Harris, D., & Beck Tan, N. C. (2001) · Polymer · doi:10.1016/s0032-3861(00)00250-0 · Cited by 2,915
Electrospinning of Collagen Nanofibers
Matthews, J. A., Wnek, G. E., Simpson, D. G., & Bowlin, G. L. (2002) · Biomacromolecules · doi:10.1021/bm015533u · Cited by 2,251
Self-citationYang, F., Murugan, R., Wang, S., & Ramakrishna, S. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.06.051 · Cited by 1,804
Polymer nanofibers assembled by electrospinning
Frenot, A., & Chronakis, I. S. (2003) · Current Opinion in Colloid & Interface Science · doi:10.1016/s1359-0294(03)00004-9 · Cited by 1,324
Kenawy, E.-R., Bowlin, G. L., Mansfield, K., Layman, J., Simpson, D. G., Sanders, E. H., & Wnek, G. E. (2002) · Journal of Controlled Release · doi:10.1016/s0168-3659(02)00041-x · Cited by 1,311
Self-citationElectrospinning of Nanofiber Fibrinogen Structures
Wnek, G. E., Carr, M. E., Simpson, D. G., & Bowlin, G. L. (2003) · Nano Letters · doi:10.1021/nl025866c · Cited by 555
Self-citationElectrospinning collagen and elastin: preliminary vascular tissue engineering
Boland, E. (2004) · Frontiers in Bioscience · doi:10.2741/1313 · Cited by 537
Boland, E., Wnek, G., Simpson, D., Pawlowski, K., & Bowlin, G. (2001) · Journal of Macromolecular Science, Part A · doi:10.1081/ma-100108380 · Cited by 464
Self-citationDesign and analysis of tissue engineering scaffolds that mimic soft tissue mechanical anisotropy
Courtney, T., Sacks, M. S., Stankus, J., Guan, J., & Wagner, W. R. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.02.024 · Cited by 416
Ayres, C., Bowlin, G. L., Henderson, S. C., Taylor, L., Shultz, J., Alexander, J., Telemeco, T. A., & Simpson, D. G. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.06.014 · Cited by 307
Self-citationElectrospinning polydioxanone for biomedical applications
Boland, E. D., Coleman, B. D., Barnes, C. P., Simpson, D. G., Wnek, G. E., & Bowlin, G. L. (2005) · Acta Biomaterialia · doi:10.1016/j.actbio.2004.09.003 · Cited by 302
Self-citationA small angle light scattering device for planar connective tissue microstructural analysis
Sacks, M. S., Smith, D. B., & Hiester, E. D. (1997) · Annals of Biomedical Engineering · doi:10.1007/bf02684845 · Cited by 295
Cross-Linking Electrospun Type II Collagen Tissue Engineering Scaffolds with Carbodiimide in Ethanol
Barnes, C. P., Pemble, C. W., Brand, D. D., Simpson, D. G., & Bowlin, G. L. (2007) · Tissue Engineering · doi:10.1089/ten.2006.0292 · Cited by 253
Self-citationTelemeco, T. A., Ayres, C., Bowlin, G. L., Wnek, G. E., Boland, E. D., Cohen, N., Baumgarten, C. M., Mathews, J., & Simpson, D. G. (2005) · Acta Biomaterialia · doi:10.1016/j.actbio.2005.04.006 · Cited by 235
Self-citationThe use of AC potentials in electrospraying and electrospinning processes
Kessick, R., Fenn, J., & Tepper, G. (2004) · Polymer · doi:10.1016/j.polymer.2004.02.056 · Cited by 224
Electrospun polydioxanone–elastin blends: potential for bioresorbable vascular grafts
Sell, S. A., McClure, M. J., Barnes, C. P., Knapp, D. C., Walpoth, B. H., Simpson, D. G., & Bowlin, G. L. (2006) · Biomedical Materials · doi:10.1088/1748-6041/1/2/004 · Cited by 216
Self-citationSacks, M. S., & Schoen, F. J. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10293 · Cited by 179
Correction of uneven illumination (vignetting) in digital microscopy images
Leong, F. J. W.-M. (2003) · Journal of Clinical Pathology · doi:10.1136/jcp.56.8.619 · Cited by 176
Automated measurement of myofiber disarray in transgenic mice with ventricular expression ofras
Karlon, W. J., Covell, J. W., McCulloch, A. D., Hunter, J. J., & Omens, J. H. (1998) · The Anatomical Record · doi:10.1002/(sici)1097-0185(199812)252:4<612::aid-ar12>3.0.co;2-1 · Cited by 153
Simpson, D. G., Majeski, M., Borg, T. K., & Terracio, L. (1999) · Circulation Research · doi:10.1161/01.res.85.10.e59 · Cited by 113
Self-citationvan Zuijlen, P. P. M., de Vries, H. J. C., Lamme, E. N., Coppens, J. E., van Marle, J., Kreis, R. W., & Middelkoop, E. (2002) · The Journal of Pathology · doi:10.1002/path.1219 · Cited by 100
Chow, W. N., Simpson, D. G., Bigbee, J. W., & Colello, R. J. (2007) · Neuron Glia Biology · doi:10.1017/s1740925x07000580 · Cited by 94
Self-citationTissue-engineering scaffolds: can we re-engineer mother nature?
Simpson, D. G., & Bowlin, G. L. (2005) · Expert Review of Medical Devices · doi:10.1586/17434440.3.1.9 · Cited by 32
Self-citation
Cited by
Accordion-like honeycombs for tissue engineering of cardiac anisotropy
Engelmayr, G. C., Cheng, M., Bettinger, C. J., Borenstein, J. T., Langer, R., & Freed, L. E. (2008) · Nature Materials · doi:10.1038/nmat2316 · Cited by 848
Electrospinning jets and nanofibrous structures
Garg, K., & Bowlin, G. L. (2011) · Biomicrofluidics · doi:10.1063/1.3567097 · Cited by 474
Self-citationBudde, M. D., Janes, L., Gold, E., Turtzo, L. C., & Frank, J. A. (2011) · Brain · doi:10.1093/brain/awr161 · Cited by 408
Saino, E., Focarete, M. L., Gualandi, C., Emanuele, E., Cornaglia, A. I., Imbriani, M., & Visai, L. (2011) · Biomacromolecules · doi:10.1021/bm200248h · Cited by 285
Remote Magnetic Orientation of 3D Collagen Hydrogels for Directed Neuronal Regeneration
Antman-Passig, M., & Shefi, O. (2016) · Nano Letters · doi:10.1021/acs.nanolett.6b00131 · Cited by 283
Metadata
- Authors
- Ayres, C. E., Jha, B. S., Meredith, H., Bowman, J. R., Bowlin, G. L., Henderson, S. C., & Simpson, D. G.
- Venue
- Journal of Biomaterials Science, Polymer Edition
- Publisher
- Informa UK Limited
- Published
- 2008-01
- Volume
- 19
- Issue
- 5
- Pages
- 603-621
- ISSN
- 0920-5063 (ISSN-L)
- 1568-5624
- OpenAlex
- W2088686740
- Cited by
- 275
- References
- 24
- FWCI
- 4.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.