Mouth leak with nasal continuous positive airway pressure increases nasal airway resistance.
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Nasal congestion, dry nose and throat, and sore throat affect approximately 40% of patients using nasal continuous positive airway pressure (CPAP). The mechanisms causing nasal symptoms are unclear, but mouth leaks causing high unidirectional nasal airflow may be important. We conducted a study to investigate the effects of mouth leak and the influence of humidification on nasal resistance in normal subjects. Nasal resistance was measured with posterior rhinomanometry in six normal subjects who deliberately produced a mouth leak for 10 min while using nasal CPAP. Nasal resistance was measured regularly for 20 min after the challenge. A series of tests were performed using air at differing temperatures and humidities. There was no change in nasal resistance when subjects breathed through their noses while on CPAP, but a mouth leak caused a large increase in resistance (at a flow of 0.5 L/s) from a baseline mean of 2.21 cm H2O/L/s to a maximum mean of 7.52 cm H2O/L/s at 1 min after the challenge. Use of a cold passover humidifier caused little change in the response (maximum mean: 8.27 cm H2O/L/s), but a hot water bath humidifier greatly attenuated the magnitude (maximum mean: 4.02 cm H2O/L/s) and duration of the response. Mouth leak with nasal CPAP leads to high unidirectional nasal airflow, which causes a large increase in nasal resistance. This response can be largely prevented by fully humidifying the inspired air.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Partitioning of respiratory flow resistance in man
Ferris, B. G., Mead, J., & Opie, L. H. (1964) · Journal of Applied Physiology · doi:10.1152/jappl.1964.19.4.653 · Cited by 448
Obstructive apneas during sleep in patients with seasonal allergic rhinitis.
(1982) · PubMed · doi:10.1164/arrd.1982.126.4.625 · Cited by 277
Togias, A. G., Naclerio, R. M., Proud, D., Fish, J. E., Adkinson, N. F., Kagey-Sobotka, A., Norman, P. S., & Lichtenstein, L. M. (1985) · Journal of Clinical Investigation · doi:10.1172/jci112113 · Cited by 261
Oronasal distribution of respiratory airflow
Niinimaa, V., Cole, P., & Shephard, R. J. (1981) · Respiration Physiology · doi:10.1016/0034-5687(81)90089-x · Cited by 184
Humidification of Inspired Air
Han, Y. H., & Lowe, H. J. (1968) · JAMA · doi:10.1001/jama.1968.03140390031008 · Cited by 67
Nasal flow-resistive responses to challenge with cold dry air
Strohl, K. P., Arnold, J. L., Decker, M. J., Hoekje, P. L., & McFadden, E. R. (1992) · Journal of Applied Physiology · doi:10.1152/jappl.1992.72.4.1243 · Cited by 31
Cited by
Adherence to Continuous Positive Airway Pressure Therapy: The Challenge to Effective Treatment
Weaver, T. E., & Grunstein, R. R. (2008) · Proceedings of the American Thoracic Society · doi:10.1513/pats.200708-119mg · Cited by 1,680
MEHTA, S., & HILL, N. S. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.2.9906116 · Cited by 890
Long-term Use of CPAP Therapy for Sleep Apnea/Hypopnea Syndrome
McARDLE, N., DEVEREUX, G., HEIDARNEJAD, H., ENGLEMAN, H. M., MACKAY, T. W., & DOUGLAS, N. J. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.159.4.9807111 · Cited by 820
Improving CPAP use by patients with the sleep apnoea/hypopnoea syndrome (SAHS)
Engleman, H. M., & Wild, M. R. (2003) · Sleep Medicine Reviews · doi:10.1053/smrv.2001.0197 · Cited by 473
Heated Humidified High-Flow Nasal Oxygen in Adults
Spoletini, G., Alotaibi, M., Blasi, F., & Hill, N. S. (2015) · Chest · doi:10.1378/chest.14-2871 · Cited by 406
Carron, M., Freo, U., BaHammam, A. S., Dellweg, D., Guarracino, F., Cosentini, R., Feltracco, P., Vianello, A., Ori, C., & Esquinas, A. (2013) · British Journal of Anaesthesia · doi:10.1093/bja/aet070 · Cited by 312
Massie, C. A., Hart, R. W., Peralez, K., & Richards, G. N. (1999) · Chest · doi:10.1378/chest.116.2.403 · Cited by 308
Self-citationPositive Airway Pressure Treatment for Obstructive Sleep Apnea
Kakkar, R. K., & Berry, R. B. (2007) · Chest · doi:10.1378/chest.06-2432 · Cited by 258
A European survey of noninvasive ventilation practices
Crimi, C., Noto, A., Princi, P., Esquinas, A., & Nava, S. (2010) · European Respiratory Journal · doi:10.1183/09031936.00123509 · Cited by 209
Physiologic Effects of High-Flow Nasal Cannula Oxygen in Critical Care Subjects
Vargas, F., Saint-Leger, M., Boyer, A., Bui, N. H., & Hilbert, G. (2015) · Respiratory Care · doi:10.4187/respcare.03814 · Cited by 199
“The difference between HFNC and CPAP was not significant (23 [18–25] breaths/min versus 21 [21–32] breaths/min, P .”
BackgroundEffect of mouth leak on effectiveness of nasal bilevel ventilatory assistance and sleep architecture
Teschler, H., Stampa, J., Ragette, R., Konietzko, N., & Berthon-Jones, M. (1999) · European Respiratory Journal · doi:10.1183/09031936.99.14612519 · Cited by 196
Self-citationZozula, R., & Rosen, R. (2001) · Current Opinion in Pulmonary Medicine · doi:10.1097/00063198-200111000-00005 · Cited by 189
Cuquemelle, E., Pham, T., Papon, J.-F., Louis, B., Danin, P.-E., & Brochard, L. (2012) · Respiratory Care · doi:10.4187/respcare.01681 · Cited by 182
Windisch, W., Dreher, M., Geiseler, J., Siemon, K., Brambring, J., Dellweg, D., Grolle, B., Hirschfeld, S., Köhnlein, T., Mellies, U., et al. (2017) · Pneumologie · doi:10.1055/s-0043-118040 · Cited by 175
“[97] Richards GN, Cistulli PA, Ungar RG et al.”
BackgroundEquipment needs for noninvasive mechanical ventilation
Schönhofer, B., & Sortor-Leger, S. (2002) · European Respiratory Journal · doi:10.1183/09031936.02.00404202 · Cited by 169
“It has been shown that despite a severe mouth leak, heated humidification significantly increased relative humidity in the airways [49] and reduced nasal resistance [47].”
Effect of the humidification device on the work of breathing during noninvasive ventilation
Lellouche, F., Maggiore, S. M., Deye, N., Taillé, S., Pigeot, J., Harf, A., & Brochard, L. (2002) · Intensive Care Medicine · doi:10.1007/s00134-002-1518-9 · Cited by 165
Treatment of obstructive sleep apnoea with nasal continuous positive airway pressure in stroke
Wessendorf, T. E., Wang, Y.-;., Thilmann, A. F., Sorgenfrei, U., Konietzko, N., & Teschler, H. (2001) · European Respiratory Journal · doi:10.1183/09031936.01.00057201 · Cited by 161
“In addition, the presence of a facial palsy may contribute to significant mouth leak, known to cause nasal and pharyngeal mucosal problems, worsening of sleep quality and poorer compliance [12, 13].”
BackgroundMador, M. J., Krauza, M., Pervez, A., Pierce, D., & Braun, M. (2005) · Chest · doi:10.1378/chest.128.4.2151 · Cited by 150
JANSON, C., NÖGES, E., SVEDBERG-BRANDT, S., & LINDBERG, E. (2000) · Respiratory Medicine · doi:10.1053/rmed.1999.0703 · Cited by 121
Rowland, S., Aiyappan, V., Hennessy, C., Catcheside, P., Chai-Coezter, C. L., McEvoy, R. D., & Antic, N. A. (2018) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.6892 · Cited by 105
Pressure-Relief Continuous Positive Airway Pressure vs Constant Continuous Positive Airway Pressure
Nilius, G., Happel, A., Domanski, U., & Ruhle, K.-H. (2006) · Chest · doi:10.1378/chest.130.4.1018 · Cited by 99
Humidified nasal continuous positive airway pressure in obstructive sleep apnoea
Neill, A. M., Wai, H. S., Bannan, S. P. T., Beasley, C. R., Weatherall, M., & Campbell, A. J. (2003) · European Respiratory Journal · doi:10.1183/09031936.03.00035603 · Cited by 97
Ryan, S., Doherty, L. S., Nolan, G. M., & McNicholas, W. T. (2009) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.27596 · Cited by 87
Nasopharyngeal Symptoms in Patients with Obstructive Sleep Apnea Syndrome
Brander, P. E., Soirinsuo, M., & Lohela, P. (1999) · Respiration · doi:10.1159/000029354 · Cited by 83
Nasal inflammation in sleep apnoea patients using CPAP and effect of heated humidification
Koutsourelakis, I., Vagiakis, E., Perraki, E., Karatza, M., Magkou, C., Kopaka, M., Roussos, C., & Zakynthinos, S. (2011) · European Respiratory Journal · doi:10.1183/09031936.00036910 · Cited by 72
“Previous studies have assessed the role of CPAP on nasal airway of healthy volunteers [8, 9, 10, 16] and in a rodent model [11], and have also evaluated the effect of different forms of humidification on nasal symptoms and adherence in OSA patients [13, 14, 15, 22].”
BackgroundMethodInfluentialRoutine use of humidification with nasal continuous positive airway pressure
Worsnop, C. J., Miseski, S., & Rochford, P. D. (2010) · Internal Medicine Journal · doi:10.1111/j.1445-5994.2009.01969.x · Cited by 38
Zhu, D., Wu, M., Cao, Y., Lin, S., Xuan, N., Zhu, C., Li, W., & Shen, H. (2018) · PLOS ONE · doi:10.1371/journal.pone.0207994 · Cited by 18
Elwany, S., Bahgat, A. Y., Ibrahim, M., & Bazak, R. (2022) · Irish Journal of Medical Science (1971 -) · doi:10.1007/s11845-021-02896-6 · Cited by 14
Metadata
- Authors
- Richards, G. N., Cistulli, P. A., Ungar, R. G., Berthon-Jones, M., & Sullivan, C. E.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 1996-07
- Volume
- 154
- Issue
- 1
- Pages
- 182-186
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2012688625
- Cited by
- 281
- References
- 6
- FWCI
- 2.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.