The Tension–Time Index and the Frequency/ Tidal Volume Ratio Are the Major Pathophysiologic Determinants of Weaning Failure and Success
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
We have previously shown (Am. J. Respir. Crit. Care Med. 1995;152:1248-1255) that in patients needing mechanical ventilation, the load imposed on the inspiratory muscles is excessive relative to their neuromuscular capacity. We have therefore hypothesized that weaning failure may occur because at the time of the trial of spontaneous breathing there is insufficient reduction of the inspiratory load. We therefore prospectively studied patients who initially had failed to wean from mechanical ventilation (F) but had successful weaning (S) on a later occasion. Compared with S, during F patients had greater intrinsic positive end-expiratory pressure (6. 10 +/- 2.45 versus 3.83 +/- 2.69 cm H2O), dynamic hyperinflation (327 +/- 180 versus 213 +/- 175 ml), total resistance (Rmax, 14.14 +/- 4.95 versus 11.19 +/- 4.01 cm H2O/L/s), ratio of mean to maximum inspiratory pressure (0.46 +/- 0.1 versus 0.31 +/- 0.08), tension time index (TTI, 0.162 +/- 0.032 versus 0.102 +/- 0.023) and power (315 +/- 153 versus 215 +/- 75 cm H2O x L/min), less maximum inspiratory pressure (42.3 +/- 12.7 versus 53.8 +/- 15.1 cm H2O), and a breathing pattern that was more rapid and shallow (ratio of frequency to tidal volume, f/VT 98 +/- 38 versus 62 +/- 21 breaths/min/L). To clarify on pathophysiologic grounds what determines inability to wean from mechanical ventilation, we performed multiple logistic regression analysis with the weaning outcome as the dependent variable. The TTI and the f/VT ratio were the only significant variables in the model. We conclude that the TTI and the f/VT are the major pathophysiologic determinants underlying the transition from weaning failure to weaning success.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Simple Sequentially Rejective Multiple Test Procedure
(1979) · Scandinavian Journal of Statistics · doi:10.2307/4615733 · Cited by 21,526 · cited 1×
“Due to the large number of variables compared, a Bonferroni-type adjustment was carried out using Holmes’ procedure ( 14 ).”
MethodScandinavian Journal of Statistics
Rosén, B. (2005) · Encyclopedia of Statistical Sciences · doi:10.1002/0471667196.ess2351.pub2 · Cited by 3,595
Yang, K. L., & Tobin, M. J. (1991) · New England Journal of Medicine · doi:10.1056/nejm199105233242101 · Cited by 1,378
The Risk of Determining Risk with Multivariable Models
Concato, J., Feinstein, A. R., & Holford, T. R. (1993) · Annals of Internal Medicine · doi:10.7326/0003-4819-118-3-199302010-00009 · Cited by 1,115
Effect of pressure and timing of contraction on human diaphragm fatigue
Bellemare, F., & Grassino, A. (1982) · Journal of Applied Physiology · doi:10.1152/jappl.1982.53.5.1190 · Cited by 644
Petrof, B. J., Legaré, M., Goldberg, P., Milic-Emili, J., & Gottfried, S. B. (1990) · American Review of Respiratory Disease · doi:10.1164/ajrccm/141.2.281 · Cited by 486
Jubran, A., & Tobin, M. J. (1997) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.155.3.9117025 · Cited by 463
Analysis of the behavior of the respiratory system with constant inspiratory flow
Bates, J. H., Rossi, A., & Milic-Emili, J. (1985) · Journal of Applied Physiology · doi:10.1152/jappl.1985.58.6.1840 · Cited by 441
(1987) · Journal of Critical Care · doi:10.1016/0883-9441(87)90022-0 · Cited by 335
Fatigue of inspiratory muscles and their synergic behavior
Roussos, C., Fixley, M., Gross, D., & Macklem, P. T. (1979) · Journal of Applied Physiology · doi:10.1152/jappl.1979.46.5.897 · Cited by 259
Self-citation
Cited by
Spruit, M. A., Singh, S. J., Garvey, C., ZuWallack, R., Nici, L., Rochester, C., Hill, K., Holland, A. E., Lareau, S. C., Man, W. D.-C., et al. (2013) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201309-1634st · Cited by 3,938
ATS/ERS Statement on Respiratory Muscle Testing
(2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.166.4.518 · Cited by 2,841
Evidence-Based Guidelines for Weaning and Discontinuing Ventilatory Support
MacIntyre, N. R. (2001) · Chest · doi:10.1378/chest.120.6_suppl.375s · Cited by 1,240
Disorders of the Respiratory Muscles
Laghi, F., & Tobin, M. J. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.2206020 · Cited by 687
Evolution of Diaphragm Thickness during Mechanical Ventilation. Impact of Inspiratory Effort
Goligher, E. C., Fan, E., Herridge, M. S., Murray, A., Vorona, S., Brace, D., Rittayamai, N., Lanys, A., Tomlinson, G., Singh, J. M., et al. (2015) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201503-0620oc · Cited by 608
Management of Patients Requiring Prolonged Mechanical Ventilation
MacIntyre, N. R., Epstein, S. K., Carson, S., Scheinhorn, D., Christopher, K., & Muldoon, S. (2005) · Chest · doi:10.1378/chest.128.6.3937 · Cited by 533
Ventilator-induced Diaphragmatic Dysfunction
Vassilakopoulos, T., & Petrof, B. J. (2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200304-489cp · Cited by 520
Self-citationPredicting Success in Weaning From Mechanical Ventilation
Meade, M., Guyatt, G., Cook, D., Griffith, L., Sinuff, T., Kergl, C., Mancebo, J., Esteban, A., & Epstein, S. (2001) · Chest · doi:10.1378/chest.120.6_suppl.400s · Cited by 424
Is Weaning Failure Caused by Low-Frequency Fatigue of the Diaphragm?
Laghi, F., Cattapan, S. E., Jubran, A., Parthasarathy, S., Warshawsky, P., Choi, Y.-S. A., & Tobin, M. J. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200210-1246oc · Cited by 359
Diaphragm ultrasound as a new index of discontinuation from mechanical ventilation
Ferrari, G., De Filippi, G., Elia, F., Panero, F., Volpicelli, G., & Aprà, F. (2014) · Critical Ultrasound Journal · doi:10.1186/2036-7902-6-8 · Cited by 306
Martin, A. D., Smith, B. K., Davenport, P. D., Harman, E., Gonzalez-Rothi, R. J., Baz, M., Layon, A. J., Banner, M. J., Caruso, L. J., Deoghare, H., et al. (2011) · Critical Care · doi:10.1186/cc10081 · Cited by 294
Epstein, S. (2002) · Intensive Care Medicine · doi:10.1007/s00134-002-1268-8 · Cited by 288
Goligher, E. C., Brochard, L. J., Reid, W. D., Fan, E., Saarela, O., Slutsky, A. S., Kavanagh, B. P., Rubenfeld, G. D., & Ferguson, N. D. (2019) · The Lancet Respiratory Medicine · doi:10.1016/s2213-2600(18)30366-7 · Cited by 275
Farghaly, S., & Hasan, A. A. (2017) · Australian Critical Care · doi:10.1016/j.aucc.2016.03.004 · Cited by 159
Vidotto, M. C., Sogame, L. C. M., Calciolari, C. C., Nascimento, O. A., & Jardim, J. R. (2008) · Neurocritical Care · doi:10.1007/s12028-008-9059-x · Cited by 47
Gao, Y., Xu, A., Hu, P. J.-H., & Cheng, T.-H. (2017) · Decision Support Systems · doi:10.1016/j.dss.2017.01.007 · Cited by 26
Metadata
- Authors
- VASSILAKOPOULOS, T., ZAKYNTHINOS, S., & ROUSSOS, C.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 1998-08-01
- Volume
- 158
- Issue
- 2
- Pages
- 378-385
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2031027743
- Cited by
- 297
- References
- 24
- FWCI
- 8.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.