CoChat

Noninvasive Ventilation Improves Preoxygenation before Intubation of Hypoxic Patients

Baillard, Christophe, Fosse, Jean-Philippe, Sebbane, Mustapha, Chanques, Gérald, Vincent, Francçois, Courouble, Patricia, Cohen, Yves, Eledjam, Jean-Jacques, Adnet, Frédéric, Jaber, Samir · 2006 · American Journal of Respiratory and Critical Care Medicine
Cited by 478

The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.

Abstract

RATIONALE: Critically ill patients are predisposed to oxyhemoglobin desaturation during intubation. OBJECTIVES: To find out whether noninvasive ventilation (NIV), as a preoxygenation method, is more effective at reducing arterial oxyhemoglobin desaturation than usual preoxygenation during orotracheal intubation in hypoxemic, critically ill patients. METHODS: Prospective randomized study performed in two surgical/medical intensive care units (ICUs). Preoxygenation was performed, before a rapid sequence intubation, for a 3-min period using a nonrebreather bag-valve mask (control group) or pressure support ventilation delivered by an ICU ventilator through a face mask (NIV group) according to the randomization. MEASUREMENTS AND MAIN RESULTS: The control (n = 26) and NIV (n = 27) groups were similar in terms of age, disease severity, diagnosis at admission, and pulse oxymetry values (Sp(O(2))) before preoxygenation. At the end of preoxygenation, Sp(O(2)) was higher in the NIV group as compared with the control group (98 +/- 2 vs. 93 +/- 6%, p < 0.001). During the intubation procedure, the lower Sp(O(2)) values were observed in the control group (81 +/- 15 vs. 93 +/- 8%, p < 0.001). Twelve (46%) patients in the control group and two (7%) in the NIV group had an Sp(O(2)) below 80% (p < 0.01). Five minutes after intubation, Sp(O(2)) values were still better in the NIV group as compared with the control group (98 +/- 2 vs. 94 +/- 6%, p < 0.01). Regurgitations (n = 3; 6%) and new infiltrates on post-procedure chest X ray (n = 4; 8%) were observed with no significant difference between groups. CONCLUSION: For the intubation of hypoxemic patients, preoxygenation using NIV is more effective at reducing arterial oxyhemoglobin desaturation than the usual method.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/rccm.200509-1507oc

Cites

27 of 27 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 478

Metadata

Authors
Baillard, C., Fosse, J.-P., Sebbane, M., Chanques, G., Vincent, F., Courouble, P., Cohen, Y., Eledjam, J.-J., Adnet, F., & Jaber, S.
Venue
American Journal of Respiratory and Critical Care Medicine
Published
2006-07-15
Volume
174
Issue
2
Pages
171-177
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W2119925301
Cited by
478
References
27
FWCI
18.15
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.