CoChat

Nasal High-Flow versus Venturi Mask Oxygen Therapy after Extubation. Effects on Oxygenation, Comfort, and Clinical Outcome

Maggiore, Salvatore Maurizio, Idone, Francesco Antonio, Vaschetto, Rosanna, Festa, Rossano, Cataldo, Andrea, Antonicelli, Federica, Montini, Luca, De Gaetano, Andrea, Navalesi, Paolo, Antonelli, Massimo · 2014 · American Journal of Respiratory and Critical Care Medicine
Cited by 546

The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.

Abstract

RATIONALE: Oxygen is commonly administered after extubation. Although several devices are available, data about their clinical efficacy are scarce. OBJECTIVES: To compare the effects of the Venturi mask and the nasal high-flow (NHF) therapy on PaO2/FiO2SET ratio after extubation. Secondary endpoints were to assess effects on patient discomfort, adverse events, and clinical outcomes. METHODS: Randomized, controlled, open-label trial on 105 patients with a PaO2/FiO2 ratio less than or equal to 300 immediately before extubation. The Venturi mask (n = 52) or NHF (n = 53) were applied for 48 hours postextubation. MEASUREMENTS AND MAIN RESULTS: PaO2/FiO2SET, patient discomfort caused by the interface and by symptoms of airways dryness (on a 10-point numerical rating scale), interface displacements, oxygen desaturations, need for ventilator support, and reintubation were assessed up to 48 hours after extubation. From the 24th hour, PaO2/FiO2SET was higher with the NHF (287 ± 74 vs. 247 ± 81 at 24 h; P = 0.03). Discomfort related both to the interface and to airways dryness was better with NHF (respectively, 2.6 ± 2.2 vs. 5.1 ± 3.3 at 24 h, P = 0.006; 2.2 ± 1.8 vs. 3.7 ± 2.4 at 24 h, P = 0.002). Fewer patients had interface displacements (32% vs. 56%; P = 0.01), oxygen desaturations (40% vs. 75%; P < 0.001), required reintubation (4% vs. 21%; P = 0.01), or any form of ventilator support (7% vs. 35%; P < 0.001) in the NHF group. CONCLUSIONS: Compared with the Venturi mask, NHF results in better oxygenation for the same set FiO2 after extubation. Use of NHF is associated with better comfort, fewer desaturations and interface displacements, and a lower reintubation rate. Clinical trial registered with www.clinicaltrials.gov (NCT 01575353).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/rccm.201402-0364oc

Cites

31 of 31 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 546

Metadata

Authors
Maggiore, S. M., Idone, F. A., Vaschetto, R., Festa, R., Cataldo, A., Antonicelli, F., Montini, L., De Gaetano, A., Navalesi, P., & Antonelli, M.
Venue
American Journal of Respiratory and Critical Care Medicine
Published
2014-08-01
Volume
190
Issue
3
Pages
282-288
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W2170095922
Cited by
546
References
31
FWCI
36.59
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.