The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Compensation of corneal aberrations by the internal optics in the human eye
Open accessAbstract
The objective was to study the relative contribution of the optical aberrations of the cornea and the internal ocular optics (with the crystalline lens as the main component) to overall aberrations in the human eye. Three sets of wave-front aberration data were independently measured in the eyes of young subjects: for the anterior surface of the cornea, the complete eye, and internal ocular optics. The amount of aberration of both the cornea and internal optics was found to be larger than for the complete eye, indicating that the first surface of the cornea and internal optics partially compensate for each other's aberrations and produce an improved retinal image. This result has a number of practical implications. For example, it shows the limitation of corneal topography as a guide for new refractive procedures and provides a strong endorsement of the value of ocular wave-front sensing for those applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Optics: 60th Anniversary Edition
Born, M., & Wolf, E. (2019) · Cambridge University Press eBooks · doi:10.1017/9781108769914 · Cited by 26,251
Introduction to Fourier optics
Goodman, J. W. (1968) · Cited by 10,608
Zernike polynomials and atmospheric turbulence*
Noll, R. J. (1976) · Journal of the Optical Society of America · doi:10.1364/josa.66.000207 · Cited by 2,771
Supernormal vision and high-resolution retinal imaging through adaptive optics
Liang, J., Williams, D. R., & Miller, D. T. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.002884 · Cited by 1,454
Self-citationLiang, J., Grimm, B., Goelz, S., & Bille, J. F. (1994) · Journal of the Optical Society of America A · doi:10.1364/josaa.11.001949 · Cited by 1,195
Aberrations and retinal image quality of the normal human eye
Liang, J., & Williams, D. R. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.002873 · Cited by 764
Self-citationPresbyopia and the optical changes in the human crystalline lens with age
Glasser, A., & Campbell, M. C. W. (1998) · Vision Research · doi:10.1016/s0042-6989(97)00102-8 · Cited by 601
Analysis of the performance of the Hartmann–Shack sensor in the human eye
Prieto, P. M., Vargas-Martı́n, F., Goelz, S., & Artal, P. (2000) · Journal of the Optical Society of America A · doi:10.1364/josaa.17.001388 · Cited by 298
Self-citationAverage optical performance of the human eye as a function of age in a normal population.
Guirao, A., González, C., Redondo, M., Geraghty, E., Norrby, S., & Artal, P. (1999) · PubMed · Cited by 274
Self-citation(1857) · Scientific American · doi:10.1038/scientificamerican01171857-149a · Cited by 250
Cited by
A New Intraocular Lens Design to Reduce Spherical Aberration of Pseudophakic Eyes
Holladay, J. T., Piers, P. A., Koranyi, G., van der Mooren, M., & Norrby, N. E. S. (2002) · Journal of Refractive Surgery · doi:10.3928/1081-597x-20021101-04 · Cited by 560
Contribution of the cornea and internal surfaces to the change of ocular aberrations with age
Artal, P., Berrio, E., Guirao, A., & Piers, P. (2002) · Journal of the Optical Society of America A · doi:10.1364/josaa.19.000137 · Cited by 494
Self-citationIMI – Report on Experimental Models of Emmetropization and Myopia
Troilo, D., Smith, E. L., Nickla, D. L., Ashby, R., Tkatchenko, A. V., Ostrin, L. A., Gawne, T. J., Pardue, M. T., Summers, J. A., Kee, C.-S., et al. (2019) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.18-25967 · Cited by 487
Adaptive-optics ultrahigh-resolution optical coherence tomography
Hermann, B., Fernández, E. J., Unterhuber, A., Sattmann, H., Fercher, A. F., Drexler, W., Prieto, P. M., & Artal, P. (2004) · Optics Letters · doi:10.1364/ol.29.002142 · Cited by 379
Self-citationNeural compensation for the eye’s optical aberrations
Artal, P., Chen, L., Fernández, E. J., Singer, B., Manzanera, S., & Williams, D. R. (2004) · Journal of Vision · doi:10.1167/4.4.4 · Cited by 332
Self-citationOptical Coherence Tomography: History, Current Status, and Laboratory Work
Gabriele, M. L., Wollstein, G., Ishikawa, H., Kagemann, L., Xu, J., Folio, L. S., & Schuman, J. S. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-6312 · Cited by 310
Wavefront optics and retinal image quality
Oliveira, C. M., & Franco, S. (2013) · Optometry Reports · doi:10.4081/optometry.2013.e1 · Cited by 1
Metadata
- Authors
- Artal, P., Guirao, A., Berrio, E., & Williams, D. R.
- Venue
- Journal of Vision
- Published
- 2001-05-01
- Volume
- 1
- Issue
- 1
- Pages
- 1
- ISSN
- 1534-7362 (ISSN-L)
- OpenAlex
- W2140170699
- Cited by
- 434
- References
- 13
- FWCI
- 9.19
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.