A five-primary photostimulator suitable for studying intrinsically photosensitive retinal ganglion cell functions in humans
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Intrinsically photosensitive retinal ganglion cells (ipRGCs) can respond to light directly through self-contained photopigment, melanopsin. IpRGCs also receive synaptic inputs from rods and cones. Thus, studying ipRGC functions requires a novel photostimulating method that can account for all of the photoreceptor inputs. Here, we introduced an inexpensive LED-based five-primary photostimulator that can control the excitations of rods, S-, M-, L-cones, and melanopsin-containing ipRGCs in humans at constant background photoreceptor excitation levels, a critical requirement for studying the adaptation behavior of ipRGCs with rod, cone, or melanopsin input. We described the theory and technical aspects (including optics, electronics, software, and calibration) of the five-primary photostimulator. Then we presented two preliminary studies using the photostimulator we have implemented to measure melanopsin-mediated pupil responses and temporal contrast sensitivity function (TCSF). The results showed that the S-cone input to pupil responses was antagonistic to the L-, M- or melanopsin inputs, consistent with an S-OFF and (L + M)-ON response property of primate ipRGCs (Dacey et al., 2005). In addition, the melanopsin-mediated TCSF had a distinctive pattern compared with L + M or S-cone mediated TCSF. Other than controlling individual photoreceptor excitation independently, the five-primary photostimulator has the flexibility in presenting stimuli modulating any combination of photoreceptor excitations, which allows researchers to study the mechanisms by which ipRGCs combine various photoreceptor inputs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Phototransduction by retinal ganglion cells that set the circadian clock
Berson, D. M., Dunn, F. A., & Takao, M. (2002) · Science · doi:10.1126/science.1067262 · Cited by 3,629 · cited 1×
“In addition to the classical rod and cone photoreceptors, a new type of photoreceptor, called intrinsically photosensitive retinal ganglion cells (ipRGCs), was discovered in mammalian inner retinas recently (Berson, Dunn, & Takao, 2002; Hattar, Liao, Takao, Berson, & Yau, 2002).”
Human photoreceptor topography
Curcio, C. A., Sloan, K. R., Kalina, R. E., & Hendrickson, A. E. (1990) · Journal of Comparative Neurology · doi:10.1002/cne.902920402 · Cited by 3,167
Hattar, S., Liao, H.-W., Takao, M., Berson, D. M., & Yau, K.-W. (2002) · Science · doi:10.1126/science.1069609 · Cited by 2,734
Dacey, D. M., Liao, H.-W., Peterson, B. B., Robinson, F. R., Smith, V. C., Pokorny, J., Yau, K.-W., & Gamlin, P. D. (2005) · Nature · doi:10.1038/nature03387 · Cited by 1,333 · cited 9×
“ON response property of primate ipRGCs (Dacey et al., 2005), an antagonistic interaction between S-cone and L-cone contributions to pupillary responses evoked by chromatic flash offset (Kimura & Young, 1999) and opponent melanopsin and S-cone signals in pupillary responses to sinusoidal stimuli…”
InfluentialA Novel Human Opsin in the Inner Retina
Provencio, I., Rodriguez, I. R., Jiang, G., Hayes, W. P., Moreira, E. F., & Rollag, M. D. (2000) · The Journal of Neuroscience · doi:10.1523/jneurosci.20-02-00600.2000 · Cited by 1,290 · cited 1×
“IpRGCs express melanopsin, a photopigment that can respond to light directly (Provencio et al., 2000).”
Measuring and using light in the melanopsin age
Lucas, R. J., Peirson, S. N., Berson, D. M., Brown, T. M., Cooper, H. M., Czeisler, C. A., Figueiro, M. G., Gamlin, P. D., Lockley, S. W., O’Hagan, J. B., et al. (2014) · Trends in Neurosciences · doi:10.1016/j.tins.2013.10.004 · Cited by 1,278
Hattar, S., Lucas, R. J., Mrosovsky, N., Thompson, S., Douglas, R. H., Hankins, M. W., Lem, J., Biel, M., Hofmann, F., Foster, R. G., et al. (2003) · Nature · doi:10.1038/nature01761 · Cited by 1,245 · cited 2×
“IpRGCs project to brain areas associated with non-imageforming functions, such as the SCN for circadian photoentrainment (Hattar et al., 2003; Ruby et al., 2002) and the olivary pretectal nucleus (OPN) for controlling pupil size (Clarke, Zhang, & Gamlin, 2003; Hattar et al.”
Human and macaque pupil responses driven by melanopsin-containing retinal ganglion cells
Gamlin, P. D. R., McDougal, D. H., Pokorny, J., Smith, V. C., Yau, K.-W., & Dacey, D. M. (2007) · Vision Research · doi:10.1016/j.visres.2006.12.015 · Cited by 617 · cited 1×
“This pattern was similar to a recent finding that the melanopsin-mediated, post-illumination pupil response (PIPR, Gamlin et al., 2007; McDougal & Gamlin, 2010) was independent of temporal frequency (Joyce, Feigl, Cao, & Zele, 2015).”
Enezi, J. A., Revell, V., Brown, T., Wynne, J., Schlangen, L., & Lucas, R. (2011) · Journal of Biological Rhythms · doi:10.1177/0748730411409719 · Cited by 278 · cited 1×
“The melanopsin-medi-ated ipRGC excitation (I) is computed according to the melanopsin spectral sensitivity function that accounts for cornea and lens spectral filtering, mel ð k Þ (al Enezi et al., 2011).”
Melanopsin-Based Brightness Discrimination in Mice and Humans
Brown, T. M., Tsujimura, S.-I., Allen, A. E., Wynne, J., Bedford, R., Vickery, G., Vugler, A., & Lucas, R. J. (2012) · Current Biology · doi:10.1016/j.cub.2012.04.039 · Cited by 256
Cited by
Melanopsin contributions to non-visual and visual function
Spitschan, M. (2019) · Current Opinion in Behavioral Sciences · doi:10.1016/j.cobeha.2019.06.004 · Cited by 146
Spitschan, M., Bock, A. S., Ryan, J., Frazzetta, G., Brainard, D. H., & Aguirre, G. K. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1711522114 · Cited by 116
Cone and melanopsin contributions to human brightness estimation
Zele, A. J., Adhikari, P., Feigl, B., & Cao, D. (2018) · Journal of the Optical Society of America A · doi:10.1364/josaa.35.000b19 · Cited by 97
Self-citationMelanopsin- and L-cone–induced pupil constriction is inhibited by S- and M-cones in humans
Woelders, T., Leenheers, T., Gordijn, M. C. M., Hut, R. A., Beersma, D. G. M., & Wams, E. J. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1716281115 · Cited by 81
“It is worth noting that, under a sine-wave modulation of M-cone illuminance, pupil diameter was previously not found to be out of phase with the M-cone illuminance modulation as we report here (19).”
BackgroundEvidence for an impact of melanopsin activation on unique white perception
Cao, D., Chang, A., & Gai, S. (2018) · Journal of the Optical Society of America A · doi:10.1364/josaa.35.00b287 · Cited by 51
“Details of the instrument and calibration procedures can be found in our previous publication [18,27].”
Self-citation
Metadata
- Authors
- Cao, D., Nicandro, N., & Barrionuevo, P. A.
- Venue
- Journal of Vision
- Published
- 2015-01-26
- Volume
- 15
- Issue
- 1
- Pages
- 27-27
- ISSN
- 1534-7362 (ISSN-L)
- OpenAlex
- W1967738556
- Cited by
- 101
- References
- 12
- FWCI
- 3.87
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.