CoChat

Multiphoton Autofluorescence and Second-Harmonic Generation Imaging of the Ex Vivo Porcine Eye

Teng, Shu-Wen, Tan, Hsin-Yuan, Peng, Ju-Li, Lin, Huei-Hsing, Kim, Ki Hean, Lo, Wen, Sun, Yen, Lin, Wei-Chou, Lin, Sung-Jan, Jee, Shiou-Hwa, So, Peter T. C., Dong, Chen-Yuan · 2006 · Investigative Opthalmology & Visual Science
Cited by 143

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

PURPOSE: The purpose of this work was to demonstrate the use of the combined imaging modality of multiphoton autofluorescence and second-harmonic generation (SHG) microscopy in obtaining spectrally resolved morphologic features of the cornea, limbus, conjunctiva, and sclera in whole, ex vivo porcine eyes. METHODS: The 780-nm output of a femtosecond, titanium-sapphire laser was used to induce broadband autofluorescence (435-700 nm) and SHG (390 nm) from various regions of the surface of ex vivo porcine eyes. A water-immersion objective was used for convenient imaging of the curved surface of the eye. RESULTS: Multiphoton autofluorescence was useful in identifying cellular structures of the different domains of the ocular surface, and the SHG signal can be used to resolve collagen organization within the cornea stroma and sclera of ex vivo porcine eyes. CONCLUSIONS: Multiphoton autofluorescence and SHG microscopy have been demonstrated to be an effective technique for resolving, respectively, the cellular and collagen structures within the ocular surface of ex vivo porcine eyes. SHG imaging resolved the difference in structural orientations between corneal and sclera collagen fibers. Specifically, the corneal collagen is organized in a depth-dependent fashion, whereas the scleral collagen is randomly packed. Because this technique does not require histologic preparation procedures, it has the potential to be applied for in vivo studies with minimal disturbance to the eye.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.04-1520

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Teng, S.-W., Tan, H.-Y., Peng, J.-L., Lin, H.-H., Kim, K. H., Lo, W., Sun, Y., Lin, W.-C., Lin, S.-J., Jee, S.-H., So, P. T. C., & Dong, C.-Y.
Venue
Investigative Opthalmology & Visual Science
Published
2006-03-01
Volume
47
Issue
3
Pages
1216
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W2124355796
Cited by
143
References
2
FWCI
8.02
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.