The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Automatic Retinal Oximetry
Abstract
PURPOSE: To measure hemoglobin oxygen saturation (SO(2)) in retinal vessels and to test the reproducibility and sensitivity of an automatic spectrophotometric oximeter. METHODS: Specialized software automatically identifies the retinal blood vessels on fundus images, which are obtained with four different wavelengths of light. The software calculates optical density ratios (ODRs) for each vessel. The reproducibility was evaluated by analyzing five repeated measurements of the same vessels. A linear relationship between SO(2) and ODR was assumed and a linear model derived. After calibration, reproducibility and sensitivity were calculated in terms of SO(2). Systemic hyperoxia (n = 16) was induced in healthy volunteers by changing the O(2) concentration in inhaled air from 21% to 100%. RESULTS: The automatic software enhanced reproducibility, and the mean SD for repeated measurements was 3.7% for arterioles and 5.3% venules, in terms of percentage of SO(2) (five repeats, 10 individuals). The model derived for calibration was SO(2) = 125 - 142 . ODR. The arterial SO(2) measured 96% +/- 9% (mean +/- SD) during normoxia and 101% +/- 8% during hyperoxia (n = 16). The difference between normoxia and hyperoxia was significant (P = 0.0027, paired t-test). Corresponding numbers for venules were 55% +/- 14% and 78% +/- 15% (P < 0.0001). SO(2) is displayed as a pseudocolor map drawn on fundus images. CONCLUSIONS: The retinal oximeter is reliable, easy to use, and sensitive to changes in SO(2) when concentration of O(2) in inhaled air is changed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The impact of ocular blood flow in glaucoma
Flammer, J., Orgül, S., Costa, V. P., Orzalesi, N., Krieglstein, G. K., Serra, L. M., Renard, J.-P., & Stefánsson, E. (2002) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(02)00008-3 · Cited by 1,709
Yu, D.-Y., & Cringle, S. J. (2001) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(00)00027-6 · Cited by 653
Retinal Oxygen: Fundamental and Clinical Aspects
Wangsa-Wirawan, N. D. (2003) · Archives of Ophthalmology · doi:10.1001/archopht.121.4.547 · Cited by 546
Digital computer subroutine for the conversion of oxygen tension into saturation.
Kelman, G. R. (1966) · Journal of Applied Physiology · doi:10.1152/jappl.1966.21.4.1375 · Cited by 537
Metabolic dependence of photoreceptors on the choroid in the normal and detached retina.
Linsenmeier, R. A., & Padnick‐Silver, L. (2000) · PubMed · Cited by 322
Stefánsson, E. (2001) · Acta Ophthalmologica Scandinavica · doi:10.1034/j.1600-0420.2001.790502.x · Cited by 304
Oximetry of retinal vessels by dual-wavelength imaging: calibration and influence of pigmentation
Beach, J. M., Schwenzer, K. J., Srinivas, S., Kim, D., & Tiedeman, J. S. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.86.2.748 · Cited by 263
Self-citationVitrectomy prevents retinal hypoxia in branch retinal vein occlusion.
Stefánsson, E., Novack, R. L., & Hatchell, D. L. (1990) · PubMed · Cited by 233
Oxygen distribution in the macaque retina.
Ahmed, J., Braun, R. D., Dunn, R., & Linsenmeier, R. A. (1993) · PubMed · Cited by 220
Noninvasive technique for oximetry of blood in retinal vessels
Delori, F. C. (1988) · Applied Optics · doi:10.1364/ao.27.001113 · Cited by 207
Mervin, K., Valter, K., Maslim, J., Lewis, G., Fisher, S., & Stone, J. (1999) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(99)00104-x · Cited by 197
Supplemental Oxygen Improves Diabetic Macular Edema: A Pilot Study
Nguyen, Q. D., Shah, S. M., Van Anden, E., Sung, J. U., Vitale, S., & Campochiaro, P. A. (2004) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.03-0557 · Cited by 178
Retinal Oxygenation and Laser Treatment in Patients With Diabetic Retinopathy
Stefánsson, E., Machemer, R., de Juan, E., et al. (1992) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(14)75750-2 · Cited by 152
Diffusion of O2 in the retina of anesthetized miniature pigs in normoxia and hyperoxia
Pournaras, C. J., Riva, C. E., Tsacopoulos, M., et al. (1989) · Experimental Eye Research · doi:10.1016/0014-4835(89)90045-6 · Cited by 145
A Review of Methods for Human Retinal Oximetry
Harris, A., Dinn, R. B., Kagemann, L. E., et al. (2003) · Ophthalmic surgery, lasers & imaging retina · doi:10.3928/1542-8877-20030301-16 · Cited by 141
Self-citationPanretinal Photocoagulation and Retinal Oxygenation in Normal and Diabetic Cats
Stefánsson, E., Hatchell, D. L., Fisher, B. L., et al. (1986) · American Journal of Ophthalmology · doi:10.1016/0002-9394(86)90765-8 · Cited by 123
Lewis, G., Mervin, K., Valter, K., Maslim, J., Kappel, P. J., Stone, J., & Fisher, S. (1999) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(99)00103-8 · Cited by 114
Retinal oxygen consumption during hyperglycemia in patients with diabetes without retinopathy
Tiedeman, J. S., Kirk, S. E., Srinivas, S., et al. (1998) · Ophthalmology · doi:10.1016/s0161-6420(98)71029-1 · Cited by 109
Effects of hyperoxia on the oxygen distribution in the intact cat retina.
Linsenmeier, R. A., & Yancey, C. M. (1989) · PubMed · Cited by 96
Pournaras, C. J., Tsacopoulos, M., Strommer, K., Gilodi, N., & Leuenberger, P. (1990) · Ophthalmology · doi:10.1016/s0161-6420(90)32415-6 · Cited by 95
Hyperglycemia impairs retinal oxygen autoregulation in normal and diabetic dogs.
Ernest, J. T., Goldstick, T. K., & Engerman, R. L. (1983) · PubMed · Cited by 92
PO2 profiles and oxygen consumption in cat retina with an occluded retinal circulation.
Alder, V. A., Ben-nun, J., & Cringle, S. J. (1990) · PubMed · Cited by 87
Retinal oxygen distribution. Its role in the physiopathology of vasoproliferative microangiopathies.
Pournaras, C. J. (1995) · PubMed · Cited by 84
Subnormal retinal oxygenation response precedes diabetic-like retinopathy.
Berkowitz, B. A., Kowluru, R. A., Frank, R. N., et al. (1999) · PubMed · Cited by 78
Shonat, R. D., Wilson, D. F., Riva, C. E., & Cranstoun, S. D. (1992) · PubMed · Cited by 72
Retinal oxygen tension and the electroretinogram during arterial occlusion in the cat.
Braun, R. D., & Linsenmeier, R. A. (1995) · PubMed · Cited by 71
Pournaras, C. J., Tsacopoulos, M., Strommer, K., Gilodi, N., & Leuenberger, P. (1990) · Ophthalmology · doi:10.1016/s0161-6420(90)32414-4 · Cited by 71
Retinal oxygen saturation levels in patients with central retinal vein occlusion
Yoneya, S., Saito, T., Nishiyama, Y., et al. (2002) · Ophthalmology · doi:10.1016/s0161-6420(02)01109-0 · Cited by 63
Retinal oxygenation response and retinopathy
Trick, G. L., & Berkowitz, B. A. (2004) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2004.08.001 · Cited by 61
Effect of darkness on inner retinal hypoxia in diabetes
Drasdo, N., Chiti, Z., Owens, D. R., et al. (2002) · The Lancet · doi:10.1016/s0140-6736(02)09265-6 · Cited by 54
The ability of hyperoxia to limit the effects of experimental detachment in cone-dominated retina.
Sakai, T., Lewis, G. P., Linberg, K. A., & Fisher, S. K. (2001) · PubMed · Cited by 49
Optic nerve oxygen tension: effects of intraocular pressure and dorzolamide
la Cour, M. (2000) · British Journal of Ophthalmology · doi:10.1136/bjo.84.9.1045 · Cited by 49
The effect of photocoagulation on the oxygenation and ultrastructure of avascular retina
Novack, R. L., Stefánsson, E., & Hatchell, D. L. (1990) · Experimental Eye Research · doi:10.1016/0014-4835(90)90213-e · Cited by 46
The efficacy of delayed oxygen therapy in the treatment of experimental retinal detachment
Lewis, G. P., Talaga, K. C., Linberg, K. A., Avery, R. L., & Fisher, S. K. (2004) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2004.01.045 · Cited by 43
Laser-Induced Changes in Intraretinal Oxygen Distribution in Pigmented Rabbits
Yu, D., Cringle, S. J., Su, E., et al. (2005) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.04-0767 · Cited by 42
Retinal venous oxygen saturation and cardiac output during controlled hemorrhage and resuscitation
Denninghoff, K. R., Smith, M. H., Lompado, A., & Hillman, L. W. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01197.2001 · Cited by 40
Reflectance pulse oximetry measurements from the retinal fundus
de Kock, J. P., Tarassenko, L., Glynn, C. J., & Hill, A. R. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.238467 · Cited by 36
Pournaras, J.-A. C., Petropoulos, I. K., Munoz, J.-L., & Pournaras, C. J. (2004) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.04-0086 · Cited by 29
Berkowitz, B. A., Roberts, R. A., Luan, H., Peysakhov, J., Knoerzer, D. L., Connor, J. R., & Hohman, T. C. (2005) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.05-0132 · Cited by 24
A comparative study of the effects of argon and diode laser photocoagulation on retinal oxygenation
Funatsu, H., Wilson, C. A., Berkowitz, B. A., et al. (1997) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/bf00941724 · Cited by 24
Cited by
Sommermeyer, D., Hudecek, M., Kosasih, P. L., Gogishvili, T., Maloney, D. G., Turtle, C. J., & Riddell, S. R. (2016) · Leukemia · doi:10.1038/leu.2015.247 · Cited by 867
Optical coherence tomography today: speed, contrast, and multimodality
Drexler, W., Liu, M., Kumar, A., Kamali, T., Unterhuber, A., & Leitgeb, R. A. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.7.071412 · Cited by 473
Contemporary retinal imaging techniques in diabetic retinopathy: a review
Cole, E. D., Novais, E. A., Louzada, R. N., & Waheed, N. K. (2016) · Clinical & Experimental Ophthalmology · doi:10.1111/ceo.12711 · Cited by 91
Metadata
- Authors
- Hardarson, S. H., Harris, A., Karlsson, R. A., Halldorsson, G. H., Kagemann, L., Rechtman, E., Zoega, G. M., Eysteinsson, T., Benediktsson, J. A., Thorsteinsson, A., Jensen, P. K., Beach, J., & Stefa´nsson, E.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2006-11-01
- Volume
- 47
- Issue
- 11
- Pages
- 5011
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W2032401898
- Cited by
- 276
- References
- 40
- FWCI
- 4.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.