A Mechanical Model of the Cornea Considering the Crimping Morphology of Collagen Fibrils
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
PURPOSE: To develop a mechanical model with which to investigate the relationship between the crimping morphology of collagen fibrils and the nonlinear mechanical behavior of the cornea. METHODS: Uniaxial tensile experiments were performed with corneal strips to test their mechanical behavior. A constitutive model was constructed based on the Gaussian-distributed morphology of crimped collagen fibrils. The parameters that represent the micro characteristics of collagen fibrils were determined by fitting the experimental data to the constitutive model. Transmission electron microscopy (TEM) was used to visualize the crimping morphology of collagen fibrils in the stroma. A quantitative analysis of fibril crimping degrees in the TEM images was conducted to test the parameters predicted by the constitutive model. RESULTS: The parameters were derived using a fitting method that included the expectation for the distribution of fibril crimping degrees, μ = 1.063; the standard deviation, σ = 0.0781; the elastic modulus of collagen fibrils, E = 52.74 MPa; and the fibril ultimate strain, εb = 0.1957. TEM images showed a variation of the fibril crimping morphology when the cornea was subjected to different tensile loads. A good agreement was found between the parameters derived by the constitutive model and the data quantified from the TEM images. CONCLUSIONS: The nonlinear mechanical behavior of the cornea is closely correlated with the crimping morphology of collagen fibrils. The findings are expected to guide further research of corneal pathologies related to the abnormal microstructure of collagen fibrils.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The structure and transparency of the cornea
Maurice, D. M. (1957) · The Journal of Physiology · doi:10.1113/jphysiol.1957.sp005758 · Cited by 1,129
The specific architecture of the anterior stroma accounts for maintenance of corneal curvature
Muller, L. J. (2001) · British Journal of Ophthalmology · doi:10.1136/bjo.85.4.437 · Cited by 424
X-Ray Scattering Used to Map the Preferred Collagen Orientation in the Human Cornea and Limbus
Aghamohammadzadeh, H., Newton, R. H., & Meek, K. M. (2004) · Structure · doi:10.1016/j.str.2004.01.002 · Cited by 233
Abahussin, M., Hayes, S., Knox Cartwright, N. E., Kamma-Lorger, C. S., Khan, Y., Marshall, J., & Meek, K. M. (2009) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.09-3669 · Cited by 162
Meek, K. M., Blamires, T., Elliott, G. F., Gyi, T. J., & Nave, C. (1987) · Current Eye Research · doi:10.3109/02713688709034853 · Cited by 161
Constitutive modeling of crimped collagen fibrils in soft tissues
Grytz, R., & Meschke, G. (2009) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2008.12.009 · Cited by 160
Cited by
Corneal structure and transparency
Meek, K. M., & Knupp, C. (2015) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2015.07.001 · Cited by 853
“However, it has been postulated that this crimping plays an important role in the biomechanical response of the cornea (Liu et al., 2014).”
BackgroundPrint Me An Organ! Why We Are Not There Yet
Ng, W. L., Chua, C. K., & Shen, Y.-F. (2019) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2019.101145 · Cited by 287
Optical coherence elastography in ophthalmology
Kirby, M. A., Pelivanov, I., Song, S., Ambrozinski, Ł., Yoon, S. J., Gao, L., Li, D., Shen, T. T., Wang, R. K., & O’Donnell, M. (2017) · Journal of Biomedical Optics · doi:10.1117/1.jbo.22.12.121720 · Cited by 228
Self-citationTransverse depth-dependent changes in corneal collagen lamellar orientation and distribution
Abass, A., Hayes, S., White, N., Sorensen, T., & Meek, K. M. (2015) · Journal of The Royal Society Interface · doi:10.1098/rsif.2014.0717 · Cited by 78
“This may be of some significance as the mechanical behaviour of the cornea is closely correlated with its crimping morphology [29].”
BackgroundCrimp around the globe; patterns of collagen crimp across the corneoscleral shell
Jan, N.-J., Brazile, B. L., Hu, D., Grube, G., Wallace, J., Gogola, A., & Sigal, I. A. (2018) · Experimental Eye Research · doi:10.1016/j.exer.2018.04.003 · Cited by 47
“This may not be the only scale at which crimp exists in the eye, as Liu and colleagues reported crimp periods ∼2 μm, using transmitted electron microscopy (TEM)(Liu et al., 2014).”
Du, T., Niu, X., Hou, S., Li, Z., Li, P., & Fan, Y. (2019) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.36747 · Cited by 46
Self-citation
Metadata
- Authors
- Liu, X., Wang, L., Ji, J., Yao, W., Wei, W., Fan, J., Joshi, S., Li, D., & Fan, Y.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2014-04-28
- Volume
- 55
- Issue
- 4
- Pages
- 2739
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W2050910845
- Cited by
- 66
- References
- 6
- FWCI
- 2.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.