CoChat

The Post-Illumination Pupil Response (PIPR)

Open access
Adhikari, Prakash, Zele, Andrew J., Feigl, Beatrix · 2015 · Investigative Opthalmology & Visual Science
Cited by 173

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

PURPOSE: The post-illumination pupil response (PIPR) has been quantified using four metrics, but the spectral sensitivity of only one is known; here we determine the other three. To optimize the human PIPR measurement, we determine the protocol producing the largest PIPR, the duration of the PIPR, and the metric(s) with the lowest coefficient of variation. METHODS: The consensual pupil light reflex (PLR) was measured with a Maxwellian view pupillometer. Experiment 1: Spectral sensitivity of four PIPR metrics (plateau, 6 seconds, area under curve early and late recovery) was determined from a criterion PIPR to a 1-second pulse and fitted with vitamin A1 nomogram (λ(max) = 482 nm). Experiment 2: The PLR was measured as a function of three stimulus durations (1 second, 10 seconds, 30 seconds), five irradiances spanning low to high melanopsin excitation levels (retinal irradiance: 9.8-14.8 log quanta.cm(-2).s(-1)), and two wavelengths, one with high (465 nm) and one with low (637 nm) melanopsin excitation. Intra- and interindividual coefficients of variation (CV) were calculated. RESULTS: The melanopsin (opn4) photopigment nomogram adequately describes the spectral sensitivity of all four PIPR metrics. The PIPR amplitude was largest with 1-second short-wavelength pulses (≥ 12.8 log quanta.cm(-2).s(-1)). The plateau and 6-second PIPR showed the least intra- and interindividual CV (≤ 0.2). The maximum duration of the sustained PIPR was 83.0 ± 48.0 seconds (mean ± SD) for 1-second pulses and 180.1 ± 106.2 seconds for 30-second pulses (465 nm; 14.8 log quanta.cm(-2).s(-1)). CONCLUSIONS: All current PIPR metrics provide a direct measure of the intrinsic melanopsin photoresponse. To measure progressive changes in melanopsin function in disease, we recommend that the PIPR be measured using short-duration pulses (e.g., ≤ 1 second) with high melanopsin excitation and analyzed with plateau and/or 6-second metrics. Our PIPR duration data provide a baseline for the selection of interstimulus intervals between consecutive pupil testing sequences.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.14-16233

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 173

Metadata

Authors
Adhikari, P., Zele, A. J., & Feigl, B.
Venue
Investigative Opthalmology & Visual Science
Published
2015-06-11
Volume
56
Issue
6
Pages
3838
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W571073904
Cited by
173
References
5
FWCI
6.99
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Post-Illumination Pupil Response (PIPR). https://app.cochat.ai/papers/10.1167/iovs.14-16233
The paper
Adhikari, P., Zele, A. J., & Feigl, B. (2015). The Post-Illumination Pupil Response (PIPR). Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.14-16233

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.