Applications of Raman Spectroscopy in Biopharmaceutical Manufacturing: A Short Review
Open accessThe DOI matches its Crossref record; 170 of the 170 references it cites were found in a registry or an index.
Abstract
The production of active pharmaceutical ingredients (APIs) is currently undergoing its biggest transformation in a century. The changes are based on the rapid and dramatic introduction of protein- and macromolecule-based drugs (collectively known as biopharmaceuticals) and can be traced back to the huge investment in biomedical science (in particular in genomics and proteomics) that has been ongoing since the 1970s. Biopharmaceuticals (or biologics) are manufactured using biological-expression systems (such as mammalian, bacterial, insect cells, etc.) and have spawned a large (>€35 billion sales annually in Europe) and growing biopharmaceutical industry (BioPharma). The structural and chemical complexity of biologics, combined with the intricacy of cell-based manufacturing, imposes a huge analytical burden to correctly characterize and quantify both processes (upstream) and products (downstream). In small molecule manufacturing, advances in analytical and computational methods have been extensively exploited to generate process analytical technologies (PAT) that are now used for routine process control, leading to more efficient processes and safer medicines. In the analytical domain, biologic manufacturing is considerably behind and there is both a huge scope and need to produce relevant PAT tools with which to better control processes, and better characterize product macromolecules. Raman spectroscopy, a vibrational spectroscopy with a number of useful properties (nondestructive, non-contact, robustness) has significant potential advantages in BioPharma. Key among them are intrinsically high molecular specificity, the ability to measure in water, the requirement for minimal (or no) sample pre-treatment, the flexibility of sampling configurations, and suitability for automation. Here, we review and discuss a representative selection of the more important Raman applications in BioPharma (with particular emphasis on mammalian cell culture). The review shows that the properties of Raman have been successfully exploited to deliver unique and useful analytical solutions, particularly for online process monitoring. However, it also shows that its inherent susceptibility to fluorescence interference and the weakness of the Raman effect mean that it can never be a panacea. In particular, Raman-based methods are intrinsically limited by the chemical complexity and wide analyte-concentration-profiles of cell culture media/bioprocessing broths which limit their use for quantitative analysis. Nevertheless, with appropriate foreknowledge of these limitations and good experimental design, robust analytical methods can be produced. In addition, new technological developments such as time-resolved detectors, advanced lasers, and plasmonics offer potential of new Raman-based methods to resolve existing limitations and/or provide new analytical insights.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Fluorescence Spectroscopy
Lakowicz, J. R. (1999) · Springer eBooks · doi:10.1007/978-1-4757-3061-6 · Cited by 26,947
Principles of Fluorescence Spectroscopy
(2006) · Springer eBooks · doi:10.1007/978-0-387-46312-4 · Cited by 19,339
Encyclopedia of Analytical Chemistry: Applications, Theory and Instrumentation
(2006) · Wiley eBooks · doi:10.1002/9780470027318 · Cited by 7,403
Partial least-squares regression: a tutorial
Geladi, P., & Kowalski, B. R. (1986) · Analytica Chimica Acta · doi:10.1016/0003-2670(86)80028-9 · Cited by 6,992 · cited 1×
“The most widely used regression based method for quantitative analysis of Raman data is partial least squares (PLS) 99,100,122–124 and derivatives thereof.”
Molecular Fluorescence: Principles and Applications
Valeur, B., & Berberan‐Santos, M. N. (2012) · Wiley eBooks · doi:10.1002/9783527650002 · Cited by 4,098
Haaland, D. M., & Thomas, E. V. (1988) · Analytical Chemistry · doi:10.1021/ac00162a020 · Cited by 2,539
SERS: Materials, applications, and the future
Sharma, B., Frontiera, R. R., Henry, A.-I., Ringe, E., & Van Duyne, R. P. (2012) · Materials Today · doi:10.1016/s1369-7021(12)70017-2 · Cited by 2,454 · cited 1×
“71 SERS enhancement has the added advantage of effectively ‘‘quenching’’ analyte molecule fluorescence because it increases the Raman signal to a much greater degree than it does the fluorescence signal.”
Steele, D. (1990) · Spectrochimica Acta Part A: Molecular Spectroscopy · doi:10.1016/0584-8539(90)80069-b · Cited by 2,240
Principles of Surface-Enhanced Raman Spectroscopy: and Related Plasmonic Effects
Ru, E. C. L., & Etchegoin, P. (2008) · Cited by 1,455
A review of near infrared spectroscopy and chemometrics in pharmaceutical technologies
Roggo, Y., Chalus, P., Maurer, L., Lema-Martinez, C., Edmond, A., & Jent, N. (2007) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2007.03.023 · Cited by 1,131 · cited 1×
“45,46 ,”
Cited by
Time-gated Raman spectroscopy – a review
Kögler, M., & Heilala, B. (2020) · Measurement Science and Technology · doi:10.1088/1361-6501/abb044 · Cited by 107
Raman Spectroscopy and Its Modifications Applied to Biological and Medical Research
Allakhverdiev, E. S., Khabatova, V. V., Kossalbayev, B. D., Zadneprovskaya, E. V., Rodnenkov, O. V., Martynyuk, T. V., Maksimov, G. V., Alwasel, S., Tomo, T., & Allakhverdiev, S. I. (2022) · Cells · doi:10.3390/cells11030386 · Cited by 88
Tulsyan, A., Schorner, G., Khodabandehlou, H., Wang, T., Coufal, M., & Undey, C. (2019) · Biotechnology and Bioengineering · doi:10.1002/bit.27100 · Cited by 82
Kornecki, M., & Strube, J. (2018) · Bioengineering · doi:10.3390/bioengineering5010025 · Cited by 61
“Methods are available that can acquire spectra and integrate them into PLS models, resulting in the online determination of viable cell, substrate, and metabolite concentrations [46,47].”
BackgroundRecent application of spectroscopy for the detection of microalgae life information: A review
Liu, J.-Y., Zeng, L.-H., & Ren, Z.-H. (2020) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2018.1509345 · Cited by 59
Feidl, F., Garbellini, S., Vogg, S., Sokolov, M., Souquet, J., Broly, H., Butté, A., & Morbidelli, M. (2019) · Biotechnology Progress · doi:10.1002/btpr.2847 · Cited by 59
Liu, Y., Zhang, C., Chen, J., Fernandez, J., Vellala, P., Kulkarni, T. A., Aguilar, I., Ritz, D., Lan, K., Patel, P., et al. (2022) · Journal of Pharmaceutical Sciences · doi:10.1016/j.xphs.2021.09.011 · Cited by 57
Helgers, H., Schmidt, A., Lohmann, L. J., Vetter, F. L., Juckers, A., Jensch, C., Mouellef, M., Zobel-Roos, S., & Strube, J. (2021) · Processes · doi:10.3390/pr9010172 · Cited by 52
Goldrick, S., Umprecht, A., Tang, A., Zakrzewski, R., Cheeks, M., Turner, R., Charles, A., Les, K., Hulley, M., Spencer, C., et al. (2020) · Processes · doi:10.3390/pr8091179 · Cited by 48
“Different types of Raman Spectroscopy, including Resonance Raman Spectroscopy, Raman Optical Activity, and surface-enhanced Raman spectroscopy (SERS), as well as their applications, are extensively described in a review by Buckley and Ryder [13].”
Feidl, F., Garbellini, S., Luna, M. F., Vogg, S., Souquet, J., Broly, H., Morbidelli, M., & Butté, A. (2019) · Processes · doi:10.3390/pr7100683 · Cited by 46
Rolinger, L., Rüdt, M., & Hubbuch, J. (2021) · Biotechnology and Bioengineering · doi:10.1002/bit.27894 · Cited by 33
Cell culture media analysis using rapid spectroscopic methods
Ryder, A. G. (2018) · Current Opinion in Chemical Engineering · doi:10.1016/j.coche.2018.08.008 · Cited by 30
“Liquid formulations, less useful: Good only for > millimolar concentrations, not always possible at that level for complex mixtures [37].”
BackgroundInfluentialSelf-citationNitika, N., Keerthiveena, B., Thakur, G., & Rathore, A. S. (2024) · Pharmaceutical Research · doi:10.1007/s11095-024-03663-9 · Cited by 26
“…spectra have minimal interference from water absorption bands, which otherwise mask spectroscopic signals of component molecules in aqueous solutions, a common problem in deploying spectroscopic approaches in biopharma-ceutical manufacturing compared to solid-state pharmaceutical processes [17].”
Improving Biopharmaceutical Safety Through Verification‐Based Quality Control
Yu, Y. B., Taraban, M. B., Wang, W., & Briggs, K. T. (2017) · Trends in Biotechnology · doi:10.1016/j.tibtech.2017.08.010 · Cited by 23
Multi‐Dimensional Technology—Recent Advances and Applications for Biotherapeutic Characterization
Bouvarel, T., Camperi, J., & Guillarme, D. (2024) · Journal of Separation Science · doi:10.1002/jssc.202300928 · Cited by 20
Metadata
- Authors
- Buckley, K., & Ryder, A. G.
- Venue
- Applied Spectroscopy
- Publisher
- SAGE Publications
- Published
- 2017-05-23
- Volume
- 71
- Issue
- 6
- Pages
- 1085-1116
- ISSN
- 0003-7028 (ISSN-L)
- 1943-3530
- OpenAlex
- W2618036898
- Cited by
- 160
- References
- 170
- FWCI
- 8.39
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.