Applications of Raman Spectroscopy in Biopharmaceutical Manufacturing: A Short Review
Open accessThe DOI matches its Crossref record; 170 of the 170 references it cites were found in a registry or an index.
Abstract
The production of active pharmaceutical ingredients (APIs) is currently undergoing its biggest transformation in a century. The changes are based on the rapid and dramatic introduction of protein- and macromolecule-based drugs (collectively known as biopharmaceuticals) and can be traced back to the huge investment in biomedical science (in particular in genomics and proteomics) that has been ongoing since the 1970s. Biopharmaceuticals (or biologics) are manufactured using biological-expression systems (such as mammalian, bacterial, insect cells, etc.) and have spawned a large (>€35 billion sales annually in Europe) and growing biopharmaceutical industry (BioPharma). The structural and chemical complexity of biologics, combined with the intricacy of cell-based manufacturing, imposes a huge analytical burden to correctly characterize and quantify both processes (upstream) and products (downstream). In small molecule manufacturing, advances in analytical and computational methods have been extensively exploited to generate process analytical technologies (PAT) that are now used for routine process control, leading to more efficient processes and safer medicines. In the analytical domain, biologic manufacturing is considerably behind and there is both a huge scope and need to produce relevant PAT tools with which to better control processes, and better characterize product macromolecules. Raman spectroscopy, a vibrational spectroscopy with a number of useful properties (nondestructive, non-contact, robustness) has significant potential advantages in BioPharma. Key among them are intrinsically high molecular specificity, the ability to measure in water, the requirement for minimal (or no) sample pre-treatment, the flexibility of sampling configurations, and suitability for automation. Here, we review and discuss a representative selection of the more important Raman applications in BioPharma (with particular emphasis on mammalian cell culture). The review shows that the properties of Raman have been successfully exploited to deliver unique and useful analytical solutions, particularly for online process monitoring. However, it also shows that its inherent susceptibility to fluorescence interference and the weakness of the Raman effect mean that it can never be a panacea. In particular, Raman-based methods are intrinsically limited by the chemical complexity and wide analyte-concentration-profiles of cell culture media/bioprocessing broths which limit their use for quantitative analysis. Nevertheless, with appropriate foreknowledge of these limitations and good experimental design, robust analytical methods can be produced. In addition, new technological developments such as time-resolved detectors, advanced lasers, and plasmonics offer potential of new Raman-based methods to resolve existing limitations and/or provide new analytical insights.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Fluorescence Spectroscopy
Lakowicz, J. R. (1999) · Springer eBooks · doi:10.1007/978-1-4757-3061-6 · Cited by 26,947
Principles of Fluorescence Spectroscopy
(2006) · Springer eBooks · doi:10.1007/978-0-387-46312-4 · Cited by 19,339
Encyclopedia of Analytical Chemistry: Applications, Theory and Instrumentation
(2006) · Wiley eBooks · doi:10.1002/9780470027318 · Cited by 7,403
Partial least-squares regression: a tutorial
Geladi, P., & Kowalski, B. R. (1986) · Analytica Chimica Acta · doi:10.1016/0003-2670(86)80028-9 · Cited by 6,992 · cited 1×
“The most widely used regression based method for quantitative analysis of Raman data is partial least squares (PLS) 99,100,122–124 and derivatives thereof.”
Molecular Fluorescence: Principles and Applications
Valeur, B., & Berberan‐Santos, M. N. (2012) · Wiley eBooks · doi:10.1002/9783527650002 · Cited by 4,098
Haaland, D. M., & Thomas, E. V. (1988) · Analytical Chemistry · doi:10.1021/ac00162a020 · Cited by 2,539
SERS: Materials, applications, and the future
Sharma, B., Frontiera, R. R., Henry, A.-I., Ringe, E., & Van Duyne, R. P. (2012) · Materials Today · doi:10.1016/s1369-7021(12)70017-2 · Cited by 2,454 · cited 1×
“71 SERS enhancement has the added advantage of effectively ‘‘quenching’’ analyte molecule fluorescence because it increases the Raman signal to a much greater degree than it does the fluorescence signal.”
Steele, D. (1990) · Spectrochimica Acta Part A: Molecular Spectroscopy · doi:10.1016/0584-8539(90)80069-b · Cited by 2,240
Principles of Surface-Enhanced Raman Spectroscopy: and Related Plasmonic Effects
Ru, E. C. L., & Etchegoin, P. (2008) · Cited by 1,455
A review of near infrared spectroscopy and chemometrics in pharmaceutical technologies
Roggo, Y., Chalus, P., Maurer, L., Lema-Martinez, C., Edmond, A., & Jent, N. (2007) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2007.03.023 · Cited by 1,131 · cited 1×
“45,46 ,”
Raman spectroscopy of proteins: a review
Rygula, A., Majzner, K., Marzec, K. M., Kaczor, A., Pilarczyk, M., & Baranska, M. (2013) · Journal of Raman Spectroscopy · doi:10.1002/jrs.4335 · Cited by 1,124 · cited 1×
“CRS and resonance Raman can be used to easily discriminate different proteins, 174 on the basis of molecular structure and the technique can be implemented on both solid-state and solution samples.”
Modern Raman spectroscopy: a practical approach
(2005) · Choice Reviews Online · doi:10.5860/choice.43-0956 · Cited by 1,113 · cited 2×
“Resonance Raman spectroscopy involves purposely selecting excitation photons whose energy are similar to the energy gap between the electronic orbitals of a specific target molecule.(74) By designing the system in this way, one creates a resonance effect and increases the probability that the photon will inelastically…”
ROBPCA: A New Approach to Robust Principal Component Analysis
Hubert, M., Rousseeuw, P. J., & Vanden Branden, K. (2005) · Technometrics · doi:10.1198/004017004000000563 · Cited by 1,052 · cited 1×
“Spectral variance analysis: The objective here is to assess the spectral variance using principal component analysis (PCA) or robust PCA (ROBPCA), 108,109 in order to understand the factors that influence the appearance of the spectra.”
Protein aggregation: Pathways, induction factors and analysis
Mahler, H.-C., Friess, W., Grauschopf, U., & Kiese, S. (2009) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.21566 · Cited by 901
Quality by design for biopharmaceuticals
Rathore, A. S., & Winkle, H. (2009) · Nature Biotechnology · doi:10.1038/nbt0109-26 · Cited by 830 · cited 1×
“If faster, easier compositional analysis could be carried out, then media quality could be better controlled and more efficient, and consistent manufacturing processes would result.(5,6,136,137)”
Protein aggregation—Pathways and influencing factors
Wang, W., Nema, S., & Teagarden, D. (2010) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2010.02.025 · Cited by 806
Variable selection in regression—a tutorial
Andersen, C. M., & Bro, R. (2010) · Journal of Chemometrics · doi:10.1002/cem.1360 · Cited by 697 · cited 1×
“As with all other aspects of chemometrics, there are many different algorithms that can be used for variable selection, 112–115 in our group ant colony optimization (ACO) 116–118 has been used most often.”
McNay, G., Eustace, D., Smith, W. E., Faulds, K., & Graham, D. (2011) · Applied Spectroscopy · doi:10.1366/11-06365 · Cited by 655
Multivariate Curve Resolution (MCR) from 2000: Progress in Concepts and Applications
de Juan, A., & Tauler, R. (2006) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408340600970005 · Cited by 636 · cited 1×
“Spectral deconvolution: This involves following any identified changes in molecular composition using curve resolution methods such as multivariate curve resolution (MCR) 103,119,120 and/or parallel factor analysis (PARAFAC).”
Design of therapeutic proteins with enhanced stability
Chennamsetty, N., Voynov, V., Kayser, V., Helk, B., & Trout, B. L. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0904191106 · Cited by 598
Subsurface Probing in Diffusely Scattering Media Using Spatially Offset Raman Spectroscopy
Matousek, P., Clark, I. P., Draper, E. R. C., Morris, M. D., Goodship, A. E., Everall, N., Towrie, M., Finney, W. F., & Parker, A. W. (2005) · Applied Spectroscopy · doi:10.1366/0003702053641450 · Cited by 548
Quality by Design in Biopharmaceuticals
Yang, H. (2016) · doi:10.1201/9781315371726-7 · Cited by 543
Mammalian cell protein expression for biopharmaceutical production
Zhu, J. (2012) · Biotechnology Advances · doi:10.1016/j.biotechadv.2011.08.022 · Cited by 491 · cited 2×
“in biomedical research to produce new biologics.(1,2) In the decades since, this research has borne fruit and the BioPharma sector has become a behemoth that has produced ‘‘blockbuster’’ drugs with multi-billion-euro sales, e.”
Handbook of raman spectroscopy from the research laboratory to the process line
Lewis, I. R., & Edwards, H. G. M. (2001) · Cited by 468
Infrared and raman spectroscopy: Methods and applications
(1996) · Journal of Molecular Structure · doi:10.1016/0022-2860(96)88418-3 · Cited by 466
Raman spectroscopy of proteins: from peptides to large assemblies
Tuma, R. (2005) · Journal of Raman Spectroscopy · doi:10.1002/jrs.1323 · Cited by 460 · cited 3×
“, the cysteine sulfhydryl group, SH, gives rise to a band in the 2500–2600 cm 1 region), the nature of the molecule’s hydrogen-bonding (ratio of the tyrosine bands at 830 cm 1 and 850 cm (1)), and the degree of methionine oxidation (bands at 704 cm 1 and 1010 cm (1)).(129) In one 2007 study, workers from Amgen Inc.”
Applications of Raman spectroscopy in pharmaceutical analysis
Vankeirsbilck, T., Vercauteren, A., Baeyens, W., Van der Weken, G., Verpoort, F., Vergote, G., & Remon, J. P. (2002) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(02)01208-6 · Cited by 439 · cited 4×
“207 In two recent solid-state analysis studies we collected nearly 1 million spectra, 211 and (cid:2) 9 million Raman spectra (as yet unpublished results) in experiments over a timeframe of three to six months.”
InfluentialQuantitative Analysis Using Raman Spectrometry
Pelletier, M. J. (2003) · Applied Spectroscopy · doi:10.1366/000370203321165133 · Cited by 435 · cited 1×
“CRS is a mature and widely adopted technique that is particularly suited to being integrated into the manufacturing systems that require real-time quantitative and qualitative chemical information.(57) As noted above, only a very small fraction of scattering events results in the creation of a Raman scattered photon a…”
Chemometrics in Analytical Spectroscopy
Adams, M. J. (2004) · Royal Society of Chemistry eBooks · doi:10.1039/9781847550484 · Cited by 423
Roadmap for implementation of quality by design (QbD) for biotechnology products
Rathore, A. S. (2009) · Trends in Biotechnology · doi:10.1016/j.tibtech.2009.06.006 · Cited by 411 · cited 1×
“These regulatory demands have led to the adoption of smarter process-management systems (such as Quality by Design [QbD] 4 and process analytical technology [PAT] 5,6 ) and to increased need for new/novel analytical technologies.”
Process analytical technology (PAT) for biopharmaceutical products
Rathore, A. S., Bhambure, R., & Ghare, V. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3781-x · Cited by 368 · cited 1×
“If faster, easier compositional analysis could be carried out, then media quality could be better controlled and more efficient, and consistent manufacturing processes would result.(5,6,136,137)”
Clark, R. J. H., & Dines, T. J. (1986) · Angewandte Chemie International Edition in English · doi:10.1002/anie.198601311 · Cited by 363
Chemometrics in spectroscopy. Part 1. Classical chemometrics
Geladi, P. (2003) · Spectrochimica Acta Part B: Atomic Spectroscopy · doi:10.1016/s0584-8547(03)00037-5 · Cited by 343 · cited 8×
“The most widely used regression based method for quantitative analysis of Raman data is partial least squares (PLS) 99,100,122–124 and derivatives thereof.”
InfluentialEsmonde-White, K. A., Cuellar, M., Uerpmann, C., Lenain, B., & Lewis, I. R. (2017) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-016-9824-1 · Cited by 332 · cited 1×
“Inline monitoring has shown utility for collecting continuous and instantaneous data (when compared to the long duration of a typical mammalian cell culture, ten or more days), and both forms of bioprocesses monitoring have demonstrated that they can provide useful information on the scale-up of fed-batch processes (t…”
Haaland, D. M., & Thomas, E. V. (1988) · Analytical Chemistry · doi:10.1021/ac00162a021 · Cited by 332 · cited 1×
“The most widely used regression based method for quantitative analysis of Raman data is partial least squares (PLS) 99,100,122–124 and derivatives thereof.”
Robust statistics in data analysis — A review
Daszykowski, M., Kaczmarek, K., Vander Heyden, Y., & Walczak, B. (2007) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2006.06.016 · Cited by 331
Abu‐Absi, N. R., Kenty, B. M., Cuellar, M. E., Borys, M. C., Sakhamuri, S., Strachan, D. J., Hausladen, M. C., & Li, Z. J. (2011) · Biotechnology and Bioengineering · doi:10.1002/bit.23023 · Cited by 322
Pharmaceutical applications of Mid-IR and Raman spectroscopy
Wartewig, S., & Neubert, R. H. H. (2005) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2005.01.022 · Cited by 316 · cited 2×
“The two classes of optical spectroscopy that have most relevance to the BioPharma field are the electronic and vibrational spectroscopies.(22) These offer many advantages over other analytical techniques in that samples can be probed without destruction/contact, the systems often have lower instrumentation/capital cos…”
Fluorescence correlation spectroscopy
Ries, J., & Schwille, P. (2012) · BioEssays · doi:10.1002/bies.201100111 · Cited by 315
Shreve, A. P., Cherepy, N. J., & Mathies, R. A. (1992) · Applied Spectroscopy · doi:10.1366/0003702924125122 · Cited by 312 · cited 1×
“…the other methods for dealing with fluorescence, such as modulated Raman spectroscopy, 65 shifted excitation Raman difference spectroscopy (SERDS), 66 and subtracted shifted Raman spectroscopy (SSRS), 67 are intrinsically limited by the fact that fluorescence and Raman photons are measured…”
Chi, Z., Chen, X. G., Holtz, J. S. W., & Asher, S. A. (1998) · Biochemistry · doi:10.1021/bi971160z · Cited by 301 · cited 2×
“81,96,97 These Raman-based approaches have clear advantages compared to other analytical methods such as Fourier IR, X-Ray crystallography, or NMR ( e.g. protein structural analysis can be carried out both in the solid-state and in solution using Raman spectroscopy).”
Achievements in resonance Raman spectroscopy
Efremov, E. V., Ariese, F., & Gooijer, C. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.11.006 · Cited by 289 · cited 2×
“77 RRS can be also be performed on nanostructured metal surfaces (giving a combined RRS/SERS enhancement [SERRS] 78 or with higher-energy UV photons in a technique known as UV resonance Raman spectroscopy [UVRRS].”
Torii, H., & Tasumi, M. (1998) · Journal of Raman Spectroscopy · doi:10.1002/(sici)1097-4555(199801)29:1<7::aid-jrs215>3.0.co;2-v · Cited by 276
Raman spectroscopy of protein pharmaceuticals
Wen, Z. (2007) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.20895 · Cited by 262 · cited 2×
“Raman spectroscopy enabled elucidation of the fibrillation mechanism and revealed chemical/structural information that would have been difficult to obtain with any other technique.(130,189) In 2013, the Goodacre group used 2D correlation analysis of CRS data (780 nm excitation) to probe the stability of 1106 Applied S…”
Azzouz, T., & Tauler, R. (2008) · Talanta · doi:10.1016/j.talanta.2007.08.024 · Cited by 254 · cited 1×
“Spectral deconvolution: This involves following any identified changes in molecular composition using curve resolution methods such as multivariate curve resolution (MCR) 103,119,120 and/or parallel factor analysis (PARAFAC).”
Garrido, M., Rius, F. X., & Larrechi, M. S. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-1955-6 · Cited by 250 · cited 2×
“Spectral deconvolution: This involves following any identified changes in molecular composition using curve resolution methods such as multivariate curve resolution (MCR) 103,119,120 and/or parallel factor analysis (PARAFAC).”
UV Resonance Raman excitation profiles of the aromatic amino acids
Asher, S. A., Ludwig, M., & Johnson, C. R. (1986) · Journal of the American Chemical Society · doi:10.1021/ja00272a005 · Cited by 240
Read, E. K., Park, J. T., Shah, R. B., Riley, B. S., Brorson, K. A., & Rathore, A. S. (2010) · Biotechnology and Bioengineering · doi:10.1002/bit.22528 · Cited by 217 · cited 2×
“5”
UV Resonance Raman Investigations of Peptide and Protein Structure and Dynamics
Oladepo, S. A., Xiong, K., Hong, Z., Asher, S. A., Handen, J., & Lednev, I. K. (2012) · Chemical Reviews · doi:10.1021/cr200198a · Cited by 214 · cited 2×
“176 In 2012, the utility of UVRRS as a tool for fast biopharmaceutical characterization of proteins was investigated and the secondary structure of the salmon calcitonin (sCT) protein was probed.”
Validation of three viable-cell counting methods: Manual, semi-automated, and automated
Cadena-Herrera, D., Esparza-De Lara, J. E., Ramírez-Ibañez, N. D., López-Morales, C. A., Pérez, N. O., Flores-Ortiz, L. F., & Medina-Rivero, E. (2015) · Biotechnology Reports · doi:10.1016/j.btre.2015.04.004 · Cited by 211 · cited 9×
“PLS calibration models were successfully developed for all analytes (but not VCD) and the models were transferred to the 15 L scale.”
InfluentialRead, E. K., Shah, R. B., Riley, B. S., Park, J. T., Brorson, K. A., & Rathore, A. S. (2010) · Biotechnology and Bioengineering · doi:10.1002/bit.22529 · Cited by 202 · cited 1×
“These regulatory demands have led to the adoption of smarter process-management systems (such as Quality by Design [QbD] 4 and process analytical technology [PAT] 5,6 ) and to increased need for new/novel analytical technologies.”
Coupling ultra-high-pressure liquid chromatography with mass spectrometry
Guillarme, D., Schappler, J., Rudaz, S., & Veuthey, J.-L. (2010) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2009.09.008 · Cited by 201
Chang, L. (., Shepherd, D., Sun, J., Tang, X. (., & Pikal, M. J. (2005) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.20363 · Cited by 199 · cited 1×
“22 42 NIR absorption spectroscopy is a near analogue that utilizes shorter-wavelength/higher-energy light (800–2500nm).”
Advances in on-line monitoring and control of mammalian cell cultures: Supporting the PAT initiative
Teixeira, A. P., Oliveira, R., Alves, P. M., & Carrondo, M. J. T. (2009) · Biotechnology Advances · doi:10.1016/j.biotechadv.2009.05.003 · Cited by 193
De Beer, T. R. M., Vercruysse, P., Burggraeve, A., Quinten, T., Ouyang, J., Zhang, X., Vervaet, C., Remon, J. P., & Baeyens, W. R. G. (2009) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.21633 · Cited by 190
Robust PCA and classification in biosciences
Hubert, M., & Engelen, S. (2004) · Bioinformatics · doi:10.1093/bioinformatics/bth158 · Cited by 186 · cited 1×
“Spectral variance analysis: The objective here is to assess the spectral variance using principal component analysis (PCA) or robust PCA (ROBPCA), 108,109 in order to understand the factors that influence the appearance of the spectra.”
Eliasson, C., & Matousek, P. (2007) · Analytical Chemistry · doi:10.1021/ac062223z · Cited by 186
Intact protein analysis in the biopharmaceutical field
Staub, A., Guillarme, D., Schappler, J., Veuthey, J.-L., & Rudaz, S. (2011) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2011.01.031 · Cited by 180
Purifying biopharmaceuticals: knowledge-based chromatographic process development
Hanke, A. T., & Ottens, M. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.02.001 · Cited by 176
Cervera, A. E., Petersen, N., Lantz, A. E., Larsen, A., & Gernaey, K. V. (2009) · Biotechnology Progress · doi:10.1002/btpr.280 · Cited by 175 · cited 1×
“47 First, the wavelength range allows for the use of simple light sources (e.g., tungsten lamps) and relatively inexpensive glass-based optical components, fibers, and sampling systems.”
Enzymatic hydrolysis of soy proteins and the hydrolysates utilisation
Sun, X. (2011) · International Journal of Food Science & Technology · doi:10.1111/j.1365-2621.2011.02785.x · Cited by 174
Mikhonin, A. V., Bykov, S. V., Myshakina, N. S., & Asher, S. A. (2006) · The Journal of Physical Chemistry B · doi:10.1021/jp054593h · Cited by 174
Craven, S., Whelan, J., & Glennon, B. (2014) · Journal of Process Control · doi:10.1016/j.jprocont.2014.02.007 · Cited by 171 · cited 3×
“demonstrated the next logical step, a Raman analysis that could be used to control a bioprocess; the ‘‘nonlinear model predictive controller’’ (NMPC) used online Raman measurements and a closed-loop feedback control system to maintain the glucose concentration at 11 mM inside a CHO bioprocess (15 L) bioreactor (Figure…”
Whelan, J., Craven, S., & Glennon, B. (2012) · Biotechnology Progress · doi:10.1002/btpr.1590 · Cited by 159 · cited 5×
“PLS calibration models were successfully developed for all analytes (but not VCD) and the models were transferred to the 15 L scale.(56) It can be safely said that this type of routine process monitoring is now well established.”
InfluentialPhotosensitized Amino Acid Degradation in the Presence of Riboflavin and Its Derivatives
Remucal, C. K., & McNeill, K. (2011) · Environmental Science & Technology · doi:10.1021/es200411a · Cited by 159 · cited 1×
“Stability testing is also important, as media are susceptible to a variety of chemical and biological degradation pathways that can adversely affect their performance, for example, riboflavin containing media are photosensitive and the breakdown products are cytotoxic.(34,133,134) If the testing enables the identifica…”
Sutter, J. M., & Kalivas, J. H. (1993) · Microchemical Journal · doi:10.1006/mchj.1993.1012 · Cited by 158 · cited 1×
“As with all other aspects of chemometrics, there are many different algorithms that can be used for variable selection, 112–115 in our group ant colony optimization (ACO) 116–118 has been used most often.”
Rodriguez-Aller, M., Gurny, R., Veuthey, J.-L., & Guillarme, D. (2013) · Journal of Chromatography A · doi:10.1016/j.chroma.2012.09.061 · Cited by 158
Stoien, J. D., & Wang, R. J. (1974) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.71.10.3961 · Cited by 156
Bronsema, K. J., Bischoff, R., & van de Merbel, N. C. (2012) · Journal of Chromatography B · doi:10.1016/j.jchromb.2012.02.021 · Cited by 155 · cited 1×
“Again, these combined MS/chromatography technologies are widely adopted and are the subject of much scientific literature (e.g., HPLC-MS, 15,16 UHPLC-MS, 17,18 CE-MS 19,20 ).”
Larkin, P. J., Dabros, M., Sarsfield, B. A., Chan, E. J., Carriere, J. T. A., & Smith, B. C. (2014) · Applied Spectroscopy · doi:10.1366/13-07329 · Cited by 153 · cited 1×
“199 This spectral region is useful for probing solid-state properties (such as polymorphism) and or analyzing protein stability.”
Optical sensor systems for bioprocess monitoring
Ulber, R., Frerichs, J.-G., & Beutel, S. (2003) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-003-1930-1 · Cited by 151
In‐situ near infrared spectroscopy to monitor key analytes in mammalian cell cultivation
Arnold, S. A., Crowley, J., Woods, N., Harvey, L. M., & McNeil, B. (2003) · Biotechnology and Bioengineering · doi:10.1002/bit.10738 · Cited by 149
UV resonance Raman spectroscopy for analytical, physical, and biophysical chemistry. Part 2
Asher, S. A. (1993) · Analytical Chemistry · doi:10.1021/ac00052a001 · Cited by 146
Berry, B., Moretto, J., Matthews, T., Smelko, J., & Wiltberger, K. (2015) · Biotechnology Progress · doi:10.1002/btpr.2035 · Cited by 142 · cited 2×
“163 Shortly after this, a group from Pfizer reported on the use of Raman for the in-line measurement of glucose, lactate, and VCD in a fed-batch mammalian (CHO) cell culture process.”
Raman Spectroscopy-Based Sensitive and Specific Detection of Glycated Hemoglobin
Barman, I., Dingari, N. C., Kang, J. W., Horowitz, G. L., Dasari, R. R., & Feld, M. S. (2012) · Analytical Chemistry · doi:10.1021/ac203266a · Cited by 139
Berry, B. N., Dobrowsky, T. M., Timson, R. C., Kshirsagar, R., Ryll, T., & Wiltberger, K. (2016) · Biotechnology Progress · doi:10.1002/btpr.2205 · Cited by 135
Recent advances in the application of transmission Raman spectroscopy to pharmaceutical analysis
Buckley, K., & Matousek, P. (2010) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2010.10.029 · Cited by 134 · cited 1×
“), small particles/samples can be probed, and there is potential to automate both the signal collection and data analysis.(207,208) Noninvasive Raman measurements through glass(207) and plastic, or in turbid media(209,210) are also possible.”
Self-citationSaggu, M., Liu, J., & Patel, A. R. (2015) · Pharmaceutical Research · doi:10.1007/s11095-015-1670-x · Cited by 134 · cited 1×
“…sub-visible particles in biopharmaceutical formulations (the spectra were used to elucidate the particle-formation mechanism in a test system) 203 and an automated Raman system has also been deployed to identify silicone-oil induced aggregation of proteins in drug solutions (it was…”
New limits in ultrasensitive trace detection by surface enhanced Raman scattering (SERS)
Etchegoin, P., Maher, R. C., Cohen, L. F., Hartigan, H., Brown, R. J. C., Milton, M. J. T., & Gallop, J. C. (2003) · Chemical Physics Letters · doi:10.1016/s0009-2614(03)00821-2 · Cited by 130
Li, C. H., Nguyen, X. C., Narhi, L. O., Chemmalil, L., Towers, E., Muzammil, S., Gabrielson, J. P., & Jiang, Y. (2011) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.22695 · Cited by 127 · cited 1×
“25,26 In some cases, after a molecule absorbs a photon of appropriate energy and is in an excited singlet state, it can return to the ground singlet state via the emission of a photon in a process known as fluorescence.”
Near Infrared Spectroscopy for Bioprocess Monitoring and Control: Current Status and Future Trends
Scarff, M., Arnold, S. A., Harvey, L. M., & McNeil, B. (2006) · Critical Reviews in Biotechnology · doi:10.1080/07388550500513677 · Cited by 124 · cited 1×
“Second, the lower molar absorptivity of most molecules in the NIR region allows for longer sample path-lengths/more homogeneous sampling, and can facilitate sampling through relatively thick container walls.(45,46) In BioPharma, NIR’s main application tends to focus on either raw material testing,(6) or process monito…”
Sivakesava, S., Irudayaraj, J., & Demırcı, A. (2001) · Process Biochemistry · doi:10.1016/s0032-9592(01)00223-0 · Cited by 119
Multivariate data analysis for Raman spectroscopic imaging
Shinzawa, H., Awa, K., Kanematsu, W., & Ozaki, Y. (2009) · Journal of Raman Spectroscopy · doi:10.1002/jrs.2525 · Cited by 119
Allegrini, F., & Olivieri, A. C. (2011) · Analytica Chimica Acta · doi:10.1016/j.aca.2011.04.061 · Cited by 119
Mikhonin, A. V., Ahmed, Z., Ianoul, A. I., & Asher, S. A. (2004) · The Journal of Physical Chemistry B · doi:10.1021/jp045959d · Cited by 117 · cited 1×
“74 Many biologically important molecules such as amino acids, 79–81 peptides, 82,83 and nucleotides, 84,85 produce highly selective resonance Raman effects.”
Sane, S. U., Wong, R., & Hsu, C. C. (2004) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.20014 · Cited by 116 · cited 1×
“193 A few years later, De Beer et al. demonstrated that Raman could be used for the in-line and real-time monitoring of freeze-drying.”
Geladi, P. L. M., Lindholm‐Sethson, B., Nyström, J., Lillhonga, T., Lestander, T. A., & Burger, J. (2004) · Spectrochimica Acta Part B Atomic Spectroscopy · doi:10.1016/j.sab.2004.06.009 · Cited by 111 · cited 1×
“The most widely used regression based method for quantitative analysis of Raman data is partial least squares (PLS) 99,100,122–124 and derivatives thereof.”
Léger, M. N., & Ryder, A. G. (2006) · Applied Spectroscopy · doi:10.1366/000370206776023304 · Cited by 109
Self-citationGeneric Raman‐based calibration models enabling real‐time monitoring of cell culture bioreactors
Mehdizadeh, H., Lauri, D., Karry, K. M., Moshgbar, M., Procopio‐Melino, R., & Drapeau, D. (2015) · Biotechnology Progress · doi:10.1002/btpr.2079 · Cited by 108
Olds, W. J., Jaatinen, E. A., Fredericks, P. M., Cletus, B., Panayiotou, H., & Izake, E. L. (2011) · Forensic Science International · doi:10.1016/j.forsciint.2011.05.016 · Cited by 107
Jarvis, R. M., & Goodacre, R. (2004) · FEMS Microbiology Letters · doi:10.1016/s0378-1097(04)00040-0 · Cited by 105
The development of biomolecular Raman optical activity spectroscopy
Barron, L. D. (2015) · Biomedical Spectroscopy and Imaging · doi:10.3233/bsi-150113 · Cited by 104 · cited 2×
“The equivalent Raman method, ROA can provide very useful structural information: in the small molecule domain providing data about chirality, and for biomolecules additional information about 3D structure.(96) ROA has been applied to the studying the effect of crowding on protein structure(97) and thermal stress effec…”
Matthews, T. E., Berry, B. N., Smelko, J., Moretto, J., Moore, B., & Wiltberger, K. (2016) · Biotechnology and Bioengineering · doi:10.1002/bit.26018 · Cited by 104
Ant colony optimisation: a powerful tool for wavelength selection
Shamsipur, M., Zare-Shahabadi, V., Hemmateenejad, B., & Akhond, M. (2006) · Journal of Chemometrics · doi:10.1002/cem.1002 · Cited by 104 · cited 1×
“As with all other aspects of chemometrics, there are many different algorithms that can be used for variable selection, 112–115 in our group ant colony optimization (ACO) 116–118 has been used most often.”
Baumann, K., Albert, H., & von Korff, M. (2002) · Journal of Chemometrics · doi:10.1002/cem.730 · Cited by 104
In situ bioprocess monitoring of Escherichia coli bioreactions using Raman spectroscopy
Lee, H. L. T., Boccazzi, P., Gorret, N., Ram, R. J., & Sinskey, A. J. (2004) · Vibrational Spectroscopy · doi:10.1016/j.vibspec.2003.12.015 · Cited by 102 · cited 3×
“They showed that number of different molecular analytes (including glucose, phenylalanine, acetate, formate, and lactate; Figure 6) could be quantified and that the measured concentrations compared well with reference HPLC measurements (Table 2).(55) In general, the liquid in a bioreactor progresses from translucent t…”
Martyshkin, D. V., Ahuja, R. C., Kudriavtsev, A., & Mirov, S. (2004) · Review of Scientific Instruments · doi:10.1063/1.1646743 · Cited by 97 · cited 1×
“This approach was demonstrated more than a decade ago but the instrumentation was expensive, complicated, and not commercialized 61,62 (diode arrays had been mooted and demonstrated as a potential solution to the problem in the 1980s but suffered from technology limitations at the time 63 ).”
CE‐MS for the analysis of intact proteins 2010–2012
Haselberg, R., de Jong, G. J., & Somsen, G. W. (2013) · ELECTROPHORESIS · doi:10.1002/elps.201200439 · Cited by 96 · cited 1×
“Again, these combined MS/chromatography technologies are widely adopted and are the subject of much scientific literature (e.g., HPLC-MS, 15,16 UHPLC-MS, 17,18 CE-MS 19,20 ).”
Bush, D. R., Zang, L., Belov, A. M., Ivanov, A. R., & Karger, B. L. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b03218 · Cited by 92
Li, B., Ryan, P. W., Ray, B. H., Leister, K. J., Sirimuthu, N. M. S., & Ryder, A. G. (2010) · Biotechnology and Bioengineering · doi:10.1002/bit.22813 · Cited by 91
Self-citationMass spectrometry for glycosylation analysis of biopharmaceuticals
Dotz, V., Haselberg, R., Shubhakar, A., Kozak, R. P., Falck, D., Rombouts, Y., Reusch, D., Somsen, G. W., Fernandes, D. L., & Wuhrer, M. (2015) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.04.024 · Cited by 89 · cited 1×
“13 Most of the measuring/monitoring of post-translational modifications (e.g., the differentiation of glycosylated forms 13 of native proteins) in BioPharma is MS-based and there is not a very extensive literature related to spectroscopic methods.”
Bobst, C. E., Abzalimov, R. R., Houde, D., Kloczewiak, M., Mhatre, R., Berkowitz, S. A., & Kaltashov, I. A. (2008) · Analytical Chemistry · doi:10.1021/ac801214x · Cited by 85 · cited 1×
“12–14 Mass spectrometry techniques are often coupled with chromatographic separation techniques producing methods that have very high analyte resolution which are often the best means of characterizing complex biological samples in detail.”
Hédoux, A. (2015) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2015.11.021 · Cited by 85 · cited 1×
“These studies illustrate how the fundamental strengths of Raman (minimal sample handling, molecular specificity, online/non-contact) can be exploited to produce very useful information for protein formulation.(198) Recent developments in filter technologies which enable Raman measurements in the <100 cm spectral regio…”
Shaw, A. D., Kaderbhai, N., Jones, A., Woodward, A. M., Goodacre, R., Rowland, J. J., & Kell, D. B. (1999) · Applied Spectroscopy · doi:10.1366/0003702991945777 · Cited by 84 · cited 1×
“Much of the early works focused on the production of simpler molecules, such as yeast-based fermentations for the production of ethanol, 153–155 and other products such as plant hormones 156 and a carotenoid antioxidant.”
In-line and real-time prediction of recombinant antibody titer by in situ Raman spectroscopy
André, S., Cristau, L. S., Gaillard, S., Devos, O., Calvosa, É., & Duponchel, L. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.08.050 · Cited by 84 · cited 1×
“Since the first offline Raman analysis of spent cell culture media in the late 1990s, the technology has progressed to a point where the bioreactor broth is now analyzed in real time,(159,163) and the yield of a bioprocess could be predicted.(118,165) In 2014, Craven et al.”
McGovern, A. C., Broadhurst, D., Taylor, J., Kaderbhai, N., Winson, M. K., Small, D. A., Rowland, J. J., Kell, D. B., & Goodacre, R. (2002) · Biotechnology and Bioengineering · doi:10.1002/bit.10226 · Cited by 83 · cited 1×
“Much of the early works focused on the production of simpler molecules, such as yeast-based fermentations for the production of ethanol, 153–155 and other products such as plant hormones 156 and a carotenoid antioxidant.”
UV Raman Spectral Intensities of E. Coli and Other Bacteria Excited at 228.9, 244.0, and 248.2 nm
Wu, Q., Hamilton, T., Nelson, W. H., Elliott, S., Sperry, J. F., & Wu, M. T. (2001) · Analytical Chemistry · doi:10.1021/ac001268b · Cited by 78
Analysis of luminescent samples using subtracted shifted Raman spectroscopy
Bell, S. E. J., Bourguignon, E., & Dennis, A. C. (1998) · The Analyst · doi:10.1039/a802802h · Cited by 78 · cited 1×
“…as modulated Raman spectroscopy, 65 shifted excitation Raman difference spectroscopy (SERDS), 66 and subtracted shifted Raman spectroscopy (SSRS), 67 are intrinsically limited by the fact that fluorescence and Raman photons are measured simultaneously, and thus shot noise contributions cannot be…”
Proteins behaving badly: emerging technologies in profiling biopharmaceutical aggregation
Hamrang, Z., Rattray, N. J. W., & Pluen, A. (2013) · Trends in Biotechnology · doi:10.1016/j.tibtech.2013.05.004 · Cited by 75 · cited 1×
“It is therefore very important to monitor the protein so as to ensure that no unwanted structural changes or aggregation have been induced.(129,188) Raman spectroscopy offers some useful characterization of the larger aggregates which can be analyzed using confocal microscopy-based instruments.”
Non-invasive analysis of turbid samples using deep Raman spectroscopy
Buckley, K., & Matousek, P. (2010) · The Analyst · doi:10.1039/c0an00723d · Cited by 74 · cited 1×
“207,208 Non-invasive Raman measurements through glass 207 and plastic, or in turbid media 209,210 are also possible.”
Self-citationPrediction of Cell Culture Media Performance Using Fluorescence Spectroscopy
Ryan, P. W., Li, B., Shanahan, M., Leister, K. J., & Ryder, A. G. (2010) · Analytical Chemistry · doi:10.1021/ac902337c · Cited by 73 · cited 6×
“Inline monitoring has shown utility for collecting continuous and instantaneous data (when compared to the long duration of a typical mammalian cell culture, ten or more days), and both forms of bioprocesses monitoring have demonstrated that they can provide useful information on the scale-up of fed-batch processes (t…”
InfluentialSelf-citationUltra-high-performance liquid chromatography for the characterization of therapeutic proteins
Fekete, S., & Guillarme, D. (2014) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2014.05.012 · Cited by 73
On‐line monitoring of Phaffia rhodozyma fed‐batch process with in situ dispersive raman spectroscopy
Cannizzaro, C., Rhiel, M., Marison, I., & von Stockar, U. (2003) · Biotechnology and Bioengineering · doi:10.1002/bit.10698 · Cited by 70 · cited 1×
“157 In most of these studies, the product molecule produced a reasonably strong Raman signal that had bands distinct from the (broad, less well defined) background.”
Performance monitoring of a mammalian cell based bioprocess using Raman spectroscopy
Li, B., Ray, B. H., Leister, K. J., & Ryder, A. G. (2013) · Analytica Chimica Acta · doi:10.1016/j.aca.2013.07.058 · Cited by 67 · cited 7×
“However, because of the compositional complexity, weakness of the signals, and band overlap, it was not possible to say conclusively which specific molecular component was most correlated with yield.(118) Our suspicion was that the cell culture media variance was the key factor, and we proposed that predictive process…”
InfluentialSelf-citationChemometrics applications in biotech processes: A review
Rathore, A. S., Bhushan, N., & Hadpe, S. R. (2011) · Biotechnology Progress · doi:10.1002/btpr.561 · Cited by 66 · cited 1×
“105 Chemometrics covers a vast array of methods and applications including experimental design, spectral pre-processing, qualitative/qualitative analysis of variance, and quantitative analysis of specific components in samples.”
Hakemeyer, C., Strauss, U. T., Werz, S., José, G. E., Folque, F., & de Menezes, J. C. (2011) · Talanta · doi:10.1016/j.talanta.2011.12.042 · Cited by 65
Luo, Y., & Chen, G. (2007) · Biotechnology and Bioengineering · doi:10.1002/bit.21365 · Cited by 64
Towards real-time monitoring of therapeutic protein quality in mammalian cell processes
Pais, D. A. M., Carrondo, M. J. T., Alves, P. M., & Teixeira, A. P. (2014) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2014.06.019 · Cited by 63 · cited 1×
“These regulatory demands have led to the adoption of smarter process-management systems (such as Quality by Design [QbD](4) and process analytical technology [PAT](5,6)) and to increased need for new/novel analytical technologies.(7) Governments and lawmakers are also stakeholders because they want to see efficiencies…”
Monitoring the Glycosylation Status of Proteins Using Raman Spectroscopy
Brewster, V. L., Ashton, L., & Goodacre, R. (2011) · Analytical Chemistry · doi:10.1021/ac2012009 · Cited by 60
HPLC, a practical user's guide
(1995) · Choice Reviews Online · doi:10.5860/choice.32-3317 · Cited by 60 · cited 1×
“Finally, the huge volume of information generated by the hyphenated analytical methods like LC-MS can cause difficulties in interpretation and analysis, often dedicated scientific staff are required for the purpose.(21) These issues, when combined with high capital acquisition costs, can result in relatively expensive…”
Secondary Structure and Glycosylation of Mucus Glycoproteins by Raman Spectroscopies
Davies-Strickleton, H., Singh, P., Deckert‐Gaudig, T., Deckert, V., Rousseau, K., Ridley, C. E., Dowd, S. E., Doig, A. J., Pudney, P. D. A., Thornton, D. J., et al. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b03095 · Cited by 59 · cited 1×
“183 Unfortunately, the implementation of a Raman spectro-scopy-based method capable of displacing MS-based meth-ods for MAb glycosylation analysis is likely to prove impossible for the time-being.”
Wen, Z., Li, G., & Ren, D. H. (2011) · Applied Spectroscopy · doi:10.1366/10-06089 · Cited by 55 · cited 1×
“138 This is one of the critical issues associated with SERS analysis of complex liquids, only certain analytes will be adsorbed and the spectra will be dominated by their signal.”
Liu, Y.-J., André, S., Saint Cristau, L., Lagresle, S., Hannas, Z., Calvosa, É., Devos, O., & Duponchel, L. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.11.064 · Cited by 54
SCHENK, J., MARISON, I., & VONSTOCKAR, U. (2007) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2006.09.015 · Cited by 53
Modulated Raman Spectroscopy for Enhanced Cancer Diagnosis at the Cellular Level
Luca, A. C. D., Dholakia, K., & Mazilu, M. (2015) · Sensors · doi:10.3390/s150613680 · Cited by 52 · cited 1×
“Many of the other methods for dealing with fluorescence, such as modulated Raman spectroscopy, 65 shifted excitation Raman difference spectroscopy (SERDS), 66 and subtracted shifted Raman spectroscopy (SSRS), 67 are intrinsically limited by the fact that fluorescence and Raman photons are measured…”
Detection of Protein Glycosylation Using Tip-Enhanced Raman Scattering
Cowcher, D. P., Deckert‐Gaudig, T., Brewster, V. L., Ashton, L., Deckert, V., & Goodacre, R. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b03535 · Cited by 51 · cited 1×
“182 Finally, the combination of TERS, ROA, and CD spectroscopies was used successfully to study some aspects of the structure and glycosylation of mucin proteins.”
Bults, P., van de Merbel, N. C., & Bischoff, R. (2015) · Expert Review of Proteomics · doi:10.1586/14789450.2015.1050384 · Cited by 49
Li, B., Calvet, A., Casamayou-Boucau, Y., Morris, C., & Ryder, A. G. (2015) · Analytical Chemistry · doi:10.1021/ac504776m · Cited by 47 · cited 1×
“207 In two recent solid-state analysis studies we collected nearly 1 million spectra, 211 and (cid:2) 9 million Raman spectra (as yet unpublished results) in experiments over a timeframe of three to six months.”
Self-citationCalvet, A., & Ryder, A. G. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.06.021 · Cited by 46 · cited 3×
“It was shown that CRS was unable to detect the small chemical changes associated with the degradation but that SERS could detect some changes and in particular the variances associated with the cysteine/cystine concentration.(73) The SERS substrate used in the study was a simple silver colloid, which offered a reasona…”
Self-citationThe Direct Analysis of Fermentation Products by Raman Spectroscopy
Shope, T. B., Vickers, T. J., & Mann, C. K. (1987) · Applied Spectroscopy · doi:10.1366/0003702874448373 · Cited by 42 · cited 1×
“Much of the early works focused on the production of simpler molecules, such as yeast-based fermentations for the production of ethanol, 153–155 and other products such as plant hormones 156 and a carotenoid antioxidant.”
Wang, X., Morgan, D. M., Wang, G., & Mozier, N. M. (2012) · Biotechnology and Bioengineering · doi:10.1002/bit.23343 · Cited by 41 · cited 1×
“The latter study was very significant because host-cell DNA/RNA have the potential to induce serious adverse clinical effects and have been the subject of much scientific research.(205)”
Li, B., Shanahan, M., Calvet, A., Leister, K. J., & Ryder, A. G. (2014) · The Analyst · doi:10.1039/c4an00007b · Cited by 41 · cited 3×
“The samples had the cells and solid debris removed by centrifugation/filtration and were examined using CRS with 785 nm excitation (the same sample set was also analyzed by fluorescence EEM).(36) The spectral data set, which contained variation due to changes in molecular composition as the process progressed (12 step…”
Self-citationLi, B., Ryan, P. W., Shanahan, M., Leister, K. J., & Ryder, A. G. (2011) · Applied Spectroscopy · doi:10.1366/11-06383 · Cited by 41
Self-citationCalvet, A., Li, B., & Ryder, A. G. (2012) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2012.08.002 · Cited by 40 · cited 1×
“fluorescence-based techniques high sensitivity and good signal-to-noise (S/N) ratios; routine assays that use conventional spectrometers can have limit of detection (LoD) down in the nanomolar concentration range.(28,29) This sensitivity has been exploited to produce methods with single molecule detection such as fluo…”
Self-citationLi, B., Sirimuthu, N. M. S., Ray, B. H., & Ryder, A. G. (2011) · Journal of Raman Spectroscopy · doi:10.1002/jrs.3141 · Cited by 40 · cited 6×
“Conventional Raman spectroscopy is not suitable for the analysis of most types of yeastolate because of its very strong fluorescence.(35) The use of longer excitation wavelength (993, 1064 nm) light can reduce the effect, but the Raman signal tends to be weak and adversely affected by the considerable shot noise from…”
InfluentialSelf-citationDabros, M., Amrhein, M., Bonvin, D., Marison, I. W., & von Stockar, U. (2009) · Biotechnology Progress · doi:10.1002/btpr.143 · Cited by 39
Calvet, A., Li, B., & Ryder, A. G. (2013) · Analytica Chimica Acta · doi:10.1016/j.aca.2013.11.028 · Cited by 38 · cited 2×
“Media are inherently unstable in the liquid state, and despite being stored at low temperature (typically 2–8 C), significant compositional variation can appear over time (even when stored sterile, in the dark).(34,133) Recently, the possibility of monitoring cell culture media degradation using Raman spectroscopy was…”
Self-citationData fusion‐based assessment of raw materials in mammalian cell culture
Lee, H. W., Christie, A., Xu, J., & Yoon, S. (2012) · Biotechnology and Bioengineering · doi:10.1002/bit.24548 · Cited by 37 · cited 1×
“In addition, a model combining all the analytical data was presented; it gave the best prediction accuracy and demonstrated the synergetic effects of data fusion in characterizing the raw material quality.(144) The key outcome was that process performance could be predicted on the basis of the measured spectral varian…”
Gupta, A. J., Hageman, J. A., Wierenga, P. A., Boots, J.-W. P., & Gruppen, H. (2013) · Process Biochemistry · doi:10.1016/j.procbio.2013.10.013 · Cited by 36
Gupta, A. J., Gruppen, H., Maes, D., Boots, J.-W. P., & Wierenga, P. A. (2013) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf403051z · Cited by 34 · cited 1×
“In addition, some bioprocesses also require the addition of complex biological derived additives, such as fetal bovine serum (FBS), proteins (e.g., bovine serum albumin), or hydrolysates (e.g., soy 132 or yeast).”
de la Cuesta, R. G., Goodacre, R., & Ashton, L. (2014) · Analytical Chemistry · doi:10.1021/ac5038329 · Cited by 34
A stainless steel multi‐well plate (SS‐MWP) for high‐throughput Raman analysis of dilute solutions
Ryder, A. G., Vincentis, J. D., Li, B., Ryan, P. W., Sirimuthu, N. M. S., & Leister, K. J. (2010) · Journal of Raman Spectroscopy · doi:10.1002/jrs.2586 · Cited by 33
Self-citationThe challenge of applying Raman spectroscopy to monitor recombinant antibody production
Ashton, L., Yun Xu, A., Brewster, V. L., Cowcher, D. P., Sellick, C. A., Dickson, A. J., Stephens, G., & Goodacre, R. (2013) · The Analyst · doi:10.1039/c3an01341c · Cited by 33
Fluorescence rejection in Raman spectroscopy using a gated intensified diode array detector
Everall, N. J., Jackson, R. W., Howard, J. A. K., & Hutchinson, K. (1986) · Journal of Raman Spectroscopy · doi:10.1002/jrs.1250170507 · Cited by 33 · cited 1×
“This approach was demonstrated more than a decade ago but the instrumentation was expensive, complicated, and not commercialized 61,62 (diode arrays had been mooted and demonstrated as a potential solution to the problem in the 1980s but suffered from technology limitations at the time 63 ).”
Ota, C., Noguchi, S., Nagatoishi, S., & Tsumoto, K. (2015) · Pharmaceutical Research · doi:10.1007/s11095-015-1842-8 · Cited by 32 · cited 1×
“195 Other recent studies by Ota et al., 196,197 demonstrated that CRS using visible excitation can be used to easily analyze with a relatively high level of detail, high protein concentration solutions (up to (cid:2) 300 mg/mL) and that CRS combined with straightforward chemometric (PCA and MCR)…”
Thiagarajan, G., Widjaja, E., Heo, J. H., Cheung, J. K., Wabuyele, B., Mou, X., & Shameem, M. (2015) · Journal of Raman Spectroscopy · doi:10.1002/jrs.4679 · Cited by 31
Brewster, V. L., Ashton, L., & Goodacre, R. (2013) · Analytical Chemistry · doi:10.1021/ac303265q · Cited by 31 · cited 1×
“170,190 The following year, they demonstrated that CRS combined with 2D perturbation-correlation moving windows (PCMW) data analysis could be used to characterize conformational transitions in antibodies.”
A fluorescence anisotropy method for measuring protein concentration in complex cell culture media
Groza, R. C., Calvet, A., & Ryder, A. G. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.03.007 · Cited by 28 · cited 1×
“EEM has been combined with chemometrics to provide a very effective and useful tool for the qualitative characterization of nearly all the liquid materials that are encountered in biopharmaceutical manufacturing: analyses of cell culture media; biogenic raw materials;(35) bioprocess broths;(36) and proteins.(37) This…”
Self-citationWen, Z., Cao, X., & Vance, A. (2007) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.21191 · Cited by 28 · cited 1×
“These cationp interactions in proteins have been recognized as playing an important role in protein structural stability and in protein– protein interaction between ligand and receptors.(179)”
Mammalian cell culture monitoring using in situ spectroscopy: Is your method really optimised?
André, S., Lagresle, S., Hannas, Z., Calvosa, É., & Duponchel, L. (2017) · Biotechnology Progress · doi:10.1002/btpr.2430 · Cited by 27
Ota, C., Noguchi, S., & Tsumoto, K. (2015) · Biopolymers · doi:10.1002/bip.22593 · Cited by 27 · cited 1×
“195 Other recent studies by Ota et al., 196,197 demonstrated that CRS using visible excitation can be used to easily analyze with a relatively high level of detail, high protein concentration solutions (up to (cid:2) 300 mg/mL) and that CRS combined with straightforward chemometric (PCA and MCR)…”
Bioanalysis and Biosensors for Bioprocess Monitoring
Sonnleitner, B. (2000) · Advances in biochemical engineering, biotechnology · doi:10.1007/3-540-48773-5 · Cited by 26
Roessl, U., Leitgeb, S., Pieters, S., Beer, T. D., & Nidetzky, B. (2014) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.24072 · Cited by 25
Raman spectroscopy of complex defined media: biopharmaceutical applications
Singh, G., Goh, S., Canzoneri, M., & Ram, R. J. (2015) · Journal of Raman Spectroscopy · doi:10.1002/jrs.4686 · Cited by 24 · cited 1×
“A recent study attempted to demonstrate the feasibility of using an explicit model-based classical least squares (CLS) algorithm and a spectral-library of media components.(151) With this approach, known analyte spectra were fitted to the measured spectra of the sample liquid (supernatant extracted from a cell culture…”
Galvão, R. K. H., & de Araújo, M. C. U. (2009) · Elsevier eBooks · doi:10.1016/b978-044452701-1.00075-2 · Cited by 24
Li, B., Calvet, A., Casamayou-Boucau, Y., & Ryder, A. G. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.01.042 · Cited by 24
Self-citationLuo, Y., & Pierce, K. M. (2012) · Biotechnology Progress · doi:10.1002/btpr.1568 · Cited by 23
Cao, X., Wen, Z., Vance, A., & Torraca, G. (2009) · Applied Spectroscopy · doi:10.1366/000370209788701026 · Cited by 23 · cited 1×
“Raman has shown utility for the identification, in situ, of foreign particulates that have formed (in aqueous solutions) inside glass containers; of droplet-like particles inside prefilled glass syringes, of fibrous particles inside glass test tubes, and of specks of an unknown white substance inside glass vials.(201,…”
Gomy, C., Jouan, M. D., & Dao, N. Q. (1988) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)85279-4 · Cited by 23
Shashilov, V. A., Xu, M., Makarava, N., Savtchenko, R. S., Baskakov, I. V., & Lednev, I. K. (2012) · The Journal of Physical Chemistry B · doi:10.1021/jp2122455 · Cited by 23
Anisotropy resolved multidimensional emission spectroscopy (ARMES): A new tool for protein analysis
Groza, R. C., Li, B., & Ryder, A. G. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.06.011 · Cited by 23
Self-citationAshton, L., Hogwood, C. E. M., Tait, A. S., Kuligowski, J., Smales, C. M., Bracewell, D. G., Dickson, A. J., & Goodacre, R. (2014) · Journal of Chemical Technology & Biotechnology · doi:10.1002/jctb.4420 · Cited by 22 · cited 1×
“206 The latter study was very significant because host-cell DNA/RNA have the potential to induce serious adverse clinical effects p and have been the subject of much scientific research.”
Lyubarskaya, Y. V., Kobayashi, K., & Swann, P. G. (2015) · Pharmaceutical Bioprocessing · doi:10.4155/pbp.15.10 · Cited by 13 · cited 1×
“12–14 Mass spectrometry techniques are often coupled with chromatographic separation techniques producing methods that have very high analyte resolution which are often the best means of characterizing complex biological samples in detail.”
Lankers, M., Munhall, J., & Valet, O. K. (2008) · Microscopy and Microanalysis · doi:10.1017/s1431927608086807 · Cited by 12 · cited 1×
“Recently, CRS has also been used to identify sub-visible particles in biopharmaceutical formulations (the spectra were used to elucidate the particleformation mechanism in a test system)(203) and an automated Raman system has also been deployed to identify siliconeoil induced aggregation of proteins in drug solutions…”
Oshokoya, O. O., & JiJi, R. D. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.08.035 · Cited by 12 · cited 1×
“121 Both methods are commonly applied to the analysis of Raman data and can be used for both reaction monitoring (most significantly for small molecule synthesis) and structural analysis of proteins.”
Hédoux, A., Seo, J., Guinet, Y., & Paccou, L. (2011) · Journal of Raman Spectroscopy · doi:10.1002/jrs.3009 · Cited by 11
Application of spectroscopic methods for the automation of oil palm culture.
Willis, L. B., Gil, G., Lee, H. L. T., Choi, D.-H., Schoenheit, J., Ram, R. J., Rha, C., & Sinskey, A. J. (2008) · Journal of Oil Palm Research · Cited by 10
Arzhantsev, S., Vilker, V. L., & Kauffman, J. F. (2012) · Applied Spectroscopy · doi:10.1366/11-06572 · Cited by 9 · cited 1×
“The study showed that these primary structure variations were manifested as differences in secondary structure and that this could be detected by UVRRS, the authors concluded that the method could be used as a direct characterization tool for formulation quality control.(178) It has also been demonstrated that Raman s…”
Patois, E., Larmour, I. A., Bell, S. E. J., Palais, C., Capelle, M. A. H., Gurny, R., & Arvinte, T. (2012) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2012.02.016 · Cited by 5
R aman Spectroscopy of Polymers
Paradkar, R. P., Leugers, A., Patel, R. M., Chen, X., Meyers, G. F., & Lipp, E. D. (2009) · Wiley eBooks · doi:10.1002/9780470027318.a9032 · Cited by 3 · cited 1×
“52,54 Many of these applications are now very mature and can be easily deployed into different settings; for example, the application of Raman spectroscopy for polymer and fiber analysis 125,126 and knowledge in this area can be used in the identification of foreign bodies in APIs.”
Cited by
Time-gated Raman spectroscopy – a review
Kögler, M., & Heilala, B. (2020) · Measurement Science and Technology · doi:10.1088/1361-6501/abb044 · Cited by 107
Raman Spectroscopy and Its Modifications Applied to Biological and Medical Research
Allakhverdiev, E. S., Khabatova, V. V., Kossalbayev, B. D., Zadneprovskaya, E. V., Rodnenkov, O. V., Martynyuk, T. V., Maksimov, G. V., Alwasel, S., Tomo, T., & Allakhverdiev, S. I. (2022) · Cells · doi:10.3390/cells11030386 · Cited by 88
Tulsyan, A., Schorner, G., Khodabandehlou, H., Wang, T., Coufal, M., & Undey, C. (2019) · Biotechnology and Bioengineering · doi:10.1002/bit.27100 · Cited by 82
Kornecki, M., & Strube, J. (2018) · Bioengineering · doi:10.3390/bioengineering5010025 · Cited by 61
“Methods are available that can acquire spectra and integrate them into PLS models, resulting in the online determination of viable cell, substrate, and metabolite concentrations [46,47].”
BackgroundRecent application of spectroscopy for the detection of microalgae life information: A review
Liu, J.-Y., Zeng, L.-H., & Ren, Z.-H. (2020) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2018.1509345 · Cited by 59
Metadata
- Authors
- Buckley, K., & Ryder, A. G.
- Venue
- Applied Spectroscopy
- Publisher
- SAGE Publications
- Published
- 2017-05-23
- Volume
- 71
- Issue
- 6
- Pages
- 1085-1116
- ISSN
- 0003-7028 (ISSN-L)
- 1943-3530
- OpenAlex
- W2618036898
- Cited by
- 160
- References
- 170
- FWCI
- 8.39
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.