Biomechanical properties of knee articular cartilage
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Structure and properties of knee articular cartilage are adapted to stresses exposed on it during physiological activities. In this study, we describe site‐ and depth‐dependence of the biomechanical properties of bovine knee articular cartilage. We also investigate the effects of tissue structure and composition on the biomechanical parameters as well as characterize experimentally and numerically the compression–tension nonlinearity of the cartilage matrix. In vitro mechano‐optical measurements of articular cartilage in unconfined compression geometry are conducted to obtain material parameters, such as thickness, Young's and aggregate modulus or Poisson's ratio of the tissue. The experimental results revealed significant site‐ and depth‐dependent variations in recorded parameters. After enzymatic modification of matrix collagen or proteoglycans our results show that collagen primarily controls the dynamic tissue response while proteoglycans affect more the static properties. Experimental measurements in compression and tension suggest a nonlinear compression–tension behavior of articular cartilage in the direction perpendicular to articular surface. Fibril reinforced poroelastic finite element model was used to capture the experimentally found compression–tension nonlinearity of articular cartilage.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biphasic Creep and Stress Relaxation of Articular Cartilage in Compression: Theory and Experiments
Mow, V. C., Kuei, S. C., Lai, W. M., & Armstrong, C. G. (1980) · Journal of Biomechanical Engineering · doi:10.1115/1.3138202 · Cited by 2,444 · cited 2×
“As a next step the isotropic biphasic solution [25,29] could also explain the time dependence of the cartilage mechanical behaviour.”
Fluid transport and mechanical properties of articular cartilage: A review
Mow, V. C., Holmes, M. H., & Michael Lai, W. (1984) · Journal of Biomechanics · doi:10.1016/0021-9290(84)90031-9 · Cited by 1,024 · cited 2×
“The elastic modulus of articular cartilage is typically 0.3–1.5 MPa [2,11,30,32].”
InfluentialA mathematical analysis for indentation tests of articular cartilage
Hayes, W. C., Keer, L. M., Herrmann, G., & Mockros, L. F. (1972) · Journal of Biomechanics · doi:10.1016/0021-9290(72)90010-3 · Cited by 967 · cited 1×
“The first models were isotropic and elastic [9] and could be applied only to characterize the instantaneous or equilibrium responses of cartilage after a stepload application.”
Armstrong, C. G., & Mow, V. C. (1982) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198264010-00013 · Cited by 770 · cited 1×
“The compressive stiffness of cartilage is positively related to GAG concentration and negatively related to the hydration of the tissue [1,14].”
BUCKWALTER, J. A., & MANKIN, H. J. (1997) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199704000-00022 · Cited by 755
Depth‐dependent confined compression modulus of full‐thickness bovine articular cartilage
Schinagl, R. M., Gurskis, D., Chen, A. C., & Sah, R. L. (1997) · Journal of Orthopaedic Research · doi:10.1002/jor.1100150404 · Cited by 646 · cited 1×
“Also a significant depth-dependence in compressive stiffness of cartilage has been revealed [35].”
Contact pressures in the human hip joint measured in vivo.
Hodge, W. A., Fijan, R. S., Carlson, K. L., Burgess, R. G., Harris, W. H., & Mann, R. W. (1986) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.83.9.2879 · Cited by 623 · cited 1×
“during dynamic loads have been measured [10].”
Soltz, M. A., & Ateshian, G. A. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00105-5 · Cited by 504
Biphasic indentation of articular cartilage—I. Theoretical analysis
Mak, A. F., Lai, W. M., & Mow, V. C. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90036-4 · Cited by 478 · cited 1×
“As a next step the isotropic biphasic solution [25,29] could also explain the time dependence of the cartilage mechanical behaviour.”
KEMPSON, G., MUIR, H., POLLARD, C., & TUKE, M. (1973) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(73)90093-7 · Cited by 453 · cited 1×
“It is known that collagen meshwork is predominantly responsible for the tensile and shear properties of the tissue while the proteoglycans are main determinants of the compressive stiffness [14–16].”
Cited by
Moroni, L., de Wijn, J. R., & van Blitterswijk, C. A. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.07.023 · Cited by 534
Strategic Design and Fabrication of Engineered Scaffolds for Articular Cartilage Repair
Izadifar, Z., Chen, X., & Kulyk, W. (2012) · Journal of Functional Biomaterials · doi:10.3390/jfb3040799 · Cited by 203
Nanocellulose-Based Interpenetrating Polymer Network (IPN) Hydrogels for Cartilage Applications
Naseri, N., Deepa, B., Mathew, A. P., Oksman, K., & Girandon, L. (2016) · Biomacromolecules · doi:10.1021/acs.biomac.6b01243 · Cited by 186
Fabrication of a multi-layered decellularized amniotic membranes as tissue engineering constructs
Yüksel, S., Aşık, M. D., Aydin, H. M., Tönük, E., Aydın, E. Y., & Bozkurt, M. (2022) · Tissue and Cell · doi:10.1016/j.tice.2021.101693 · Cited by 6
Metadata
- Authors
- Laasanen, M. S., Töyräs, J., Korhonen, R. K., Rieppo, J., Saarakkala, S., Nieminen, M. T., Hirvonen, J., & Jurvelin, J. S.
- Venue
- Biorheology: The Official Journal of the International Society of Biorheology
- Publisher
- SAGE Publications
- Published
- 2003-01
- Volume
- 40
- Issue
- 1-3
- Pages
- 133-140
- ISSN
- 0006-355X (ISSN-L)
- 1878-5034
- OpenAlex
- W1779199741
- Cited by
- 212
- References
- 26
- FWCI
- 7.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.