Biomechanical properties of knee articular cartilage
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Structure and properties of knee articular cartilage are adapted to stresses exposed on it during physiological activities. In this study, we describe site‐ and depth‐dependence of the biomechanical properties of bovine knee articular cartilage. We also investigate the effects of tissue structure and composition on the biomechanical parameters as well as characterize experimentally and numerically the compression–tension nonlinearity of the cartilage matrix. In vitro mechano‐optical measurements of articular cartilage in unconfined compression geometry are conducted to obtain material parameters, such as thickness, Young's and aggregate modulus or Poisson's ratio of the tissue. The experimental results revealed significant site‐ and depth‐dependent variations in recorded parameters. After enzymatic modification of matrix collagen or proteoglycans our results show that collagen primarily controls the dynamic tissue response while proteoglycans affect more the static properties. Experimental measurements in compression and tension suggest a nonlinear compression–tension behavior of articular cartilage in the direction perpendicular to articular surface. Fibril reinforced poroelastic finite element model was used to capture the experimentally found compression–tension nonlinearity of articular cartilage.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biphasic Creep and Stress Relaxation of Articular Cartilage in Compression: Theory and Experiments
Mow, V. C., Kuei, S. C., Lai, W. M., & Armstrong, C. G. (1980) · Journal of Biomechanical Engineering · doi:10.1115/1.3138202 · Cited by 2,444 · cited 2×
“As a next step the isotropic biphasic solution [25,29] could also explain the time dependence of the cartilage mechanical behaviour.”
Fluid transport and mechanical properties of articular cartilage: A review
Mow, V. C., Holmes, M. H., & Michael Lai, W. (1984) · Journal of Biomechanics · doi:10.1016/0021-9290(84)90031-9 · Cited by 1,024 · cited 2×
“The elastic modulus of articular cartilage is typically 0.3–1.5 MPa [2,11,30,32].”
InfluentialA mathematical analysis for indentation tests of articular cartilage
Hayes, W. C., Keer, L. M., Herrmann, G., & Mockros, L. F. (1972) · Journal of Biomechanics · doi:10.1016/0021-9290(72)90010-3 · Cited by 967 · cited 1×
“The first models were isotropic and elastic [9] and could be applied only to characterize the instantaneous or equilibrium responses of cartilage after a stepload application.”
Armstrong, C. G., & Mow, V. C. (1982) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198264010-00013 · Cited by 770 · cited 1×
“The compressive stiffness of cartilage is positively related to GAG concentration and negatively related to the hydration of the tissue [1,14].”
BUCKWALTER, J. A., & MANKIN, H. J. (1997) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199704000-00022 · Cited by 755
Depth‐dependent confined compression modulus of full‐thickness bovine articular cartilage
Schinagl, R. M., Gurskis, D., Chen, A. C., & Sah, R. L. (1997) · Journal of Orthopaedic Research · doi:10.1002/jor.1100150404 · Cited by 646 · cited 1×
“Also a significant depth-dependence in compressive stiffness of cartilage has been revealed [35].”
Contact pressures in the human hip joint measured in vivo.
Hodge, W. A., Fijan, R. S., Carlson, K. L., Burgess, R. G., Harris, W. H., & Mann, R. W. (1986) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.83.9.2879 · Cited by 623 · cited 1×
“during dynamic loads have been measured [10].”
Soltz, M. A., & Ateshian, G. A. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00105-5 · Cited by 504
Biphasic indentation of articular cartilage—I. Theoretical analysis
Mak, A. F., Lai, W. M., & Mow, V. C. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90036-4 · Cited by 478 · cited 1×
“As a next step the isotropic biphasic solution [25,29] could also explain the time dependence of the cartilage mechanical behaviour.”
KEMPSON, G., MUIR, H., POLLARD, C., & TUKE, M. (1973) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(73)90093-7 · Cited by 453 · cited 1×
“It is known that collagen meshwork is predominantly responsible for the tensile and shear properties of the tissue while the proteoglycans are main determinants of the compressive stiffness [14–16].”
Optical and mechanical determination of poisson's ratio of adult bovine humeral articular cartilage
Jurvelin, J. S., Buschmann, M. D., & Hunziker, E. B. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(96)00133-9 · Cited by 344 · cited 2×
“This is the main reason why the dynamic stiffness of cartilage may be 10 to 20 times higher than the intrinsic modulus of the matrix [12].”
Self-citationA Molecular Model of Proteoglycan-Associated Electrostatic Forces in Cartilage Mechanics
Buschmann, M. D., & Grodzinsky, A. J. (1995) · Journal of Biomechanical Engineering · doi:10.1115/1.2796000 · Cited by 331 · cited 1×
“Glycosaminoglycans (GAGs) attract water and repel each other due to their electronegativity, creating a swelling pressure that is restrained by the collagenous meshwork [5–8, 26, 38, 40, Cartilage is functionally highly anisotropic.”
Soltz, M. A., & Ateshian, G. A. (2000) · Journal of Biomechanical Engineering · doi:10.1115/1.1324669 · Cited by 330 · cited 2×
“The nonlinearity suggests for the use of anisotropic models, such as the models presented by Li et al. (1999) [23] or Soltz and Ateshian (2000) [36].”
Kiviranta, I., Jurvelin, J. S., S��m�nen, A.-M., & Helminen, H. J. (1985) · Histochemistry and Cell Biology · doi:10.1007/bf00501401 · Cited by 298 · cited 2×
“Optical density (from safranin O stain) indicates the local PG content in tissue [17,18,21,33]. function.”
Self-citationSwelling of articular cartilage and other connective tissues: Electromechanochemical forces
Eisenberg, S. R., & Grodzinsky, A. J. (1985) · Journal of Orthopaedic Research · doi:10.1002/jor.1100030204 · Cited by 251 · cited 1×
“Glycosaminoglycans (GAGs) attract water and repel each other due to their electronegativity, creating a swelling pressure that is restrained by the collagenous meshwork [5–8,26,38,40,41].”
A Fibril-Network-Reinforced Biphasic Model of Cartilage in Unconfined Compression
Soulhat, J., Buschmann, M. D., & Shirazi-Adl, A. (1999) · Journal of Biomechanical Engineering · doi:10.1115/1.2798330 · Cited by 250 · cited 2×
“Glycosaminoglycans (GAGs) attract water and repel each other due to their electronegativity, creating a swelling pressure that is restrained by the collagenous meshwork [5–8,26,38,40,41].”
Electromechanical and physicochemical properties of connective tissue.
Grodzinsky, A. J. (1983) · PubMed · Cited by 247
Quantitative MR microscopy of enzymatically degraded articular cartilage
Nieminen, M. T., Töyräs, J., Rieppo, J., Hakumäki, J. M., Silvennoinen, J., Helminen, H. J., & Jurvelin, J. S. (2000) · Magnetic Resonance in Medicine · Cited by 245 · cited 1×
“The elastic modulus of articular cartilage is typically 0.3–1.5 MPa [2,11,30,32].”
InfluentialSelf-citationKempson, G. E. (1991) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(91)90270-q · Cited by 200 · cited 1×
“Collagens are proteins that form the fibrillar meshwork providing cartilage with its high tensile stiffness and strength [13,15,31].”
Arokoski, J. P., Hyttinen, M. M., Lapveteläinen, T., Takács, P., Kosztáczky, B., Módis, L., Kovanen, V, & Helminen, H. (1996) · Annals of the Rheumatic Diseases · doi:10.1136/ard.55.4.253 · Cited by 174 · cited 2×
“Birefringence (from polarized light microscopy) indicates the degree of paraller organized collagen fibrils (upper panel) [3,19,27].”
Panula, H. E., Hyttinen, M. M., Arokoski, J. P., Långsjö, T. K., Pelttari, A., Kiviranta, I., & Helminen, H. J. (1998) · Annals of the Rheumatic Diseases · doi:10.1136/ard.57.4.237 · Cited by 144 · cited 2×
“Optical density (from safranin O stain) indicates the local PG content in tissue [17,18,21,33].”
Volumetric changes of articular cartilage during stress relaxation in unconfined compression
Zenobi‐Wong, M., Ponticiello, M. S., Kovanen, V., & Jurvelin, J. S. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00084-1 · Cited by 144
Self-citationFinite Element Formulation of Biphasic Poroviscoelastic Model for Articular Cartilage
Suh, J. F., & Bai, S. G. (1998) · Journal of Biomechanical Engineering · doi:10.1115/1.2798302 · Cited by 129 · cited 1×
“In addition to the isotropic solution, transversely isotropic biphasic [28], poroviscoelastic [39], fibril reinforced poroelastic [38] or conewise linear elasticity biphasic [36] solutions exist to improve the accuracy of the theoretical models to predict the cartilage response.”
Mizrahi, J., Maroudas, A., Lanir, Y., Ziv, I., & Webber, T. J. (1986) · Biorheology · doi:10.3233/bir-1986-23402 · Cited by 126 · cited 1×
“Glycosaminoglycans (GAGs) attract water and repel each other due to their electronegativity, creating a swelling pressure that is restrained by the collagenous meshwork [5–8, 26, 38, 40, Cartilage is functionally highly anisotropic.”
Mechanical properties of articular cartilage elucidated by osmotic loading and ultrasound.
Tepic, S., Macirowski, T., & Mann, R. W. (1983) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.80.11.3331 · Cited by 68 · cited 1×
“Glycosaminoglycans (GAGs) attract water and repel each other due to their electronegativity, creating a swelling pressure that is restrained by the collagenous meshwork [5–8, 26, 38, 40, Cartilage is functionally highly anisotropic.”
Kim, H. Y., & Yasuda, H. K. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(1999)48:2<99::aid-jbm1>3.0.co;2-n · Cited by 54 · cited 1×
“The elastic modulus of articular cartilage is typically 0.3–1.5 MPa [2,11,30,32].”
Influential
Cited by
Moroni, L., de Wijn, J. R., & van Blitterswijk, C. A. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.07.023 · Cited by 534
Strategic Design and Fabrication of Engineered Scaffolds for Articular Cartilage Repair
Izadifar, Z., Chen, X., & Kulyk, W. (2012) · Journal of Functional Biomaterials · doi:10.3390/jfb3040799 · Cited by 203
Nanocellulose-Based Interpenetrating Polymer Network (IPN) Hydrogels for Cartilage Applications
Naseri, N., Deepa, B., Mathew, A. P., Oksman, K., & Girandon, L. (2016) · Biomacromolecules · doi:10.1021/acs.biomac.6b01243 · Cited by 186
Fabrication of a multi-layered decellularized amniotic membranes as tissue engineering constructs
Yüksel, S., Aşık, M. D., Aydin, H. M., Tönük, E., Aydın, E. Y., & Bozkurt, M. (2022) · Tissue and Cell · doi:10.1016/j.tice.2021.101693 · Cited by 6
Metadata
- Authors
- Laasanen, M. S., Töyräs, J., Korhonen, R. K., Rieppo, J., Saarakkala, S., Nieminen, M. T., Hirvonen, J., & Jurvelin, J. S.
- Venue
- Biorheology: The Official Journal of the International Society of Biorheology
- Publisher
- SAGE Publications
- Published
- 2003-01
- Volume
- 40
- Issue
- 1-3
- Pages
- 133-140
- ISSN
- 0006-355X (ISSN-L)
- 1878-5034
- OpenAlex
- W1779199741
- Cited by
- 212
- References
- 26
- FWCI
- 7.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.