Automated biomanipulation of single cells using magnetic microrobots
Open accessThe DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
Transport of individual cells or chemical payloads on a subcellular scale is an enabling tool for the study of cellular communication, cell migration, and other localized phenomena. We present a magnetically actuated robotic system capable of fully automated manipulation of cells and microbeads. Our strategy uses autofluorescent robotic transporters and fluorescently labeled microbeads to aid tracking and control in optically obstructed environments. We demonstrate automated delivery of microbeads infused with chemicals to specified positions on neurons. This system is compatible with standard upright and inverted light microscopes and is capable of applying forces less than 1 pN for precision positioning tasks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Emerging applications of stimuli-responsive polymer materials
Stuart, M. A. C., Huck, W. T. S., Genzer, J., Müller, M., Ober, C., Stamm, M., Sukhorukov, G. B., Szleifer, I., Tsukruk, V. V., Urban, M., et al. (2010) · Nature Materials · doi:10.1038/nmat2614 · Cited by 5,707 · cited 1×
“Furthermore, their design may be specifically tailored for customized time-based release or even release in response to environmental or other external triggers (Suart et al. 2010).”
BackgroundCell Migration: Integrating Signals from Front to Back
Ridley, A. J., Schwartz, M. A., Burridge, K., Firtel, R. A., Ginsberg, M. H., Borisy, G., Parsons, J. T., & Horwitz, A. R. (2003) · Science · doi:10.1126/science.1092053 · Cited by 4,978 · cited 1×
“Molecular gradients are important for various biological processes such as cell migration, differentiation during embryonic morphogenesis, and disease progression in cancer (Ridley et al. 2003).”
BackgroundSingle-molecule force spectroscopy: optical tweezers, magnetic tweezers and atomic force microscopy
Neuman, K. C., & Nagy, A. (2008) · Nature Methods · doi:10.1038/nmeth.1218 · Cited by 2,406 · cited 1×
“It should be noted that the scale of forces applied is comparable to techniques such as atomic force microscopy (AFM) and optical tweezers (Neuman and Nagy 2008).”
MethodMicrorobots for Minimally Invasive Medicine
Nelson, B. J., Kaliakatsos, I. K., & Abbott, J. J. (2010) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-010510-103409 · Cited by 1,968 · cited 1×
“As an alternative approach, tetherless, remotely controlled microrobots have the potential to be used as medical tools for the localized delivery of chemicals, cells and other biological substances in vivo and in vitro (Fernandes and Gracias 2009; Nelson et al. 2010).”
BackgroundMassively parallel manipulation of single cells and microparticles using optical images
Chiou, P. Y., Ohta, A. T., & Wu, M. C. (2005) · Nature · doi:10.1038/nature03831 · Cited by 1,444 · cited 1×
“Single-cell manipulation has traditionally been achieved with pipettes, and more recently with electrical forces, optical traps, or microelectromechanical system (MEMS) devices (Chiou et al. 2005; Voldman 2006; Desai et al. 2007).”
MethodPolymer microspheres for controlled drug release
Freiberg, S., & Zhu, X. X. (2004) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2004.04.013 · Cited by 1,336 · cited 1×
“Encapsulation and transport of chemicals in microbeads has been widely studied, mainly as a technique for the distribution and extended release of pharmaceuticals Freiberg and Zhu (2004).”
BackgroundControlled Propulsion of Artificial Magnetic Nanostructured Propellers
Ghosh, A., & Fischer, P. (2009) · Nano Letters · doi:10.1021/nl900186w · Cited by 1,296 · cited 1×
“Several untethered magnetic microrobots have been developed and employed for micromanipulation tasks (Dauge et al. 2007; Sakar et al. 2010b; Floyd et al. 2009; Leong et al. 2009; Ghosh and Fischer 2009; Frutiger et al. 2010; Zhang et al. 2010; Hagiwara et al. 2011; Tottori et al. 2012).”
MethodMagnetic Helical Micromachines: Fabrication, Controlled Swimming, and Cargo Transport
Tottori, S., Zhang, L., Qiu, F., Krawczyk, K. K., Franco‐Obregón, A., & Nelson, B. J. (2012) · Advanced Materials · doi:10.1002/adma.201103818 · Cited by 1,185 · cited 1×
“Several untethered magnetic microrobots have been developed and employed for micromanipulation tasks (Dauge et al. 2007; Sakar et al. 2010b; Floyd et al. 2009; Leong et al. 2009; Ghosh and Fischer 2009; Frutiger et al. 2010; Zhang et al. 2010; Hagiwara et al. 2011; Tottori et al. 2012).”
MethodOctoMag: An Electromagnetic System for 5-DOF Wireless Micromanipulation
Kummer, M. P., Abbott, J. J., Kratochvil, B. E., Borer, R., Sengul, A., & Nelson, B. J. (2010) · IEEE Transactions on Robotics · doi:10.1109/tro.2010.2073030 · Cited by 1,161
A Class of Algorithms for Fast Digital Image Registration
Barnea, D. I., & Silverman, H. F. (1972) · IEEE Transactions on Computers · doi:10.1109/tc.1972.5008923 · Cited by 977 · cited 1×
“The first winnowing of the field of view is a block matching optical flow estimation that tends to disregard smaller, out of focus moving particles present in the field of view (Barnea and Silverman 1972).”
Background
Cited by
Biomedical Applications of Untethered Mobile Milli/Microrobots
Sitti, M., Ceylan, H., Hu, W., Giltinan, J., Turan, M., Yim, S., & Diller, E. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2014.2385105 · Cited by 893
Magnetically Driven Micro and Nanorobots
Zhou, H., Mayorga-Martinez, C. C., Pané, S., Zhang, L., & Pumera, M. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01234 · Cited by 889
Cellular Cargo Delivery: Toward Assisted Fertilization by Sperm-Carrying Micromotors
Medina-Sánchez, M., Schwarz, L., Meyer, A. K., Hebenstreit, F., & Schmidt, O. G. (2016) · Nano Letters · doi:10.1021/acs.nanolett.5b04221 · Cited by 553
Wang, B., Kostarelos, K., Nelson, B. J., & Zhang, L. (2021) · Advanced Materials · doi:10.1002/adma.202002047 · Cited by 497
Nanomagnetic encoding of shape-morphing micromachines
Cui, J., Huang, T.-Y., Luo, Z., Testa, P., Gu, H., Chen, X.-Z., Nelson, B. J., & Heyderman, L. J. (2019) · Nature · doi:10.1038/s41586-019-1713-2 · Cited by 474
Development of a magnetic microrobot for carrying and delivering targeted cells
Li, J., Li, X., Luo, T., Wang, R., Liu, C., Chen, S., Li, D., Yue, J., Cheng, S.-H., & Sun, D. (2018) · Science Robotics · doi:10.1126/scirobotics.aat8829 · Cited by 463
Ultra-extensible ribbon-like magnetic microswarm
Yu, J., Wang, B., Du, X., Wang, Q., & Zhang, L. (2018) · Nature Communications · doi:10.1038/s41467-018-05749-6 · Cited by 422
Magnetic Actuation Systems for Miniature Robots: A Review
Yang, Z., & Zhang, L. (2020) · Advanced Intelligent Systems · doi:10.1002/aisy.202000082 · Cited by 388
Recent developments in magnetically driven micro- and nanorobots
Chen, X.-Z., Hoop, M., Mushtaq, F., Siringil, E., Hu, C., Nelson, B. J., & Pané, S. (2017) · Applied Materials Today · doi:10.1016/j.apmt.2017.04.006 · Cited by 373
Biomedical Micro‐/Nanomotors: From Overcoming Biological Barriers to In Vivo Imaging
Gao, C., Wang, Y., Ye, Z., Lin, Z., Ma, X., & He, Q. (2021) · Advanced Materials · doi:10.1002/adma.202000512 · Cited by 358
3D steerable, acoustically powered microswimmers for single-particle manipulation
Ren, L., Nama, N., McNeill, J. M., Soto, F., Yan, Z., Liu, W., Wang, W., Wang, J., & Mallouk, T. E. (2019) · Science Advances · doi:10.1126/sciadv.aax3084 · Cited by 302
Medical Imaging of Microrobots: Toward In Vivo Applications
Aziz, A., Pane, S., Iacovacci, V., Koukourakis, N., Czarske, J., Menciassi, A., Medina-Sánchez, M., & Schmidt, O. G. (2020) · ACS Nano · doi:10.1021/acsnano.0c05530 · Cited by 287
Catalytic antimicrobial robots for biofilm eradication
Hwang, G., Paula, A. J., Hunter, E. E., Liu, Y., Babeer, A., Karabucak, B., Stebe, K., Kumar, V., Steager, E., & Koo, H. (2019) · Science Robotics · doi:10.1126/scirobotics.aaw2388 · Cited by 286
“Sensing was achieved via a charge-coupled device camera, which can be used for visual feedback in a closed-loop system (40).”
MethodSelf-citationHuang, T., Sakar, M. S., Mao, A., Petruska, A. J., Qiu, F., Chen, X., Kennedy, S., Mooney, D., & Nelson, B. J. (2015) · Advanced Materials · doi:10.1002/adma.201503095 · Cited by 239
External Power-Driven Microrobotic Swarm: From Fundamental Understanding to Imaging-Guided Delivery
Wang, Q., & Zhang, L. (2021) · ACS Nano · doi:10.1021/acsnano.0c07753 · Cited by 231
Metadata
- Authors
- Steager, E. B., Selman Sakar, M., Magee, C., Kennedy, M., Cowley, A., & Kumar, V.
- Venue
- The International Journal of Robotics Research
- Publisher
- SAGE Publications
- Published
- 2013-03
- Volume
- 32
- Issue
- 3
- Pages
- 346-359
- ISSN
- 0278-3649 (ISSN-L)
- 1741-3176
- OpenAlex
- W2041830411
- Cited by
- 235
- References
- 27
- FWCI
- 11.21
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.