Automated biomanipulation of single cells using magnetic microrobots
Open accessThe DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
Transport of individual cells or chemical payloads on a subcellular scale is an enabling tool for the study of cellular communication, cell migration, and other localized phenomena. We present a magnetically actuated robotic system capable of fully automated manipulation of cells and microbeads. Our strategy uses autofluorescent robotic transporters and fluorescently labeled microbeads to aid tracking and control in optically obstructed environments. We demonstrate automated delivery of microbeads infused with chemicals to specified positions on neurons. This system is compatible with standard upright and inverted light microscopes and is capable of applying forces less than 1 pN for precision positioning tasks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Emerging applications of stimuli-responsive polymer materials
Stuart, M. A. C., Huck, W. T. S., Genzer, J., Müller, M., Ober, C., Stamm, M., Sukhorukov, G. B., Szleifer, I., Tsukruk, V. V., Urban, M., et al. (2010) · Nature Materials · doi:10.1038/nmat2614 · Cited by 5,707 · cited 1×
“Furthermore, their design may be specifically tailored for customized time-based release or even release in response to environmental or other external triggers (Suart et al. 2010).”
BackgroundCell Migration: Integrating Signals from Front to Back
Ridley, A. J., Schwartz, M. A., Burridge, K., Firtel, R. A., Ginsberg, M. H., Borisy, G., Parsons, J. T., & Horwitz, A. R. (2003) · Science · doi:10.1126/science.1092053 · Cited by 4,978 · cited 1×
“Molecular gradients are important for various biological processes such as cell migration, differentiation during embryonic morphogenesis, and disease progression in cancer (Ridley et al. 2003).”
BackgroundSingle-molecule force spectroscopy: optical tweezers, magnetic tweezers and atomic force microscopy
Neuman, K. C., & Nagy, A. (2008) · Nature Methods · doi:10.1038/nmeth.1218 · Cited by 2,406 · cited 1×
“It should be noted that the scale of forces applied is comparable to techniques such as atomic force microscopy (AFM) and optical tweezers (Neuman and Nagy 2008).”
MethodMicrorobots for Minimally Invasive Medicine
Nelson, B. J., Kaliakatsos, I. K., & Abbott, J. J. (2010) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-010510-103409 · Cited by 1,968 · cited 1×
“As an alternative approach, tetherless, remotely controlled microrobots have the potential to be used as medical tools for the localized delivery of chemicals, cells and other biological substances in vivo and in vitro (Fernandes and Gracias 2009; Nelson et al. 2010).”
BackgroundMassively parallel manipulation of single cells and microparticles using optical images
Chiou, P. Y., Ohta, A. T., & Wu, M. C. (2005) · Nature · doi:10.1038/nature03831 · Cited by 1,444 · cited 1×
“Single-cell manipulation has traditionally been achieved with pipettes, and more recently with electrical forces, optical traps, or microelectromechanical system (MEMS) devices (Chiou et al. 2005; Voldman 2006; Desai et al. 2007).”
MethodPolymer microspheres for controlled drug release
Freiberg, S., & Zhu, X. X. (2004) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2004.04.013 · Cited by 1,336 · cited 1×
“Encapsulation and transport of chemicals in microbeads has been widely studied, mainly as a technique for the distribution and extended release of pharmaceuticals Freiberg and Zhu (2004).”
BackgroundControlled Propulsion of Artificial Magnetic Nanostructured Propellers
Ghosh, A., & Fischer, P. (2009) · Nano Letters · doi:10.1021/nl900186w · Cited by 1,296 · cited 1×
“Several untethered magnetic microrobots have been developed and employed for micromanipulation tasks (Dauge et al. 2007; Sakar et al. 2010b; Floyd et al. 2009; Leong et al. 2009; Ghosh and Fischer 2009; Frutiger et al. 2010; Zhang et al. 2010; Hagiwara et al. 2011; Tottori et al. 2012).”
MethodMagnetic Helical Micromachines: Fabrication, Controlled Swimming, and Cargo Transport
Tottori, S., Zhang, L., Qiu, F., Krawczyk, K. K., Franco‐Obregón, A., & Nelson, B. J. (2012) · Advanced Materials · doi:10.1002/adma.201103818 · Cited by 1,185 · cited 1×
“Several untethered magnetic microrobots have been developed and employed for micromanipulation tasks (Dauge et al. 2007; Sakar et al. 2010b; Floyd et al. 2009; Leong et al. 2009; Ghosh and Fischer 2009; Frutiger et al. 2010; Zhang et al. 2010; Hagiwara et al. 2011; Tottori et al. 2012).”
MethodOctoMag: An Electromagnetic System for 5-DOF Wireless Micromanipulation
Kummer, M. P., Abbott, J. J., Kratochvil, B. E., Borer, R., Sengul, A., & Nelson, B. J. (2010) · IEEE Transactions on Robotics · doi:10.1109/tro.2010.2073030 · Cited by 1,161
A Class of Algorithms for Fast Digital Image Registration
Barnea, D. I., & Silverman, H. F. (1972) · IEEE Transactions on Computers · doi:10.1109/tc.1972.5008923 · Cited by 977 · cited 1×
“The first winnowing of the field of view is a block matching optical flow estimation that tends to disregard smaller, out of focus moving particles present in the field of view (Barnea and Silverman 1972).”
BackgroundELECTRICAL FORCES FOR MICROSCALE CELL MANIPULATION
Voldman, J. (2006) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095739 · Cited by 892 · cited 1×
“Single-cell manipulation has traditionally been achieved with pipettes, and more recently with electrical forces, optical traps, or microelectromechanical system (MEMS) devices (Chiou et al. 2005; Voldman 2006; Desai et al. 2007).”
MethodJager, E. W. H., Inganäs, O., & Lundström, I. (2000) · Science · doi:10.1126/science.288.5475.2335 · Cited by 578 · cited 1×
“As the length scales of robotic systems continue to decrease, one of the emerging applications is the manipulation of single biological cells in fluidic environments (Jager et al. 2000).”
BackgroundYesin, K. B., Vollmers, K., & Nelson, B. J. (2006) · The International Journal of Robotics Research · doi:10.1177/0278364906065389 · Cited by 465 · cited 1×
“Once the external field is removed the microrobot will have a magnetization value equal called its remanent magnetization (Yesin et al. 2006).”
BackgroundTetherless thermobiochemically actuated microgrippers
Leong, T. G., Randall, C. L., Benson, B. R., Bassik, N., Stern, G. M., & Gracias, D. H. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0807698106 · Cited by 433 · cited 1×
“Several untethered magnetic microrobots have been developed and employed for micromanipulation tasks (Dauge et al. 2007; Sakar et al. 2010b; Floyd et al. 2009; Leong et al. 2009; Ghosh and Fischer 2009; Frutiger et al. 2010; Zhang et al. 2010; Hagiwara et al. 2011; Tottori et al. 2012).”
MethodRobotics in the Small, Part I: Microbotics
Abbott, J. J., Nagy, Z., Beyeler, F., & Nelson, B. J. (2007) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2007.380641 · Cited by 351 · cited 3×
“One way to avoid demagnetization is to minimize the angle between B and M so that torque will be produced on the microrobot instead of demagnetization (Abbott et al. 2007).”
BackgroundModeling and Experimental Characterization of an Untethered Magnetic Micro-Robot
Pawashe, C., Floyd, S., & Sitti, M. (2009) · The International Journal of Robotics Research · doi:10.1177/0278364909341413 · Cited by 318 · cited 1×
“The robot exhibits a stick–slip motion induced by rocking magnetic fields similar to that reported elsewhere Gauthier and Piat (2004); Pawashe et al. (2009).”
MethodArtificial bacterial flagella for micromanipulation
Zhang, L., Peyer, K. E., & Nelson, B. J. (2010) · Lab on a Chip · doi:10.1039/c004450b · Cited by 318 · cited 1×
“Several untethered magnetic microrobots have been developed and employed for micromanipulation tasks (Dauge et al. 2007; Sakar et al. 2010b; Floyd et al. 2009; Leong et al. 2009; Ghosh and Fischer 2009; Frutiger et al. 2010; Zhang et al. 2010; Hagiwara et al. 2011; Tottori et al. 2012).”
MethodMagnetically actuated propulsion at low Reynolds numbers: towards nanoscale control
Fischer, P., & Ghosh, A. (2011) · Nanoscale · doi:10.1039/c0nr00566e · Cited by 292 · cited 2×
“magnetic resonance imaging) and in biological environments (Fischer and Ghosh 2011).”
BackgroundMethod2012 IEEE International Conference on Robotics and Automation
(2012) · doi:10.1109/icra15123.2012 · Cited by 244
Small, Fast, and Under Control: Wireless Resonant Magnetic Micro-agents
Frutiger, D. R., Vollmers, K., Kratochvil, B. E., & Nelson, B. J. (2010) · The International Journal of Robotics Research · doi:10.1177/0278364909353351 · Cited by 211 · cited 1×
“Several untethered magnetic microrobots have been developed and employed for micromanipulation tasks (Dauge et al. 2007; Sakar et al. 2010b; Floyd et al. 2009; Leong et al. 2009; Ghosh and Fischer 2009; Frutiger et al. 2010; Zhang et al. 2010; Hagiwara et al. 2011; Tottori et al. 2012).”
MethodSingle cell manipulation using ferromagnetic composite microtransporters
Sakar, M. S., Steager, E. B., Kim, D. H., Kim, M. J., Pappas, G. J., & Kumar, V. (2010) · Applied Physics Letters · doi:10.1063/1.3293457 · Cited by 146 · cited 4×
“In our previous work, we developed a single-step fabrication process for biocompatible magnetic microrobots that did not require subsequent lithography or etching processes (Sakar et al. 2010b).”
BackgroundMethodSelf-citationEngineering Approaches to Biomanipulation
Desai, J. P., Pillarisetti, A., & Brooks, A. D. (2007) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.9.060906.151940 · Cited by 146 · cited 1×
“Single-cell manipulation has traditionally been achieved with pipettes, and more recently with electrical forces, optical traps, or microelectromechanical system (MEMS) devices (Chiou et al. 2005; Voldman 2006; Desai et al. 2007).”
MethodBarrett, L. E., Sul, J., Takano, H., Bockstaele, E. J. V., Haydon, P. G., & Eberwine, J. H. (2006) · Nature Methods · doi:10.1038/nmeth885 · Cited by 131 · cited 1×
“Neuron-enriched primary rat hippocampal cultures are plated at 100,000 per milliliter in Neurobasal medium (Invitrogen) with B-27 supplement (Sigma) on poly-Llysine coated 12-mm round coverslips (Barrett et al. 2006).”
MethodHydrogel microrobots actuated by optically generated vapour bubbles
Hu, W., Ishii, K. S., Fan, Q., & Ohta, A. T. (2012) · Lab on a Chip · doi:10.1039/c2lc40483d · Cited by 113 · cited 1×
“A variety of techniques have been explored for the wireless actuation of microrobots (Abbott et al. 2007; Hu et al. 2012).”
BackgroundCell stimulation with optically manipulated microsources
Kress, H., Park, J. G., Mejean, C. O., Forster, J. D., Park, J. Y., Walse, S. S., Zhang, Y., Wu, D., Weiner, O. D., Fahmy, T. M., et al. (2009) · Nature Methods · doi:10.1038/nmeth.1400 · Cited by 107 · cited 1×
“Localized complex molecular gradients can be created at target locations by positioning multiple beads in the same vicinity (Kress et al. 2009).”
BackgroundToward a miniaturized mechanical surgeon
Fernandes, R., & Gracias, D. H. (2009) · Materials Today · doi:10.1016/s1369-7021(09)70272-x · Cited by 94 · cited 1×
“As an alternative approach, tetherless, remotely controlled microrobots have the potential to be used as medical tools for the localized delivery of chemicals, cells and other biological substances in vivo and in vitro (Fernandes and Gracias 2009; Nelson et al. 2010).”
BackgroundBiosensing and actuation for microbiorobots
Sakar, M. S., Steager, E. B., Julius, A. A., Kim, M. J., Kumar, V., & Pappas, G. J. (2010) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2010.5509528 · Cited by 23 · cited 4×
“In our previous work, we developed a single-step fabrication process for biocompatible magnetic microrobots that did not require subsequent lithography or etching processes (Sakar et al. 2010b).”
BackgroundMethodSelf-citation
Cited by
Biomedical Applications of Untethered Mobile Milli/Microrobots
Sitti, M., Ceylan, H., Hu, W., Giltinan, J., Turan, M., Yim, S., & Diller, E. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2014.2385105 · Cited by 893
Magnetically Driven Micro and Nanorobots
Zhou, H., Mayorga-Martinez, C. C., Pané, S., Zhang, L., & Pumera, M. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01234 · Cited by 889
Cellular Cargo Delivery: Toward Assisted Fertilization by Sperm-Carrying Micromotors
Medina-Sánchez, M., Schwarz, L., Meyer, A. K., Hebenstreit, F., & Schmidt, O. G. (2016) · Nano Letters · doi:10.1021/acs.nanolett.5b04221 · Cited by 553
Wang, B., Kostarelos, K., Nelson, B. J., & Zhang, L. (2021) · Advanced Materials · doi:10.1002/adma.202002047 · Cited by 497
Nanomagnetic encoding of shape-morphing micromachines
Cui, J., Huang, T.-Y., Luo, Z., Testa, P., Gu, H., Chen, X.-Z., Nelson, B. J., & Heyderman, L. J. (2019) · Nature · doi:10.1038/s41586-019-1713-2 · Cited by 474
Metadata
- Authors
- Steager, E. B., Selman Sakar, M., Magee, C., Kennedy, M., Cowley, A., & Kumar, V.
- Venue
- The International Journal of Robotics Research
- Publisher
- SAGE Publications
- Published
- 2013-03
- Volume
- 32
- Issue
- 3
- Pages
- 346-359
- ISSN
- 0278-3649 (ISSN-L)
- 1741-3176
- OpenAlex
- W2041830411
- Cited by
- 235
- References
- 27
- FWCI
- 11.21
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.