A biologically inspired soft exosuit for walking assistance
The DOI matches its Crossref record; 65 of the 66 references it cites were found in a registry or an index.
Abstract
We present the design and evaluation of a multi-articular soft exosuit that is portable, fully autonomous, and provides assistive torques to the wearer at the ankle and hip during walking. Traditional rigid exoskeletons can be challenging to perfectly align with a wearer’s biological joints and can have large inertias, which can lead to the wearer altering their natural motion patterns. Exosuits, in comparison, use textiles to create tensile forces over the body in parallel with the muscles, enabling them to be light and not restrict the wearer’s kinematics. We describe the biologically inspired design and function of our exosuit, including a simplified model of the suit’s architecture and its interaction with the body. A key feature of the exosuit is that it can generate forces passively due to the body’s motion, similar to the body’s ligaments and tendons. These passively generated forces can be supplemented by actively contracting Bowden cables using geared electric motors, to create peak forces in the suit of up to 200 N. We define the suit–human series stiffness as an important parameter in the design of the exosuit and measure it on several subjects, and we perform human subjects testing to determine the biomechanical and physiological effects of the suit. Results from a five-subject study showed a minimal effect on gait kinematics and an average best-case metabolic reduction of 6.4%, comparing suit worn unpowered versus powered, during loaded walking with 34.6 kg of carried mass including the exosuit and actuators (2.0 kg on both legs, 10.1 kg total).
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Soft-robotic systems therefore show great potential in medical and wearable applications.[462–464]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [462]
Citations
Cites
Gait Analysis: Normal and Pathological Function
(1992) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1992.03490220101046 · Cited by 3,875
McGeer, T. (1990) · The International Journal of Robotics Research · doi:10.1177/027836499000900206 · Cited by 3,359 · cited 2×
“Finally, both humans and passive dynamic walkers use small amounts of input energy at specific times in the gait cycle during walking (McGeer, 1990; Collins et al., 2005).”
BackgroundEfficient Bipedal Robots Based on Passive-Dynamic Walkers
Collins, S., Ruina, A., Tedrake, R., & Wisse, M. (2005) · Science · doi:10.1126/science.1107799 · Cited by 1,873 · cited 1×
“Finally, both humans and passive dynamic walkers use small amounts of input energy at specific times in the gait cycle during walking (McGeer, 1990; Collins et al., 2005).”
BackgroundLower Extremity Exoskeletons and Active Orthoses: Challenges and State-of-the-Art
Dollar, A. M., & Herr, H. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.915453 · Cited by 1,327 · cited 1×
“Other systems were designed to augment healthy individuals, but these could also be used with impaired individuals for rehabilitation or assistance purposes, perhaps with modifications to their control strategies (Dollar and Herr, 2008; Herr, 2009).”
BackgroundDesign and Evaluation of the LOPES Exoskeleton Robot for Interactive Gait Rehabilitation
Veneman, J. F., Kruidhof, R., Hekman, E. E. G., Ekkelenkamp, R., Van Asseldonk, E. H. F., & van der Kooij, H. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903919 · Cited by 1,280 · cited 1×
“Some exoskeletons are stationary, mounted above treadmills and used to provide gait retraining or rehabilitation for those with disabilities or injuries (Jezernik et al., 2003; Banala et al., 2007; Veneman et al., 2007).”
BackgroundGait Analysis: Normal and Pathological Function
Grant, A. D. (2010) · JAMA · doi:10.1001/jama.2010.1210 · Cited by 1,123
Esquenazi, A., Talaty, M., Packel, A., & Saulino, M. (2012) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0b013e318269d9a3 · Cited by 958 · cited 1×
“Devices in the former category are intended to be used by paralyzed individuals, enabling them to walk when they were previously unable to do so (Ackerman, 2010; Neuhaus et al., 2011; Esquenazi et al., 2012).”
BackgroundDonelan, J. M., Kram, R., & Kuo, A. D. (2002) · Journal of Experimental Biology · doi:10.1242/jeb.205.23.3717 · Cited by 670
The Effects of Adding Mass to the Legs on the Energetics and Biomechanics of Walking
BROWNING, R. C., MODICA, J. R., KRAM, R., & GOSWAMI, A. (2007) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31802b3562 · Cited by 603 · cited 2×
“The distribution of the mass is important as prior biomechanics studies have identified that mass at the foot during walking has a metabolic cost of 7.5% to 8.5% per kg of total added mass, as compared to 1% to 2% for mass at the waist (Rose and Gamble, 2006; Browning et al., 2007).”
BackgroundInfluentialDerivation of formulae used to calculate energy expenditure in man.
Brockway, J. M. (1987) · PubMed · Cited by 585
Research works printed but not linked: 7
- Brockway JM, 1987, Human Nutrition. Clinical Nutrition, 41, 463
- In H, 2011, 2011 IEEE international conference on rehabilitation robotics (ICORR), 1
- Neuhaus PD, 2011, 2011 IEEE international conference on rehabilitation robotics (ICORR), 1
- Quintero H, 2011, 2011 IEEE international conference on rehabilitation robotics (ICORR), 1
- Rose J, 2006, Human Walking
- 10.1155/2009/829219 · doi:10.1155/2009/829219
- Vanoglio F, 2013, XIII congress of Italian Society of Neurorehabilitation
Cited by
Biomedical applications of soft robotics
Cianchetti, M., Laschi, C., Menciassi, A., & Dario, P. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0022-y · Cited by 1,435
A soft robotic exosuit improves walking in patients after stroke
Awad, L. N., Bae, J., O’Donnell, K., De Rossi, S. M. M., Hendron, K., Sloot, L. H., Kudzia, P., Allen, S., Holt, K. G., Ellis, T. D., et al. (2017) · Science Translational Medicine · doi:10.1126/scitranslmed.aai9084 · Cited by 672
Self-citationFlexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Capacitive Soft Strain Sensors via Multicore–Shell Fiber Printing
Frutiger, A., Muth, J. T., Vogt, D. M., Mengüç, Y., Campo, A., Valentine, A. D., Walsh, C. J., & Lewis, J. A. (2015) · Advanced Materials · doi:10.1002/adma.201500072 · Cited by 468
Self-citationSystematic review on wearable lower-limb exoskeletons for gait training in neuromuscular impairments
Rodríguez-Fernández, A., Lobo-Prat, J., & Font-Llagunes, J. M. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00815-5 · Cited by 435
Hegde, C., Su, J., Tan, J. M. R., He, K., Chen, X., & Magdassi, S. (2023) · ACS Nano · doi:10.1021/acsnano.3c04089 · Cited by 384
Assistance magnitude versus metabolic cost reductions for a tethered multiarticular soft exosuit
Quinlivan, B. T., Lee, S., Malcolm, P., Rossi, D. M., Grimmer, M., Siviy, C., Karavas, N., Wagner, D., Asbeck, A., Galiana, I., et al. (2017) · Science Robotics · doi:10.1126/scirobotics.aah4416 · Cited by 370
Self-citationStronger, Smarter, Softer: Next-Generation Wearable Robots
Asbeck, A. T., De Rossi, S. M. M., Galiana, I., Ding, Y., & Walsh, C. J. (2014) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2014.2360283 · Cited by 368
“Our mobile electromechanical system presented in [50] was tested during loaded walking (24.”
BackgroundMethodInfluentialSelf-citationTextile Technology for Soft Robotic and Autonomous Garments
Sanchez, V., Walsh, C. J., & Wood, R. J. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202008278 · Cited by 292
Self-citationA biologically-inspired multi-joint soft exosuit that can reduce the energy cost of loaded walking
Panizzolo, F. A., Galiana, I., Asbeck, A. T., Siviy, C., Schmidt, K., Holt, K. G., & Walsh, C. J. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0150-9 · Cited by 291
“87 Our research group has demonstrated reductions in metabolic cost during load carriage 88 with a tethered soft exosuit [20, 24].”
MethodSelf-citationSoft Robotic Suits: State of the Art, Core Technologies, and Open Challenges
Xiloyannis, M., Alicea, R., Georgarakis, A.-M., Haufe, F. L., Wolf, P., Masia, L., & Riener, R. (2022) · IEEE Transactions on Robotics · doi:10.1109/tro.2021.3084466 · Cited by 225
“experimentally-identified human-suit series stiffness [55], to map a force reference to a desired position of the tendon.”
BackgroundInfluentialEffect of timing of hip extension assistance during loaded walking with a soft exosuit
Ding, Y., Panizzolo, F. A., Siviy, C., Malcolm, P., Galiana, I., Holt, K. G., & Walsh, C. J. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0196-8 · Cited by 249
“Positive accomplishments including reductions in energetic cost of walking, have been achieved in the past 2 years by means of autonomous or tethered systems [5–9, 26–30].”
Self-citationCompliant lower limb exoskeletons: a comprehensive review on mechanical design principles
Sanchez-Villamañan, M. D. C., Gonzalez-Vargas, J., Torricelli, D., Moreno, J. C., & Pons, J. L. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-019-0517-9 · Cited by 224
Mooney, L. M., & Herr, H. M. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0111-3 · Cited by 229
“During level ground walking, the powered exosuit was shown to reduce the metabolic cost of walking when compared to the powered-off exosuit [12].”
ResultPerformance Evaluation of Lower Limb Exoskeletons: A Systematic Review
Pinto-Fernandez, D., Torricelli, D., Sanchez-Villamanan, M. D. C., Aller, F., Mombaur, K., Conti, R., Vitiello, N., Moreno, J. C., & Pons, J. L. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.2989481 · Cited by 220
“12) Weight Bearing: Weight bearing is the fourth most covered motor skill, with 19 publications, [9], [20], [34], [51], [53], [73], [128], [130], [146], [149], [153], [160], [164], [172], [179]–[184].”
Soft Actuators and Robotic Devices for Rehabilitation and Assistance
Pan, M., Yuan, C., Liang, X., Dong, T., Liu, T., Zhang, J., Zou, J., Yang, H., & Bowen, C. (2022) · Advanced Intelligent Systems · doi:10.1002/aisy.202100140 · Cited by 218
Biomechanical and Physiological Evaluation of Multi-Joint Assistance With Soft Exosuits
Ding, Y., Galiana, I., Asbeck, A. T., De Rossi, S. M. M., Bae, J., Santos, T. R. T., de Araujo, V. L., Lee, S., Holt, K. G., & Walsh, C. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2523250 · Cited by 217
“The multi-articular ankle/hip load path, which creates ankle plantarflexion and hip flexion torques on the body with a single actuator as previously reported in [26] and [29], consists of the waist belt and webbing straps that extend from the front of the hip down the sides of the leg to the back of the calf.”
BackgroundInfluentialSelf-citationKim, S., Moore, A., Srinivasan, D., Akanmu, A., Barr, A., Harris-Adamson, C., Rempel, D. M., & Nussbaum, M. A. (2019) · IISE Transactions on Occupational Ergonomics and Human Factors · doi:10.1080/24725838.2018.1561557 · Cited by 189
Thalman, C., & Artemiadis, P. (2020) · Wearable Technologies · doi:10.1017/wtc.2020.4 · Cited by 186
“The interface that attaches the cable to the user must avoid slippage, allow for predictable torque generation when the cable is tensioned, and be comfortable to the wearer (In et al. 2015; Asbeck et al. 2015b).”
BackgroundNäf, M. B., Junius, K., Rossini, M., Rodriguez-Guerrero, C., Vanderborght, B., & Lefeber, D. (2018) · Applied Mechanics Reviews · doi:10.1115/1.4042523 · Cited by 158
Lee, S., Kim, J., Baker, L., Long, A., Karavas, N., Menard, N., Galiana, I., & Walsh, C. J. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0410-y · Cited by 166
Self-citationSoft Pneumatic Actuator Fascicles for High Force and Reliability
Robertson, M. A., Sadeghi, H., Florez, J. M., & Paik, J. (2017) · Soft Robotics · doi:10.1089/soro.2016.0029 · Cited by 159
“As a result of their fundamentally simple construction, SPAs have already been used in a broad range of applications, including rescue robots,(30) rehabilitation,(20,21) bioinspired robotics,(31) and wearable technologies.(16,18,19,32,33) This is due, in part, because they are highly customizable, easy to fabricate, l…”
Yandell, M. B., Quinlivan, B., Popov, D., Walsh, C. J., & Zelik, K. E. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0247-9 · Cited by 161
“The robotic exosuit has been fully detailed in previous work [4, 11, 17] so we only briefly summarize the hard-”
BackgroundMethodResultSelf-citationLamers, E. P., Yang, A., & Zelik, K. E. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2761455 · Cited by 173
“Alternatively, further assistance and versatility might be provided using a portable actuator unit, similar to robotic exosuit hardware that has been developed to assist walking [50], [51].”
Bae, J., Siviy, C., Rouleau, M., Menard, N., Odonnell, K., Geliana, I., Athanassiu, M., Ryan, D., Bibeau, C., Sloot, L., et al. (2018) · 2018 IEEE International Conference on Robotics and Automation (ICRA) · doi:10.1109/icra.2018.8461046 · Cited by 145
“a nonlinear spring with hysteresis that presents different mechanical behaviors in loading and unloading [12], [23].”
BackgroundSelf-citationAcademic Review and Perspectives on Robotic Exoskeletons
Bao, G., Pan, L., Fang, H., Wu, X., Yu, H., Cai, S., Yu, B., & Wan, Y. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2944655 · Cited by 146
Design and development of lower limb exoskeletons: A survey
Aliman, N., Ramli, R., & Haris, S. M. (2017) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2017.05.013 · Cited by 136
The Effect of Hip Assistance Levels on Human Energetic Cost Using Robotic Hip Exoskeletons
Kang, I., Hsu, H., & Young, A. J. (2019) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2019.2890896 · Cited by 135
Yandell, M. B., Tacca, J. R., & Zelik, K. E. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2904924 · Cited by 132
“can affect user performance or comfort if misaligned [14], [41]–[44].”
Multi-joint soft exosuit for gait assistance
Asbeck, A. T., Schmidt, K., Galiana, I., Wagner, D. A., & Walsh, C. J. (2015) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2015.7140069 · Cited by 130
Self-citationLv, G., Zhu, H., & Gregg, R. D. (2018) · IEEE Control Systems · doi:10.1109/mcs.2018.2866605 · Cited by 124
“Soft exosuits [28] by design have low joint impedance, but the control problem becomes substantially more difficult, due to uncertainty in the actuation model from transferring forces to the body through soft, compliant material (rather than a rigid structure).”
Systematic Review on Wearable Lower Extremity Robotic Exoskeletons for Assisted Locomotion
Qiu, S., Pei, Z., Wang, C., & Tang, Z. (2022) · Journal of Bionic Engineering · doi:10.1007/s42235-022-00289-8 · Cited by 131
“The ONYX, a LEEX that counteracts excessive pressure on the back and legs, is ideal for military and first responders with an electromechanical knee actuator, a full set of sensors and an AI computer that understands the user's movements and provides the right torque to assist in climbing steep slopes, lifting or drag…”
BackgroundMethodInfluentialIMU-based iterative control for hip extension assistance with a soft exosuit
Ding, Y., Galiana, I., Siviy, C., Panizzolo, F. A., & Walsh, C. J. (2016) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2016.7487530 · Cited by 115
“The suit-human stiffness is one deciding factor of system efficiency, maximum actuator speed and system actuator profile [42, 43].”
BackgroundSelf-citationMulti-modal control scheme for rehabilitation robotic exoskeletons
Li, X., Pan, Y., Chen, G., & Yu, H. (2017) · The International Journal of Robotics Research · doi:10.1177/0278364917691111 · Cited by 112
Young, A. J., Foss, J., Gannon, H., & Ferris, D. P. (2017) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2017.00004 · Cited by 113
“Numerous industry and research groups are designing exoskeletons that include actuated hip joints (Arazpour et al., 2014; Farris et al., 2014; Giovacchini et al., 2014; Asbeck et al., 2015).”
BackgroundBiomechanical Design of a Novel Flexible Exoskeleton for Lower Extremities
Lee, Y., Kim, Y.-J., Lee, J., Lee, M., Choi, B., Kim, J., Park, Y. J., & Choi, J. (2017) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2017.2718999 · Cited by 110
“Recently, a team at Harvard University introduced a soft exosuit to which they applied the technology of soft robotics [11]– [13].”
BackgroundInfluentialSoft Exoskeletons: Development, Requirements, and Challenges of the Last Decade
Pérez-Vidal, A. F., Morales, J. Y. R., Ortíz-Torres, G., Sorcia‐Vázquez, F. D. J., Rojas, A. C., Mendoza, J. A. B., & Rodríguez-Cerda, J. C. (2021) · Actuators · doi:10.3390/act10070166 · Cited by 108
“Various devices have been developed to provide the power required for standing [26], walking [27], or lifting [28,29].”
BackgroundA soft exosuit for patients with stroke: Feasibility study with a mobile off-board actuation unit
Bae, J., Maria De Rossi, S. M., O'Donnell, K., Hendron, K. L., Awad, L. N., Teles Dos Santos, T. R., De Araujo, V. L., Ding, Y., Holt, K. G., Ellis, T. D., et al. (2015) · 2015 IEEE International Conference on Rehabilitation Robotics (ICORR) · doi:10.1109/icorr.2015.7281188 · Cited by 99
“The PF suit module was adapted from previous multi-articular exosuits described in [18]–[20].”
BackgroundMethodInfluentialSelf-citationControlling negative and positive power at the ankle with a soft exosuit
Lee, S., Crea, S., Malcolm, P., Galiana, I., Asbeck, A. T., & Walsh, C. J. (2016) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2016.7487531 · Cited by 102
“as the actuator pulls the cable further, Fc will also increase in reaction to the tensioning due to the effective human-suit stiffness that is a combination of the suit and the wearer’s body as previously described in [18]; thus, Fc can be explained as an increasing function with respect to xc.”
BackgroundMethodSelf-citationModelling and design of a synergy-based actuator for a tendon-driven soft robotic glove
Xiloyannis, M., Cappello, L., Dinh, B. K., Yen, S., & Masia, L. (2016) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2016.7523796 · Cited by 106
“The latter strategy has been successfully employed in lower-limb assistive exoskeletons: in [9] a bowden-cable transmission allows to locate the actuation unit away from the end-effector and torques are applied to the joints by retracting a set of tendons.”
MethodXiloyannis, M., Cappello, L., Dinh, B. K., Antuvan, C. W., & Masia, L. (2017) · Journal of Rehabilitation and Assistive Technologies Engineering · doi:10.1177/2055668316680315 · Cited by 108
Design and Evaluation of a Bowden-Cable-Based Remote Actuation System for Wearable Robotics
Hofmann, U., Bützer, T., Lambercy, O., & Gassert, R. (2018) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2018.2809625 · Cited by 100
“In [33] a Bowdencable-based RAS for the use in a soft robotic exosuit for walking assistance was presented and output forces of up to 234 N were reported.”
MethodBio-inspired upper limb soft exoskeleton to reduce stroke-induced complications
Li, N., Yang, T., Yu, P., Chang, J., Zhao, L., Zhao, X., Elhajj, I. H., Xi, N., & Liu, L. (2018) · Bioinspiration & Biomimetics · doi:10.1088/1748-3190/aad8d4 · Cited by 92
“First, the human motion model was analysed based on the human anatomy and sports biomechanics [30].”
BackgroundMethodOverview: Types of Lower Limb Exoskeletons
Pamungkas, D. S., Caesarendra, W., Soebakti, H., Analia, R., & Susanto, S. (2019) · Electronics · doi:10.3390/electronics8111283 · Cited by 97
“12 Knee soft exosuit/Harvard University [28] Ankle 1 Active flexion–dorsiflexion DC motor 12.”
BackgroundInfluentialRajappan, A., Jumet, B., Shveda, R. A., Decker, C. J., Liu, Z., Yap, T. F., Sanchez, V., & Preston, D. J. (2022) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2202118119 · Cited by 91
Payne, C. J., Wamala, I., Abah, C., Thalhofer, T., Saeed, M. Y., Bautista‐Salinas, D., Horvath, M. A., Vasilyev, N. V., Roche, E. T., Pigula, F. A., et al. (2017) · Soft Robotics · doi:10.1089/soro.2016.0076 · Cited by 90
“Examples of this approach include soft exosuits 8,9 and rehabilitative devices.”
Self-citationDurandau, G., Rampeltshammer, W. F., van der Kooij, H., & Sartori, M. (2022) · IEEE Transactions on Robotics · doi:10.1109/tro.2022.3170239 · Cited by 87
“by relying on a finite set of pre-computed torque, angle profiles [4], [8]–[12] or a priori chosen neuromuscular reflexive rules [13], [14] triggered at pre-determined gait events.”
BackgroundMethodHussain, F., Goecke, R., & Mohammadian, M. (2021) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/09544119211032010 · Cited by 86
Review of Research and Development of Supernumerary Robotic Limbs
Tong, Y., & Liu, J. (2021) · IEEE/CAA Journal of Automatica Sinica · doi:10.1109/jas.2021.1003961 · Cited by 89
Virtual Performance Augmentation in an Immersive Jump & Run Exergame
Ioannou, C., Archard, P., O'Neill, E. J., & Lutteroth, C. (2019) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/3290605.3300388 · Cited by 94
“The idea of augmenting human physical, mental and social capabilities has intrigued scientists from many disciplines [94] and led, for example, to the development of powered exoskeletons [5, 33, 131].”
BackgroundWearable Assistive Robotics: A Perspective on Current Challenges and Future Trends
Martínez-Hernández, U., Metcalfe, B., Assaf, T., Jabban, L., Male, J., & Zhang, D. (2021) · Sensors · doi:10.3390/s21206751 · Cited by 90
Soft robotic ventricular assist device with septal bracing for therapy of heart failure
Payne, C. J., Wamala, I., Bautista‐Salinas, D., Saeed, M. Y., Story, D. V., Thalhofer, T., Horvath, M. A., Abah, C., del Nido, P. J., Walsh, C. J., et al. (2017) · Science Robotics · doi:10.1126/scirobotics.aan6736 · Cited by 84
Self-citationChallenges and solutions for application and wider adoption of wearable robots
Babič, J., Laffranchi, M., Tessari, F., Verstraten, T., Novak, D., Šarabon, N., Uğurlu, B., Peternel, L., Torricelli, D., & Veneman, J. F. (2021) · Wearable Technologies · doi:10.1017/wtc.2021.13 · Cited by 84
“In portable devices, these transmissions can decrease metabolic cost by enabling a more proximal placement of the actuators, near the human’s center of mass (Asbeck et al., 2015).”
BackgroundExperimental Evaluation of Energy Efficiency for a Soft Wearable Robotic Suit
Jin, S., IWAMOTO, N., Hashimoto, K., & Yamamoto, M. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2613886 · Cited by 85
Young, A. J., Gannon, H., & Ferris, D. P. (2017) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2017.00037 · Cited by 77
“, 2015; Mooney and Herr, 2016) and hip exoskeletons (Asbeck et al., 2015; Seo et al., 2016).”
BackgroundLerner, Z. F., Damiano, D. L., & Bulea, T. C. (2017) · Scientific Reports · doi:10.1038/s41598-017-13554-2 · Cited by 78
Underactuated Soft Hip Exosuit Based on Adaptive Oscillators to Assist Human Locomotion
Tricomi, E., Lotti, N., Missiroli, F., Zhang, X., Xiloyannis, M., Muller, T., Crea, S., Papp, E., Krzywinski, J., Vitiello, N., et al. (2021) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2021.3136240 · Cited by 80
“In addition, design compactness makes the system comfortable to the user that does not need to wear backpack-like hulking components similarly to most of the current existing solutions [5], [24].”
BackgroundStroke Rehabilitation: Therapy Robots and Assistive Devices
Klamroth-Marganska, V. (2018) · Advances in experimental medicine and biology · doi:10.1007/978-3-319-77932-4_35 · Cited by 79
A Review of Soft Actuator Motion: Actuation, Design, Manufacturing and Applications
Tang, X., Li, H., Ma, T., Yang, Y., Luo, J. R., Wang, H., & Jiang, P. (2022) · Actuators · doi:10.3390/act11110331 · Cited by 82
Exoskeleton-Assisted Rehabilitation and Neuroplasticity in Spinal Cord Injury
Ya-na, H., Xu, Y., Hai, M., Yang, F. E. N. G., Liu, P., Chen, Z., & Duan, W. (2024) · World Neurosurgery · doi:10.1016/j.wneu.2024.01.167 · Cited by 79
Biomechanical models in the lower-limb exoskeletons development: a review
Firouzi, V., Andre Seyfarth, A., Song, S., von Stryk, O., & Sharbafi, M. A. (2025) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-025-01556-5 · Cited by 72
Park, D., & Cho, K. (2017) · PLoS ONE · doi:10.1371/journal.pone.0173730 · Cited by 77
Dunkelberger, N., Schearer, E. M., & O’Malley, M. K. (2020) · Experimental Neurology · doi:10.1016/j.expneurol.2020.113274 · Cited by 73
A Lower Limb Exoskeleton With Rigid and Soft Structure for Loaded Walking Assistance
Cao, W., Chen, C., Wang, D., Wu, X., Chen, L., Xu, T., & Liu, J. (2021) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2021.3125723 · Cited by 69
Grimmer, M., Quinlivan, B., Lee, S., Malcolm, P., Rossi, D. M., Siviy, C., & Walsh, C. J. (2018) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2018.11.023 · Cited by 69
Self-citationLi, Z., Li, Q., Huang, P., Xia, H., & Li, G. (2023) · IEEE Transactions on Cybernetics · doi:10.1109/tcyb.2023.3240231 · Cited by 67
“In [14], the suit-human series stiffness was characterized through experiments with several subjects.”
BackgroundDevelopment of a sEMG-based torque estimation control strategy for a soft elbow exoskeleton
Lu, L., Wu, Q., Chen, X., Shao, Z., Chen, B., & Wu, H. (2018) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2018.10.017 · Cited by 67
A survey on soft lower limb cable-driven wearable robots without rigid links and joints
Mahmoudi, A., & Najafi, F. (2021) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2021.103846 · Cited by 71
A Reconfigurable Pneumatic Bending Actuator with Replaceable Inflation Modules
Natividad, R. F., Rosario, M. D., Chen, P. C. Y., & Yeow, C. (2018) · Soft Robotics · doi:10.1089/soro.2017.0064 · Cited by 64
“17,18 Tendon-based systems require the precise positioning of its anchor points to be effective 19,20 and, thus, add further complications to the adaptation of the system.”
Wang, L., Nurzaman, S. G., & Iida, F. (2017) · doi:10.1561/9781680832655 · Cited by 62
Soft Wearable Robots: Development Status and Technical Challenges
Shi, Y., Dong, W., Lin, W., & Gao, Y. (2022) · Sensors · doi:10.3390/s22197584 · Cited by 67
“In [95,96], a portable prototype combined the suit composed of multiple webbings with Bowden cables extending from the pelvis to the heel, which achieved the synthesis of passive and active assistance.”
BackgroundMethodVarying negative work assistance at the ankle with a soft exosuit during loaded walking
Malcolm, P., Lee, S., Crea, S., Siviy, C., Saucedo, F., Galiana, I., Panizzolo, F. A., Holt, K. G., & Walsh, C. J. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0267-5 · Cited by 61
Self-citationAutonomous Multi-Joint Soft Exosuit for Assistance with Walking Overground
Lee, S., Karavas, N. C., Quinlivan, B. T., LouiseRyan, D., Perry, D., Eckert-Erdheim, A. M., Murphy, P., Goldy, T. G., Menard, N., Athanassiu, M., et al. (2018) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2018.8460972 · Cited by 61
“Following the trend of wearable devices targeting specific joint motions with lightweight components, our group has been using functional apparel to comfortably anchor to the body and deliver assistance to specific target joints, creating “soft exosuits” [12-20].”
BackgroundMethodSelf-citationDesign and development of a lightweight ankle exoskeleton for human walking augmentation
Bougrinat, Y., Achiche, S., & Raison, M. (2019) · Mechatronics · doi:10.1016/j.mechatronics.2019.102297 · Cited by 67
Reyes, F. A., Thangavel, P., & Yu, H. (2018) · International Journal of Intelligent Robotics and Applications · doi:10.1007/s41315-017-0042-6 · Cited by 59
“Also “soft robotics” that are fabricated with polymeric elastomers and claims to be portable, self-directed, lightweight and with sufficient torque-generating capability to apply biologically relevant forces to the lower limb joints of the wearer (Asbeck et al. 2015), may give a solution.”
BackgroundKim, J., Heimgartner, R., Lee, G., Karavas, N. C., Perry, D., Ryan, D. L., Eckert-Erdheim, A. M., Murphy, P., Choe, D. K., Galiana, I., et al. (2018) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2018.8460474 · Cited by 66
Self-citationYandell, M. B., Ziemnicki, D. M., McDonald, K. A., & Zelik, K. E. (2020) · PLoS ONE · doi:10.1371/journal.pone.0228536 · Cited by 58
“User comfort is commonly stated in prior literature to be an important aspect of exosuit and exoskeleton design [1], [8].”
BackgroundMethodInfluentialEvaluating physiological signal salience for estimating metabolic energy cost from wearable sensors
Ingraham, K. A., Ferris, D. P., & Remy, C. D. (2019) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00714.2018 · Cited by 64
Shape memory alloy actuator-embedded smart clothes for ankle assistance
Kim, C., Kim, G., Lee, Y., Lee, G., Han, S., Kang, D., Koo, S. H., & Koh, J. (2020) · Smart Materials and Structures · doi:10.1088/1361-665x/ab78b5 · Cited by 62
“For an assistive device, an important design parameter is the activation timing: the exertion of force with improper timing leads to disturbances in the muscles [7].”
BackgroundMoltedo, M., Baček, T., Verstraten, T., Rodriguez‐Guerrero, C., Vanderborght, B., & Lefeber, D. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0424-5 · Cited by 56
Wu, Q., Chen, B., & Wu, H. (2019) · Mechatronics · doi:10.1016/j.mechatronics.2019.102279 · Cited by 62
Zhang, Q., Lambeth, K., Sun, Z., Dodson, A., Bao, X., & Sharma, N. (2023) · IEEE Transactions on Robotics · doi:10.1109/tro.2023.3236958 · Cited by 55
“Controllers in these robotic devices predominantly provide a priori defined torque/angle profiles [7], [10], [16], [17], [18], while some use neuromuscular reflexive rules [5], [19] that are event-triggered during different gait phases.”
BackgroundKoller, J. R., Remy, C. D., & Ferris, D. P. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0379-6 · Cited by 54
Design on the Bowden Cable-Driven Upper Limb Soft Exoskeleton
Wei, W., Qu, Z., Wang, W., Zhang, P., & Hao, F. (2018) · Applied Bionics and Biomechanics · doi:10.1155/2018/1925694 · Cited by 54
Reliability analysis of a tendon-driven actuation for soft robots
Jeong, U., Kim, K., Kim, S.-H., Choi, H., Youn, B. D., & Cho, K. (2020) · The International Journal of Robotics Research · doi:10.1177/0278364920907151 · Cited by 58
“Some research has been conducted to reduce the frictional effect in the control system of a Bowden cable by using feedforward compensation (Jeong and Cho, 2015, 2017, 2019; Palli and Melchiorri, 2006) or feedback control (Asbeck et al., 2015; Kong et al., 2013; Veneman et al., 2006; Witte et al., 2015).”
InfluentialBryan, G. M., Franks, P. W., Song, S., Reyes, R., O’Donovan, M. P., Gregorczyk, K. N., & Collins, S. H. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00955-8 · Cited by 53
“Many of the devices that have reduced the metabolic cost of loaded walking have assisted hip extension [6, 7], ankle plantarflexion [8–11], hip flexion and ankle plantarflexion [12, 13] or hip flexion, hip extension, and ankle plantarflexion [5, 7].”
BackgroundZhang, Y.-H., Lee, A., & Lee, C.-H. (2024) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2024.115207 · Cited by 55
Thakur, C., Ogawa, K., Tsuji, T., & Kurita, Y. (2018) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2018.2864355 · Cited by 52
“A biologically inspired soft exosuit for walking assistance [12] showed an average metabolic reduction of 5.”
Towards Online Estimation of Human Joint Muscular Torque with a Lower Limb Exoskeleton Robot
Li, M., Deng, J., Zha, F., Qiu, S., Wang, X., & Chen, F. (2018) · Applied Sciences · doi:10.3390/app8091610 · Cited by 52
“For an intention-based, active, power-assist exoskeleton, such as the Hybrid Assistive Limb (HAL) [10] from Tsukuba University and the Soft Exosuit [4] form Harvard University, a estimation of human effort is required by the controller to actively generate and exert assistive force/torque onto the human body.”
Wearable Robotics for Upper-Limb Rehabilitation and Assistance
Varghese, R. J., Freer, D., Deligianni, F., Liu, J., & Yang, G. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-811810-8.00003-8 · Cited by 59
Reducing the metabolic energy of walking and running using an unpowered hip exoskeleton
Zhou, T., Xiong, C., Zhang, J., Hu, D., Chen, W., & Huang, X. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00893-5 · Cited by 51
Nakayama, R., Suzuki, R., Nakamaru, S., Niiyama, R., Kawahara, Y., & Kakehi, Y. (2019) · Designing Interactive Systems Conference · doi:10.1145/3322276.3322337 · Cited by 55
Soft Rehabilitation and Nursing-Care Robots: A Review and Future Outlook
Peng, Z., & Huang, J. (2019) · Applied Sciences · doi:10.3390/app9153102 · Cited by 54
“Previous exosuits generated assistive force by contracting Bolton cables and changed the position of linear actuators [42,43,45] according to the instructions of position controllers.”
MethodIntegration, Sensing, and Control of a Modular Soft-Rigid Pneumatic Lower Limb Exoskeleton
Wang, J., Fei, Y., & Chen, W. (2019) · Soft Robotics · doi:10.1089/soro.2019.0023 · Cited by 50
“13 Two mainstream con-figurations of the soft exoskeletons are the tendon-driven exoskeletons (TDEs) 8 and the bending-driven exoskeletons (BDEs), 14 differentiated by their soft actuators.”
Bessler, J., Prange-Lasonder, G. B., Schulte, R. V., Schaake, L., Prinsen, E. C., & Buurke, J. H. (2020) · Frontiers in Robotics and AI · doi:10.3389/frobt.2020.557606 · Cited by 53
Junius, K., Moltedo, M., Cherelle, P., Rodriguez‐Guerrero, C., Vanderborght, B., & Lefeber, D. (2017) · Bioinspiration & Biomimetics · doi:10.1088/1748-3190/aa806e · Cited by 49
“Inducing beneficial metabolic effects is the result of a complex balance between providing sufficient assistance, at the right time, and adding too much mass to the wearer [96, 127, 128].”
BackgroundMethodInfluentialScherb, D., Wartzack, S. J., & Miehling, J. (2023) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2022.1044275 · Cited by 48
“Other contributions even report a power loss of 50% of the provided energy (Asbeck et al., 2015).”
BackgroundVeale, A. J., Staman, K., & van der Kooij, H. (2020) · Soft Robotics · doi:10.1089/soro.2019.0076 · Cited by 48
“Normal compression and shear interaction forces 34 and breathability 35 are to be optimized for comfort.”
Iterative Learning Control for a Soft Exoskeleton with Hip and Knee Joint Assistance
Chen, C., Zhang, Y., Li, Y., Wang, Z., Liu, Y., Cao, W., & Wu, X. (2020) · Sensors · doi:10.3390/s20154333 · Cited by 48
Dittli, J., Hofmann, U., Bützer, T., Smit, G., Lambercy, O., & Gassert, R. (2021) · Frontiers in Robotics and AI · doi:10.3389/frobt.2020.596185 · Cited by 53
“Actuation units of cable-based transmission systems are mostly composed of rotational electromagnetic motors in combination with gears (Veneman et al., 2007; Asbeck et al., 2015; Nycz et al., 2015; Xiloyannis et al., 2016, 2019; Blumenschein et al., 2017; Park et al., 2019; Rose and O’Malley, 2019), pulleys (Vitiello…”
BackgroundMethodInfluential
Metadata
- Authors
- Asbeck, A. T., De Rossi, S. M. M., Holt, K. G., & Walsh, C. J.
- Affiliations
- Harvard University (US)
- Harvard University, Cambridge, MA, USA
- Boston University (US)
- Venue
- The International Journal of Robotics Research
- Publisher
- SAGE Publications
- Published
- 2015-03-16
- Volume
- 34
- Issue
- 6
- Pages
- 744-762
- ISSN
- 0278-3649 (ISSN-L)
- 1741-3176
- OpenAlex
- W2169410184
- Semantic Scholar
- 6f5747b1e1a55a0b7c475d4d70e90e139f3e74d5
- Cited by
- 450
- References
- 66
- Citations by year
- 2026: 34 · 2025: 43 · 2024: 38 · 2023: 40 · 2022: 39 · 2021: 63 · 2020: 48 · 2019: 43 · 2018: 42 · 2017: 33 · 2016: 21 · 2015: 4
- FWCI
- 16.58
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- The International Journal of Robotics Research (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- soft exosuit, gait assistance, biologically inspired design, energy cost of walking, loaded walking, gait kinematics, wearable robotics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.