The DOI matches its Crossref record; 65 of the 66 references it cites were found in a registry or an index.
A biologically inspired soft exosuit for walking assistance
Abstract
We present the design and evaluation of a multi-articular soft exosuit that is portable, fully autonomous, and provides assistive torques to the wearer at the ankle and hip during walking. Traditional rigid exoskeletons can be challenging to perfectly align with a wearer’s biological joints and can have large inertias, which can lead to the wearer altering their natural motion patterns. Exosuits, in comparison, use textiles to create tensile forces over the body in parallel with the muscles, enabling them to be light and not restrict the wearer’s kinematics. We describe the biologically inspired design and function of our exosuit, including a simplified model of the suit’s architecture and its interaction with the body. A key feature of the exosuit is that it can generate forces passively due to the body’s motion, similar to the body’s ligaments and tendons. These passively generated forces can be supplemented by actively contracting Bowden cables using geared electric motors, to create peak forces in the suit of up to 200 N. We define the suit–human series stiffness as an important parameter in the design of the exosuit and measure it on several subjects, and we perform human subjects testing to determine the biomechanical and physiological effects of the suit. Results from a five-subject study showed a minimal effect on gait kinematics and an average best-case metabolic reduction of 6.4%, comparing suit worn unpowered versus powered, during loaded walking with 34.6 kg of carried mass including the exosuit and actuators (2.0 kg on both legs, 10.1 kg total).
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Soft-robotic systems therefore show great potential in medical and wearable applications.[462–464]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [462]
Citations
Cites
Gait Analysis: Normal and Pathological Function
(1992) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1992.03490220101046 · Cited by 3,875
McGeer, T. (1990) · The International Journal of Robotics Research · doi:10.1177/027836499000900206 · Cited by 3,359 · cited 2×
“Finally, both humans and passive dynamic walkers use small amounts of input energy at specific times in the gait cycle during walking (McGeer, 1990; Collins et al., 2005).”
BackgroundEfficient Bipedal Robots Based on Passive-Dynamic Walkers
Collins, S., Ruina, A., Tedrake, R., & Wisse, M. (2005) · Science · doi:10.1126/science.1107799 · Cited by 1,873 · cited 1×
“Finally, both humans and passive dynamic walkers use small amounts of input energy at specific times in the gait cycle during walking (McGeer, 1990; Collins et al., 2005).”
BackgroundLower Extremity Exoskeletons and Active Orthoses: Challenges and State-of-the-Art
Dollar, A. M., & Herr, H. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.915453 · Cited by 1,327 · cited 1×
“Other systems were designed to augment healthy individuals, but these could also be used with impaired individuals for rehabilitation or assistance purposes, perhaps with modifications to their control strategies (Dollar and Herr, 2008; Herr, 2009).”
BackgroundDesign and Evaluation of the LOPES Exoskeleton Robot for Interactive Gait Rehabilitation
Veneman, J. F., Kruidhof, R., Hekman, E. E. G., Ekkelenkamp, R., Van Asseldonk, E. H. F., & van der Kooij, H. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903919 · Cited by 1,280 · cited 1×
“Some exoskeletons are stationary, mounted above treadmills and used to provide gait retraining or rehabilitation for those with disabilities or injuries (Jezernik et al., 2003; Banala et al., 2007; Veneman et al., 2007).”
BackgroundGait Analysis: Normal and Pathological Function
Grant, A. D. (2010) · JAMA · doi:10.1001/jama.2010.1210 · Cited by 1,123
Esquenazi, A., Talaty, M., Packel, A., & Saulino, M. (2012) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0b013e318269d9a3 · Cited by 958 · cited 1×
“Devices in the former category are intended to be used by paralyzed individuals, enabling them to walk when they were previously unable to do so (Ackerman, 2010; Neuhaus et al., 2011; Esquenazi et al., 2012).”
BackgroundDonelan, J. M., Kram, R., & Kuo, A. D. (2002) · Journal of Experimental Biology · doi:10.1242/jeb.205.23.3717 · Cited by 670
The Effects of Adding Mass to the Legs on the Energetics and Biomechanics of Walking
BROWNING, R. C., MODICA, J. R., KRAM, R., & GOSWAMI, A. (2007) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31802b3562 · Cited by 603 · cited 2×
“The distribution of the mass is important as prior biomechanics studies have identified that mass at the foot during walking has a metabolic cost of 7.5% to 8.5% per kg of total added mass, as compared to 1% to 2% for mass at the waist (Rose and Gamble, 2006; Browning et al., 2007).”
BackgroundInfluentialDerivation of formulae used to calculate energy expenditure in man.
Brockway, J. M. (1987) · PubMed · Cited by 585
The RoboKnee: an exoskeleton for enhancing strength and endurance during walking
Pratt, J. E., Krupp, B. T., Morse, C. J., & Collins, S. H. (2004) · IEEE International Conference on Robotics and Automation, 2004. Proceedings. ICRA '04. 2004 · doi:10.1109/robot.2004.1307425 · Cited by 567 · cited 2×
“These include exoskeletons that aim to help people walk while expending less energy (Kawamoto et al., 2003; Pratt et al., 2004; Ferris and Lewis, 2009; Sawicki and Ferris, 2009a,b; Strausser and Kazerooni, 2011), and those that assist with heavy lifting (Yamamoto et al., 2003; Wehner et al., 2009).”
BackgroundRobotic Orthosis Lokomat: a rehabilitation and research tool
Jezernik, S., Colombo, G., Keller, T., Frueh, H., & Morari, M. (2003) · Neuromodulation Technology at the Neural Interface · doi:10.1046/j.1525-1403.2003.03017.x · Cited by 503 · cited 1×
“Some exoskeletons are stationary, mounted above treadmills and used to provide gait retraining or rehabilitation for those with disabilities or injuries (Jezernik et al., 2003; Banala et al., 2007; Veneman et al., 2007).”
BackgroundExoskeletons and orthoses: classification, design challenges and future directions
Herr, H. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-21 · Cited by 477
Autonomous exoskeleton reduces metabolic cost of human walking during load carriage
Mooney, L. M., Rouse, E. J., & Herr, H. M. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-80 · Cited by 461 · cited 2×
“One mobile ankle exoskeleton (Mooney et al., 2014) has achieved a net metabolic reduction during walking at 1.”
BackgroundInfluentialA Simple Exoskeleton That Assists Plantarflexion Can Reduce the Metabolic Cost of Human Walking
Malcolm, P., Derave, W., Galle, S., & De Clercq, D. (2013) · PLoS ONE · doi:10.1371/journal.pone.0056137 · Cited by 428 · cited 1×
“Two tethered devices have been shown to reduce the metabolic cost of walking, with one (Sawicki and Ferris, 2009b) showing a statistically significant reduction only at 1.75 m/s out of several speeds tested, and another helping at 1.38 m/s (Malcolm et al., 2013).”
BackgroundInfluentialA QUASI-PASSIVE LEG EXOSKELETON FOR LOAD-CARRYING AUGMENTATION
WALSH, C. J., ENDO, K., & HERR, H. (2007) · International Journal of Humanoid Robotics · doi:10.1142/s0219843607001126 · Cited by 427 · cited 2×
“These devices off-load the wearer, bypassing their musculature (Garcia et al., 2002; Kazerooni and Steger, 2006; Walsh et al., 2007).”
BackgroundSelf-citationPower assist method for HAL-3 using EMG-based feedback controller
Kawamoto, H., Lee, S., Kanbe, S., & Sankai, Y. (2004) · SMC'03 Conference Proceedings. 2003 IEEE International Conference on Systems, Man and Cybernetics. Conference Theme - System Security and Assurance (Cat. No.03CH37483) · doi:10.1109/icsmc.2003.1244649 · Cited by 392 · cited 2×
“These include exoskeletons that aim to help people walk while expending less energy (Kawamoto et al., 2003; Pratt et al., 2004; Ferris and Lewis, 2009; Sawicki and Ferris, 2009a,b; Strausser and Kazerooni, 2011), and those that assist with heavy lifting (Yamamoto et al., 2003; Wehner et al., 2009).”
BackgroundElastic energy storage in tendons: mechanical differences related to function and age
Shadwick, R. E. (1990) · Journal of Applied Physiology · doi:10.1152/jappl.1990.68.3.1033 · Cited by 362 · cited 2×
“(Shadwick, 1990; Finni et al., 2013), which means that energy must be added to the suit as it relaxes to duplicate the behavior of muscles and tendons.”
BackgroundResultA lightweight soft exosuit for gait assistance
Wehner, M., Quinlivan, B., Aubin, P. M., Martinez-Villalpando, E., Baumann, M., Stirling, L., Holt, K., Wood, R., & Walsh, C. (2013) · 2013 IEEE International Conference on Robotics and Automation · doi:10.1109/icra.2013.6631046 · Cited by 361 · cited 1×
“Looking to create a wearable robot that implements these features, we have recently proposed a new paradigm in assistive device design, namely soft clothing-like ‘‘exosuits’’ (Asbeck et al., 2013; Wehner et al., 2013).”
BackgroundSelf-citationActive Leg Exoskeleton (ALEX) for Gait Rehabilitation of Motor-Impaired Patients
Banala, S. K., Agrawal, S. K., & Scholz, J. P. (2007) · 2007 IEEE 10th International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2007.4428456 · Cited by 316 · cited 1×
“Some exoskeletons are stationary, mounted above treadmills and used to provide gait retraining or rehabilitation for those with disabilities or injuries (Jezernik et al., 2003; Banala et al., 2007; Veneman et al., 2007).”
BackgroundAlterations in muscle activation patterns during robotic-assisted walking
Hidler, J. M., & Wall, A. E. (2005) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2004.09.016 · Cited by 309 · cited 2×
“These parasitic torques as well as constrained non-actuated degrees of freedom can lead to deviation from the wearer’s natural motion, discomfort, or injuries (Hidler and Wall, 2005; Schiele, 2009; Pons, 2010).”
BackgroundThe Berkeley Lower Extremity Exoskeleton
Kazerooni, H., & Steger, R. (2006) · Journal of Dynamic Systems, Measurement, and Control · doi:10.1115/1.2168164 · Cited by 293
Tang, P.-F., Woollacott, M. H., & Chong, R. K. Y. (1998) · Experimental Brain Research · doi:10.1007/s002210050327 · Cited by 256 · cited 1×
“It has previously been shown that applying forces at the wrong time leads muscles to contract in order to compensate for the disturbance, which increases metabolic expenditure (Belanger and Patla, 1984; Tang et al., 1998).”
BackgroundA pneumatically powered knee-ankle-foot orthosis (KAFO) with myoelectric activation and inhibition
Sawicki, G. S., & Ferris, D. P. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-23 · Cited by 248
Effect of fatigue on leg kinematics and impact acceleration in long distance running
Mizrahi, J., Verbitsky, O., Isakov, E., & Daily, D. (2000) · Human Movement Science · doi:10.1016/s0167-9457(00)00013-0 · Cited by 247 · cited 1×
“During loaded walking, a wearable robot that can reduce metabolic expenditure will delay the onset of fatigue, thus lowering the risk of injury by enabling individuals to maintain proper form for longer periods of time (Mizrahi et al., 2000; Helbostad et al., 2007; Pohl et al., 2010).”
BackgroundBiologically-inspired soft exosuit
Asbeck, A. T., Dyer, R. J., Larusson, A. F., & Walsh, C. J. (2013) · 2013 IEEE 13th International Conference on Rehabilitation Robotics (ICORR) · doi:10.1109/icorr.2013.6650455 · Cited by 240 · cited 3×
“Looking to create a wearable robot that implements these features, we have recently proposed a new paradigm in assistive device design, namely soft clothing-like ‘‘exosuits’’ (Asbeck et al., 2013; Wehner et al., 2013).”
BackgroundMethodSelf-citationMechanics and energetics of swinging the human leg
Doke, J., Donelan, J. M., & Kuo, A. D. (2005) · Journal of Experimental Biology · doi:10.1242/jeb.01408 · Cited by 238 · cited 1×
“It is particularly important that the system be transparent during the swing phase of gait because the swinging leg acts like a pendulum (Doke et al., 2005), and external forces will disrupt the dynamics of that motion.”
BackgroundThe development and testing of a human machine interface for a mobile medical exoskeleton
Strausser, K. A., & Kazerooni, H. (2011) · 2011 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2011.6095025 · Cited by 226 · cited 2×
“These include exoskeletons that aim to help people walk while expending less energy (Kawamoto et al., 2003; Pratt et al., 2004; Ferris and Lewis, 2009; Sawicki and Ferris, 2009a,b; Strausser and Kazerooni, 2011), and those that assist with heavy lifting (Yamamoto et al., 2003; Wehner et al., 2009).”
BackgroundRehabilitation Exoskeletal Robotics
Pons, J. L. (2010) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2010.936548 · Cited by 222 · cited 2×
“These parasitic torques as well as constrained non-actuated degrees of freedom can lead to deviation from the wearer’s natural motion, discomfort, or injuries (Hidler and Wall, 2005; Schiele, 2009; Pons, 2010).”
BackgroundDesign and evaluation of Mina: A robotic orthosis for paraplegics
Neuhaus, P. D., Noorden, J. H., Craig, T. J., Torres, T., Kirschbaum, J., & Pratt, J. E. (2011) · 2011 IEEE International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2011.5975468 · Cited by 208 · cited 1×
“Devices in the former category are intended to be used by paralyzed individuals, enabling them to walk when they were previously unable to do so (Ackerman, 2010; Neuhaus et al., 2011; Esquenazi et al., 2012).”
BackgroundPhysical Fatigue Affects Gait Characteristics in Older Persons
Helbostad, J. L., Leirfall, S., Moe-Nilssen, R., & Sletvold, O. (2007) · The Journals of Gerontology Series A: Biological Sciences and Medical Sciences · doi:10.1093/gerona/62.9.1010 · Cited by 206 · cited 1×
“During loaded walking, a wearable robot that can reduce metabolic expenditure will delay the onset of fatigue, thus lowering the risk of injury by enabling individuals to maintain proper form for longer periods of time (Mizrahi et al., 2000; Helbostad et al., 2007; Pohl et al., 2010).”
BackgroundA portable powered ankle-foot orthosis for rehabilitation
Shorter, K. A., Kogler, G. F., Loth, E., Durfee, W. K., & Hsiao-Wecksler, E. T. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.04.0054 · Cited by 180 · cited 1×
“Several were designed exclusively for use by impaired individuals (Ohta et al., 2007; Quintero et al., 2011; Shorter et al., 2011), and these have been shown to improve walking speed or partially restore normal kinematics.”
BackgroundSawicki, G. S., & Ferris, D. P. (2009) · Journal of Experimental Biology · doi:10.1242/jeb.017269 · Cited by 179 · cited 2×
“These include exoskeletons that aim to help people walk while expending less energy (Kawamoto et al., 2003; Pratt et al., 2004; Ferris and Lewis, 2009; Sawicki and Ferris, 2009a,b; Strausser and Kazerooni, 2011), and those that assist with heavy lifting (Yamamoto et al., 2003; Wehner et al., 2009).”
BackgroundInfluentialAn Efficient Robotic Tendon for Gait Assistance
Hollander, K. W., Ilg, R., Sugar, T. G., & Herring, D. E. (2006) · Journal of Biomechanical Engineering · doi:10.1115/1.2264391 · Cited by 161 · cited 5×
“Second, the suit–human series stiffness is quite low as compared to most SEAs.”
BackgroundInfluentialSelf-Alignment Mechanisms for Assistive Wearable Robots: A Kinetostatic Compatibility Method
Cempini, M., Rossi, S., Lenzi, T., Vitiello, N., & Carrozza, M. C. (2012) · IEEE Transactions on Robotics · doi:10.1109/tro.2012.2226381 · Cited by 159 · cited 2×
“Alternately, mechanisms aligning robotic and human joints can be complicated, increasing the mass of the exoskeleton (Schiele, 2009; Ergin and Patoglu, 2011; Cempini et al., 2013).”
Background2015 IEEE International Conference on Rehabilitation Robotics (ICORR)
(2015) · doi:10.1109/icorr34445.2015 · Cited by 159
2007 IEEE 10th International Conference on Rehabilitation Robotics
(2007) · doi:10.1109/iccor12386.2007 · Cited by 155
International Conference on Control, Automation and Systems
Xuan, D.-J., Kim, J.-W., Zang, J.-I., & Kim, Y. (2007) · International Conference on Control, Automation and Systems (ICCAS) · doi:10.1109/iccas.2007.4406494 · Cited by 144
Robotic lower limb exoskeletons using proportional myoelectric control
Ferris, D. P., & Lewis, C. L. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5333984 · Cited by 136 · cited 2×
“These include exoskeletons that aim to help people walk while expending less energy (Kawamoto et al., 2003; Pratt et al., 2004; Ferris and Lewis, 2009; Sawicki and Ferris, 2009a,b; Strausser and Kazerooni, 2011), and those that assist with heavy lifting (Yamamoto et al., 2003; Wehner et al., 2009).”
BackgroundBio-inspired active soft orthotic device for ankle foot pathologies
Park, Y.-L., Chen, B.-R., Young, D., Stirling, L., Wood, R. J., Goldfield, E., & Nagpal, R. (2011) · 2011 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2011.6094933 · Cited by 130 · cited 2×
“Two of these robots are active soft orthotics that can provide slowly varying forces to the ankle (Park et al., 2011) or ankle and knee (Stirling et al.”
BackgroundLeg exoskeleton reduces the metabolic cost of human hopping
Grabowski, A. M., & Herr, H. (2009) · Journal of Applied Physiology · doi:10.1152/japplphysiol.91609.2008 · Cited by 122 · cited 1×
“For stationary activities, exoskeletons have been shown to reduce the wearer’s metabolic effort for squatting (Gams et al., 2013) and hopping (Grabowski and Herr, 2009).”
BackgroundMen and women adopt similar walking mechanics and muscle activation patterns during load carriage
Silder, A., Delp, S. L., & Besier, T. (2013) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.06.020 · Cited by 121 · cited 2×
“In addition, such a system would reduce the loading on soft tissue (muscles, tendons, ligaments) that can be up to several times greater than that sustained in unloaded walking (Silder et al., 2013) thus reducing the risk of injury.”
BackgroundJointless structure and under-actuation mechanism for compact hand exoskeleton
In, H., Cho, K., Kim, K., & Lee, B.-S. (2011) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2011.5975394 · Cited by 117
Effects of external pressure loading on human skin blood flow measured by 133Xe clearance
Holloway, G. A., Daly, C. H., Kennedy, D., & Chimoskey, J. E. (1976) · Journal of Applied Physiology · doi:10.1152/jappl.1976.40.4.597 · Cited by 109
Influence of Attachment Pressure and Kinematic Configuration on pHRI with Wearable Robots
Schiele, A., & van der Helm, F. C. T. (2009) · Applied Bionics and Biomechanics · doi:10.1080/11762320902879961 · Cited by 102
Control and implementation of a powered lower limb orthosis to aid walking in paraplegic individuals
Quintero, H., Farris, R. J., & Goldfarb, M. T. (2011) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2011.5975481 · Cited by 102 · cited 2×
“Several were designed exclusively for use by impaired individuals (Ohta et al., 2007; Quintero et al., 2011; Shorter et al., 2011), and these have been shown to improve walking speed or partially restore normal kinematics.”
BackgroundEffects of Robotic Knee Exoskeleton on Human Energy Expenditure
Gams, A., Petrič, T., Debevec, T., & Babič, J. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2240682 · Cited by 90 · cited 1×
“For stationary activities, exoskeletons have been shown to reduce the wearer’s metabolic effort for squatting (Gams et al., 2013) and hopping (Grabowski and Herr, 2009).”
BackgroundLower Extremity Exoskeleton Reduces Back Forces in Lifting
Wehner, M. F., Rempel, D. M., & Kazerooni, H. (2009) · ASME Dynamic Systems and Control Conference (DSCC) · doi:10.1115/dscc2009-2644 · Cited by 90 · cited 2×
“These include exoskeletons that aim to help people walk while expending less energy (Kawamoto et al., 2003; Pratt et al., 2004; Ferris and Lewis, 2009; Sawicki and Ferris, 2009a,b; Strausser and Kazerooni, 2011), and those that assist with heavy lifting (Yamamoto et al., 2003; Wehner et al., 2009).”
BackgroundErgonomics of exoskeletons: Objective performance metrics
Schiele, A. (2009) · IEEE World Haptics Conference (WHC) · doi:10.1109/whc.2009.4810871 · Cited by 90 · cited 3×
“Specifically, Schiele (2009) reports that joint torques of up to 1.46 Nm can be created due to joint misalignments that occur as an exoskeleton moves relative to the wearer over time, even if it was initially aligned correctly.”
BackgroundInfluentialA two-degree-of-freedom motor-powered gait orthosis for spinal cord injury patients
Ohta, Y., Yano, H., Suzuki, R., Yoshida, M., Kawashima, N., & Nakazawa, K. (2007) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/09544119jeim55 · Cited by 76 · cited 2×
“Several were designed exclusively for use by impaired individuals (Ohta et al., 2007; Quintero et al., 2011; Shorter et al., 2011), and these have been shown to improve walking speed or partially restore normal kinematics.”
Background2005 IEEE International Conference on Systems, Man, and Cybernetics
(2004) · IEEE Transactions on Systems Man and Cybernetics Part B (Cybernetics) · doi:10.1109/tsmcb.2004.840177 · Cited by 74
Applicability of Shape Memory Alloy Wire for an Active, Soft Orthotic
Stirling, L., Yu, C.-H., Miller, J., Hawkes, E. W., Wood, R. J., Goldfield, E. C., & Nagpal, R. (2011) · Journal of Materials Engineering and Performance · doi:10.1007/s11665-011-9858-7 · Cited by 73 · cited 1×
“Two of these robots are active soft orthotics that can provide slowly varying forces to the ankle (Park et al., 2011) or ankle and knee (Stirling et al., 2011).”
BackgroundViewpoint: On the hysteresis in the human Achilles tendon
Finni, T. J., Peltonen, J. T., Stenroth, L., & Cronin, N. J. (2012) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01005.2012 · Cited by 70 · cited 2×
“(Shadwick, 1990; Finni et al., 2013), which means that energy must be added to the suit as it relaxes to duplicate the behavior of muscles and tendons.”
BackgroundResultA self-adjusting knee exoskeleton for robot-assisted treatment of knee injuries
Ergin, M. A., & Patoğlu, V. (2011) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2011.6095073 · Cited by 69 · cited 2×
“Alternately, mechanisms aligning robotic and human joints can be complicated, increasing the mass of the exoskeleton (Cempini et al, 2013; Ergin and Patoglu, 2011; Schiele, 2009).”
BackgroundKobayashi, H., 松下, 泰., Ishida, Y., & KIKUCHI, K. (2002) · Journal of Robotics and Mechatronics · doi:10.20965/jrm.2002.p0046 · Cited by 65 · cited 2×
“have proposed exosuits to assist portions of the body besides the legs: one exosuit was designed to support the back during lifting tasks (Imamura et al, 2011; Tanaka et al, 2008), and another aids arm motions (Kobayashi, 2002).”
BackgroundDevelopment of Power Assisting Suit (Miniaturization of Supply System to Realize Wearable Suit)
YAMAMOTO, K., Ishii, M., HYODO, K., YOSHIMITSU, T., & Matsuo, T. (2003) · JSME International Journal Series C · doi:10.1299/jsmec.46.923 · Cited by 64 · cited 1×
“These include exoskeletons that aim to help people walk while expending less energy (Kawamoto et al., 2003; Pratt et al., 2004; Ferris and Lewis, 2009; Sawicki and Ferris, 2009a,b; Strausser and Kazerooni, 2011), and those that assist with heavy lifting (Yamamoto et al., 2003; Wehner et al., 2009).”
BackgroundExoskeletons for Human Performance Augmentation (EHPA): A Program Summary.
Garcia, E., Sater, J. M., & Main, J. A. (2002) · Journal of the Robotics Society of Japan · doi:10.7210/jrsj.20.822 · Cited by 64 · cited 1×
“These devices off-load the wearer, bypassing their musculature (Garcia et al., 2002; Kazerooni and Steger, 2006; Walsh et al., 2007).”
BackgroundCorrective responses to perturbation applied during walking in humans
Bélanger, M., & Patla, A. E. (1984) · Neuroscience Letters · doi:10.1016/0304-3940(84)90304-5 · Cited by 58 · cited 2×
“It has previously been shown that applying forces at the wrong time leads muscles to contract in order to compensate for the disturbance, which increases metabolic expenditure (Belanger and Patla, 1984; Tang et al., 1998).”
BackgroundMotion-based design of elastic belts for passive assistive device using musculoskeletal model
Imamura, Y., Tanaka, T., SUZUKI, Y., Takizawa, K., & Yamanaka, M. (2011) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio.2011.6181475 · Cited by 49 · cited 1×
“Other researchers have proposed exosuits to assist portions of the body besides the legs: one exosuit was designed to support the back during lifting tasks (Tanaka et al., 2008; Imamura et al., 2011), and another aids arm motions (Kobayashi, 2002).”
BackgroundKommu, S. S. (2007) · doi:10.5772/50 · Cited by 48
The role of tibialis posterior fatigue on foot kinematics during walking
Pohl, M. B., Rabbito, M., & Ferber, R. (2010) · Journal of Foot and Ankle Research · doi:10.1186/1757-1146-3-6 · Cited by 45 · cited 1×
“During loaded walking, a wearable robot that can reduce metabolic expenditure will delay the onset of fatigue, thus lowering the risk of injury by enabling individuals to maintain proper form for longer periods of time (Mizrahi et al., 2000; Helbostad et al., 2007; Pohl et al., 2010).”
BackgroundKawamura, T., Takanaka, K., Nakamura, T., & OSUMI, H. (2013) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2013.6650350 · Cited by 39 · cited 1×
“Another device provides small amounts of hip flexion torque to induce the wearer to change their step length (Kawamura et al., 2013).”
BackgroundBiomechanics of orthoses for the subluxed shoulder
Cool, J. C. (1989) · Prosthetics and Orthotics International · doi:10.3109/03093648909078219 · Cited by 34 · cited 3×
“5N/cm2 result in discomfort and restricted blood flow (Cool, 1989; Holloway et al, 1976).”
BackgroundInfluentialGregorczyk, K. N., Obusek, J. P., Hasselquist, L., Bensel, J. M. S., Carolyn, K., Gutekunst, D. J., & Frykman, P. (2006) · Defense Technical Information Center (DTIC) · Cited by 20
Research works printed but not linked: 7
- Brockway JM, 1987, Human Nutrition. Clinical Nutrition, 41, 463
- In H, 2011, 2011 IEEE international conference on rehabilitation robotics (ICORR), 1
- Neuhaus PD, 2011, 2011 IEEE international conference on rehabilitation robotics (ICORR), 1
- Quintero H, 2011, 2011 IEEE international conference on rehabilitation robotics (ICORR), 1
- Rose J, 2006, Human Walking
- 10.1155/2009/829219 · doi:10.1155/2009/829219
- Vanoglio F, 2013, XIII congress of Italian Society of Neurorehabilitation
Cited by
Biomedical applications of soft robotics
Cianchetti, M., Laschi, C., Menciassi, A., & Dario, P. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0022-y · Cited by 1,435
A soft robotic exosuit improves walking in patients after stroke
Awad, L. N., Bae, J., O’Donnell, K., De Rossi, S. M. M., Hendron, K., Sloot, L. H., Kudzia, P., Allen, S., Holt, K. G., Ellis, T. D., et al. (2017) · Science Translational Medicine · doi:10.1126/scitranslmed.aai9084 · Cited by 672
Self-citationFlexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Capacitive Soft Strain Sensors via Multicore–Shell Fiber Printing
Frutiger, A., Muth, J. T., Vogt, D. M., Mengüç, Y., Campo, A., Valentine, A. D., Walsh, C. J., & Lewis, J. A. (2015) · Advanced Materials · doi:10.1002/adma.201500072 · Cited by 468
Self-citationSystematic review on wearable lower-limb exoskeletons for gait training in neuromuscular impairments
Rodríguez-Fernández, A., Lobo-Prat, J., & Font-Llagunes, J. M. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00815-5 · Cited by 435
Metadata
- Authors
- Asbeck, A. T., De Rossi, S. M. M., Holt, K. G., & Walsh, C. J.
- Affiliations
- Harvard University (US)
- Harvard University, Cambridge, MA, USA
- Boston University (US)
- Venue
- The International Journal of Robotics Research
- Publisher
- SAGE Publications
- Published
- 2015-03-16
- Volume
- 34
- Issue
- 6
- Pages
- 744-762
- ISSN
- 0278-3649 (ISSN-L)
- 1741-3176
- OpenAlex
- W2169410184
- Semantic Scholar
- 6f5747b1e1a55a0b7c475d4d70e90e139f3e74d5
- Cited by
- 450
- References
- 66
- Citations by year
- 2026: 34 · 2025: 43 · 2024: 38 · 2023: 40 · 2022: 39 · 2021: 63 · 2020: 48 · 2019: 43 · 2018: 42 · 2017: 33 · 2016: 21 · 2015: 4
- FWCI
- 16.58
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- The International Journal of Robotics Research (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- soft exosuit, gait assistance, biologically inspired design, energy cost of walking, loaded walking, gait kinematics, wearable robotics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›