Stem Cells Genetically Modified With the Developmental Gene MT1-MMP Improve Regeneration of the Supraspinatus Tendon-to-Bone Insertion Site
The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
Background: Rotator cuffs heal through a scar tissue interface after repair, which makes them prone to failure. Membrane type 1 matrix metalloproteinase (MT1-MMP) is upregulated during embryogenesis in areas that develop into tendon-bone insertion sites. Hypothesis: Bone marrow-derived stem cells in the presence of the developmental signal from MT1-MMP will drive the healing process toward regeneration and away from scar formation. Study Design: Controlled laboratory study. Methods: Sixty Lewis rats underwent unilateral detachment and repair of the supraspinatus tendon. Thirty animals received mesenchymal stem cells (MSCs) in a fibrin glue carrier, and 30 received adenoviral MT1-MMP (Ad-MT1-MMP)–transduced MSCs. Animals were sacrificed at 2 weeks and 4 weeks and evaluated for the presence of fibrocartilage and collagen fiber organization at the insertion. Biomechanical testing was performed to determine the structural and material properties of the repaired tissue. Statistical analysis was performed with a Wilcoxon rank-sum test with significance set at P = .05. Results: There were no differences between the Ad-MT1-MMP and MSC groups in any outcome variable at 2 weeks. At 4 weeks, the Ad-MT1-MMP group had more fibrocartilage ( P = .05), higher ultimate load to failure ( P = .01), higher ultimate stress to failure ( P = .005), and higher stiffness values ( P = .02) as compared with the MSC group. Conclusion: Mesenchymal stem cells genetically modified to overexpress the developmental gene MT1-MMP can augment rotator cuff healing at 4 weeks by the presence of more fibrocartilage at the insertion and improved biomechanical strength. Clinical Relevance: Biologic augmentation of repaired rotator cuffs with MT1-MMP–transduced MSCs may reduce the incidence of retears. However, further studies are needed to determine if this remains safe and effective in larger models.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Junqueira, L. C. U., Bignolas, G., & Brentani, R. R. (1979) · The Histochemical Journal · doi:10.1007/bf01002772 · Cited by 2,574
A matrix metalloproteinase expressed on the surface of invasive tumour cells
Sato, H., Takino, T., Okada, Y., Cao, J., Shinagawa, A., Yamamoto, E., & Seiki, M. (1994) · Nature · doi:10.1038/370061a0 · Cited by 2,551 · cited 2×
“It has been a gene of great interest in cancer research as its proteolytic activity of the surrounding basement membrane allows for the local metastasis of tumor cells.(37) Theoretically, MT1-MMP might help improve tendonbone healing by 2 mechanisms.”
BackgroundGalatz, L. M., Ball, C. M., Teefey, S. A., Middleton, W. D., & Yamaguchi, K. (2004) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-200402000-00002 · Cited by 2,145 · cited 2×
“Failure at the tendon attachment site is a relatively common occurrence after rotator cuff repair surgery.(6,7,11,16,20,24,40) Although advances in surgical technique have attempted to overcome this problem, incomplete or failed healing continues to limit rotator cuff function after repair.”
BackgroundPhinney, D. G., & Prockop, D. J. (2007) · Stem Cells · doi:10.1634/stemcells.2007-0637 · Cited by 1,908 · cited 1×
“Mesenchymal stem cells are multipotent fibroblast-like cells that are capable of differentiating to multiple connective tissue cell types including osteoblasts, adipocytes, and chondrocytes in vitro.(34) Several animal transplantation studies have found that these cells are able to augment the local repair and regener…”
BackgroundHorwitz, E. M., Gordon, P. L., Koo, W. K. K., Marx, J. C., Neel, M. D., McNall, R. Y., Muul, L., & Hofmann, T. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.132252399 · Cited by 1,650 · cited 1×
“For example, in a clinical trial using MSCs to treat children with osteogenesis imperfecta, improvements were seen in ambulation, bone mineral density, and growth velocity; yet, the levels of grafted donor MSCs in tissues were found to be less than 1%.(15) Moreover, Tremain et al(41) showed that multiple subpopulation…”
BackgroundRepairs of the rotator cuff. Correlation of functional results with integrity of the cuff.
Harryman, D. T., Mack, L. A., Wang, K. Y., Jackins, S. E., Richardson, M. L., & Matsen, F. A. (1991) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199173070-00004 · Cited by 1,259
Tendon-healing in a bone tunnel. A biomechanical and histological study in the dog.
Rodeo, S. A., Arnoczky, S. P., Torzilli, P. A., Hidaka, C., & Warren, R. F. (1993) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199312000-00009 · Cited by 1,104 · cited 1×
“We have previously shown that improvements in tendon-to-bone healing pullout strengths are directly related to bone ingrowth into the healing interface tissue.(36) Taken together, it is reasonable to hypothesize that MT1-MMP results in increased levels of COX-2 that in turn promotes bone and cartilage incorporation in…”
BackgroundSelf-citationRepair Integrity and Functional Outcome After Arthroscopic Double-Row Rotator Cuff Repair
Sugaya, H., Maeda, K., Matsuki, K., et al. (2007) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.f.00512 · Cited by 859 · cited 2×
“Failure at the tendon attachment site is a relatively common occurrence after rotator cuff repair surgery.(6,7,11,16,20,24,40) Although advances in surgical technique have attempted to overcome this problem, incomplete or failed healing continues to limit rotator cuff function after repair.”
BackgroundSekiya, I., Vuoristo, J. T., Larson, B. L., & Prockop, D. J. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.052716199 · Cited by 648
Repair Integrity and Functional Outcome After Arthroscopic Double-Row Rotator Cuff Repair
Sugaya, H., Maeda, K., Matsuki, K., et al. (2007) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-200705000-00006 · Cited by 620
Cited by
Docheva, D., Müller, S. A., Majewski, M., & Evans, C. H. (2015) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.11.015 · Cited by 693
Functional Attachment of Soft Tissues to Bone: Development, Healing, and Tissue Engineering
Lu, H. H., & Thomopoulos, S. (2013) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071910-124656 · Cited by 447
Gulotta, L. V., Kovacevic, D., Packer, J. D., Deng, X. H., & Rodeo, S. A. (2011) · The American Journal of Sports Medicine · doi:10.1177/0363546510395485 · Cited by 307
Self-citationTendon and Ligament Healing and Current Approaches to Tendon and Ligament Regeneration
Leong, N. L., Kator, J. L., Clemens, T. L., James, A., Enamoto‐Iwamoto, M., & Jiang, J. (2020) · Journal of Orthopaedic Research · doi:10.1002/jor.24475 · Cited by 286
Transcription factor EGR1 directs tendon differentiation and promotes tendon repair
Guerquin, M.-J., Charvet, B., Nourissat, G., Havis, E., Ronsin, O., Bonnin, M.-A., Ruggiu, M., Olivera-Martinez, I., Robert, N., Lu, Y., et al. (2013) · Journal of Clinical Investigation · doi:10.1172/jci67521 · Cited by 259
The role of bone marrow derived mesenchymal stem cells in sports injuries
Vris, A., Aresti, N., Khan, W. S., & Malik, A. A. (2016) · Stem Cells in Clinical Applications · doi:10.1007/978-3-319-40144-7_14 · Cited by 28
Metadata
- Authors
- Gulotta, L. V., Kovacevic, D., Montgomery, S., Ehteshami, J. R., Packer, J. D., & Rodeo, S. A.
- Venue
- The American Journal of Sports Medicine
- Publisher
- SAGE Publications
- Published
- 2010-04-16
- Volume
- 38
- Issue
- 7
- Pages
- 1429-1437
- ISSN
- 0363-5465 (ISSN-L)
- 1552-3365
- OpenAlex
- W2013057349
- Cited by
- 172
- References
- 40
- FWCI
- 14.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.