CoChat

The effects of processing techniques on the mechanical properties of bone-anterior cruciate ligament-bone allografts: An experimental study in goats

Jackson, D.W., Grood, E.S., Wilcox, P., Butler, D.L., Simon, T.M., Holden, J.P. · 1988 · The American Journal of Sports Medicine
Cited by 90

The DOI matches its Crossref record.

Abstract

There has been a growing interest in the use of allo grafts as ACL substitutes. Allografts are often freeze dried to increase shelf storage time and sterilized with ethylene oxide. This study was conducted to determine the effect of a specific ethylene oxide sterilization pro cedure and freeze drying process on the initial mechan ical properties of femur-ACL-tibia preparations. Twelve knees (stifle joints) from six mature goats were divided into two groups (one knee of pair to each group). Knees were cleaned of all soft tissue except for the anterior cruciate, posterior cruciate, and collateral ligaments. Group 1 was sterilized with ethylene oxide (simulating clean procurement) then freeze dried. Group 2 was freeze dried only (simulating sterile procurement). The knees were rehydrated and then tested in tension to failure to determine their structural mechanical proper ties. The ethylene oxide-freeze dried specimens (Group 1) had a mean maximum load before failure of 2059 ± 273 newtons (N) (± SE) which was not statistically different than the maximum load of the freeze dried specimens (Group 2) of 2023 ± 214 N. The average strength of Group 1 and 2 combined was not signifi cantly different than a third group of 12 normal femur- ACL-tibia controls which had an average maximum force of 2403 ± 133 N. No significant differences be tween the groups were observed for stiffness, energy to maximum strength, or elongation to maximum force. It appears the freeze dry processing, with or without ethylene oxide sterilization, using the procedure we used, has, at most, a small effect on the initial mechan ical properties of the preparations. The low mechanical properties of implanted and revascularized allografts, as compared to normal femur-ACL-tibia complex ap pears to be related more to fixation strength and alter ations which occur in the ligament substance after implantation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/036354658801600203

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Jackson, D. W., Grood, E. S., Wilcox, P., Butler, D. L., Simon, T. M., & Holden, J. P.
Venue
The American Journal of Sports Medicine
Published
1988-03
Volume
16
Issue
2
Pages
101-105
ISSN
  • 0363-5465 (ISSN-L)
  • 1552-3365
OpenAlex
W1980876898
Cited by
90
References
0
FWCI
2.58
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.