Phase-Amplitude Resetting of the Human Circadian Pacemaker via Bright Light: A Further Analysis
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
We present here an analysis of strong, weak, and critical bright-light resetting trials in humans, and report not only phase but also amplitude data for the first time. For this analysis, an appropriate iterative smoothing procedure for phase transition curves is introduced, in which the data are sequenced so as to minimize the perpendicular distance from the data to the smoothed fit. From these smoothed data, we create polar phase-amplitude resetting maps (PARMs) in order to fully illustrate the effects of the resetting stimuli on both circadian amplitude and phase, and thereby to determine whether these resetting results can be decribed by a phase-only model or whether a phase-amplitude model is required. Our results indicate that a single 5-hr episode of bright light induces weak type 1 resetting of the human circadian pacemaker. Two cycles of exposure to the same stimulus on consecutive days induce critical resetting, in which significant amplitude reduction may be observed. A three-cycle stimulus induces strong type 0 resetting with different effects on circadian amplitude, depending on the initial phase of the stimulus application. When a three-cycle stimulus is centered near the nadir of the temperature cycle, large phase shifts are achieved via amplitude suppression. However, when this stimulus is centered away from the temperature nadir, smaller phase shifts are achieved in which both small increases and small decreases in circadian amplitude are observed. These data indicate that the human circadian pacemaker is not a simple, phase-only oscillator. Instead, a full description of human circadian resetting responses to light requires analysis of both phase and amplitude data—a finding that is consistent with a phase-amplitude model of the circadian resetting mechanism.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Geometry of Biological Time
Winfree, A. T. (1980) · doi:10.1007/978-3-662-22492-2 · Cited by 3,613
Bright Light Induction of Strong (Type 0) Resetting of the Human Circadian Pacemaker
Czeisler, C. A., Kronauer, R. E., Allan, J. S., Duffy, J. F., Jewett, M. E., Brown, E. N., & Ronda, J. M. (1989) · Science · doi:10.1126/science.2734611 · Cited by 946
Self-citationBright light resets the human circadian pacemaker independent of the timing of the sleep-wake cycle
Czeisler, C. A., Allan, J. S., Strogatz, S. H., Ronda, J. M., Sánchez, R., Ríos, C. D., Freitag, W. O., Richardson, G. S., & Kronauer, R. E. (1986) · Science · doi:10.1126/science.3726555 · Cited by 770
Association of sleep-wake habits in older people with changes in output of circadian pacemaker
Czeisler, C. A., Dumont, M., Duffy, J. F., Steinberg, J. D., Richardson, G. S., Brown, E. N., Sánchez, R., Ríos, C. D., & Ronda, J. M. (1992) · The Lancet · doi:10.1016/0140-6736(92)92817-y · Cited by 437
Self-citationAdaptation to abrupt time shifts of the oscillator(s) controlling human circadian rhythms.
Mills, J. N., Minors, D. S., & Waterhouse, J. M. (1978) · The Journal of Physiology · doi:10.1113/jphysiol.1978.sp012582 · Cited by 285
Research works printed but not linked: 37
- 10.1177/074873049300800407 · DOI
- 10.1177/074873049300800410 · doi:10.1177/074873049300800410
- Bloomfield, P., 1976, Fourier Analysis of Time Series: An Introduction
- 10.1177/074873049200700301 · DOI · Paper page
- 10.1016/0304-3940(91)90646-B · DOI
- Campbell, S.S., 1993, Sleep, 16, 638
- Chandrashekaran, M.K., 1976, Int. J. Chronobiol., 3, 231
- . Czeisler, C.A. (1994) The effect of light on the human circadian pacemaker. In Circadian Clocks and Their Adjustment, Ciba Foundation Symposium No. 183, pp. 254-302, Wiley, Chichester, England. · DOI · Paper page
- Czeisler, C.A., J.S. Allan, and R.E. Kronauer (1990) A method for assaying the effects of therapeutic agents on the period of the endogenous circadian pacemaker in man In Sleep and Biological Rhythms: Basic Mechanisms and Applications to Psychiatry, J. Montplaisir and R. Godbout, eds., pp. 87-98, Oxford University Press, New York.
- Czeisler, C.A., and M.E. Jewett (1990) Human circadian physiology: Interaction of the behavioral rest-activity cycle with the output of the endogenous circadian pacemaker In Handbook of Sleep Disorders, M. J. Thorpy, ed., pp. 117-137, Marcel Dekker, New York.
- 10.3109/07420529309059697 · DOI · Paper page
- 10.1111/j.1399-3054.1978.tb01569.x · DOI
- Glass, L., 1984, Am. J. Physiol, 246, R251
- 10.2307/1539108 · DOI · Paper page
- Honma, K., 1988, Japan J. Psychiat. Neurol, 42, 167
- 10.1007/BF01945525 · DOI
- 10.1038/350059a0 · DOI · Paper page
- Johnson, C.H., 1990, An Atlas of Phase Response Curves for Circadian and Circatidal Rhythms,
- 10.1111/j.1600-079X.1987.tb00869.x · DOI
- Keeping, E.S., 1962, Introduction to Statistical Inference
- Kronauer, R.E. (1990) A quantitative model for the effects of light on the amplitude and phase of the deep circadian pacemaker, based on human data In Sleep '90: Proceedings of the Tenth European Congress on Sleep Research, J. Home, ed., pp. 306-309, Pontenagel Press, Düsseldorf, Germany.
- 10.1016/B978-0-08-042279-4.50019-4 · DOI
- 10.1177/074873049300800409 · DOI
- 10.1177/074873049300800408 · DOI
- 10.1177/074873049100600401 · DOI · Paper page
- 10.1007/BF00685221 · doi:10.1007/bf00685221
- 10.1016/0304-3940(91)90051-T · DOI · Paper page
- 10.1007/BF00657038 · DOI
- 10.1073/pnas.44.9.965 · DOI · Paper page
- 10.1177/074873049100600402 · DOI · Paper page
- Shanahan, T.L., 1991, Sleep Res., 20, 557
- 10.1177/074873049000500208 · DOI
- Van Cauter, E., 1993, J. Biol. Rhythms, 8, S99
- 10.1016/0022-5193(70)90075-5 · DOI · Paper page
- 10.1007/BF00696471 · DOI
- Winfree, A.T., 1987, The Timing of Biological Clocks
- 10.1177/074873049200700201 · DOI
Cited by
Zeitzer, J. M., Dijk, D., Kronauer, R. E., Brown, E. N., & Czeisler, C. A. (2000) · The Journal of Physiology · doi:10.1111/j.1469-7793.2000.00695.x · Cited by 1,175
“It was thus centred 3·5 h before Tmin, a time during which bright light is known to induce phase delays of the circadian system (Jewett et al. 1994).”
BackgroundSelf-citationA Phase Response Curve to Single Bright Light Pulses in Human Subjects
Khalsa, S. B. S., Jewett, M. E., Cajochen, C., & Czeisler, C. A. (2003) · The Journal of Physiology · doi:10.1113/jphysiol.2003.040477 · Cited by 1,040
Self-citationRajaratnam, S. M., & Arendt, J. (2001) · The Lancet · doi:10.1016/s0140-6736(01)06108-6 · Cited by 711
Dose-response relationships for resetting of human circadian clock by light
Boivin, D. B., Duffy, J. F., Kronauer, R. E., & Czeisler, C. A. (1996) · Nature · doi:10.1038/379540a0 · Cited by 559
Self-citationPandi-Perumal, S. R., Smits, M., Spence, W., Srinivasan, V., Cardinali, D. P., Lowe, A. D., & Kayumov, L. (2007) · Progress in Neuro-Psychopharmacology and Biological Psychiatry · doi:10.1016/j.pnpbp.2006.06.020 · Cited by 419
Metadata
- Authors
- Jewett, M. E., Kronauer, R. E., & Czeisler, C. A.
- Venue
- Journal of Biological Rhythms
- Publisher
- SAGE Publications
- Published
- 1994-12
- Volume
- 9
- Issue
- 3-4
- Pages
- 295-314
- ISSN
- 0748-7304 (ISSN-L)
- 1552-4531
- OpenAlex
- W2095492811
- Cited by
- 149
- References
- 5
- FWCI
- 2.46
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.