Irreversible Electroporation: A New Ablation Modality — Clinical Implications
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
Irreversible electroporation (IRE) is a new tissue ablation technique in which micro to millisecond electrical pulses are delivered to undesirable tissue to produce cell necrosis through irreversible cell membrane permeabilization. IRE affects only the cell membrane and no other structure in the tissue. The goal of the study is to test our IRE tissue ablation methodology in the pig liver, provide first experience results on long term histopathology of IRE ablated tissue, and discuss the clinical implications of the findings. The study consists of: a) designing an IRE ablation protocol through a mathematical analysis of the electrical field during electroporation; b) using ultrasound to position the electroporation electrodes in the predetermined locations and subsequently to monitor the process; c) applying the predetermined electrotroporation pulses; d) performing histolopathology on the treated samples for up to two weeks after the procedure; and e) correlating the mathematical analysis, ultrasound data, and histology. We observed that electroporation affects tissue in a way that can be imaged in real time with ultrasound, which should facilitate real time control of electroporation during clinical applications. We observed cell ablation to the margin of the treated lesion with several cells thickness resolution. There appears to be complete ablation to the margin of blood vessels without compromising the functionality of the blood vessels, which suggests that IRE is a promising method for treatment of tumors near blood vessels (a significant challenge with current ablation methods). Consistent with the mechanism of action of IRE on the cell membrane only, we show that the structure of bile ducts, blood vessels, and connective tissues remains intact with IRE. We report extremely rapid resolution of lesions, within two weeks, which is consistent with retention of vasculature. We also document tentative evidence for an immunological response to the ablated tissue. Last, we show that mathematical predictions with the Laplace equation can be used in treatment planning. The IRE tissue ablation technique, as characterized in this report, may become an important new tool in the surgeon armamentarium.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/002 · Cited by 4,270
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/003 · Cited by 4,175
The dielectric properties of biological tissues: I. Literature survey
Gabriel, C., Gabriel, S., & Corthout, E. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/001 · Cited by 3,156
Gene transfer into mouse lyoma cells by electroporation in high electric fields.
Neumann, E., Schaefer-Ridder, M., Wang, Y., & Hofschneider, P. H. (1982) · The EMBO Journal · doi:10.1002/j.1460-2075.1982.tb01257.x · Cited by 2,502
Tissue Ablation with Irreversible Electroporation
Davalos, R. V., Mir, L. M., & Rubinsky, B. (2005) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-8981-8 · Cited by 1,293
Self-citationElectroporation: theory and methods, perspectives for drug delivery, gene therapy and research
Gehl, J. (2003) · Acta Physiologica Scandinavica · doi:10.1046/j.1365-201x.2003.01093.x · Cited by 973
Dielectric Breakdown of Cell Membranes
Zimmermann, U., Pilwat, G., & Riemann, F. (1974) · Biophysical Journal · doi:10.1016/s0006-3495(74)85956-4 · Cited by 762
Permeability changes induced by electric impulses in vesicular membranes
Neumann, E., & Rosenheck, K. (1972) · The Journal of Membrane Biology · doi:10.1007/bf01867861 · Cited by 709
A NEW METHOD FOR THE GENERATION AND USE OF FOCUSED ULTRASOUND IN EXPERIMENTAL BIOLOGY
Lynn, J. G., Zwemer, R. L., Chick, A. J., & Miller, A. E. (1942) · Journal of General Physiology · doi:10.1085/jgp.26.2.179 · Cited by 690
In Vivo Results of a New Focal Tissue Ablation Technique: Irreversible Electroporation
Edd, J. F., Horowitz, L., Davalos, R. V., Mir, L. M., & Rubinsky, B. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.873745 · Cited by 510
Self-citationElectrophysiologic Principles of Radiofrequency Lesion Making
Organ, L. W. (1976) · Stereotactic and Functional Neurosurgery · doi:10.1159/000102478 · Cited by 415
Electrical Breakdown of Bimolecular Lipid Membranes as an Electromechanical Instability
Crowley, J. M. (1973) · Biophysical Journal · doi:10.1016/s0006-3495(73)86017-5 · Cited by 392
Miklavčič, D., Šemrov, D., Mekid, H., & Mir, L. M. (2000) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/s0304-4165(00)00101-x · Cited by 366
Electroporation of cells and tissues
Weaver, J. C. (2000) · IEEE Transactions on Plasma Science · doi:10.1109/27.842820 · Cited by 353
Calcium-dependent exocytosis in bovine adrenal medullary cells with leaky plasma membranes
BAKER, P. F., & KNIGHT, D. E. (1978) · Nature · doi:10.1038/276620a0 · Cited by 312
Electroporation of Cells and Tissues
Weaver, J. (1999) · Electrical Engineering Handbook · doi:10.1201/9781420049510.ch94 · Cited by 299
Cancer Cells Ablation with Irreversible Electroporation
Miller, L., Leor, J., & Rubinsky, B. (2005) · Technology in Cancer Research & Treatment · doi:10.1177/153303460500400615 · Cited by 298
Self-citationCoster, H. G. L. (1965) · Biophysical Journal · doi:10.1016/s0006-3495(65)86745-5 · Cited by 297
Rubinsky, B. (2000) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.2.1.157 · Cited by 237
Self-citation(2009) · Institute of Electrical and Electronics Engineers eBooks · doi:10.1109/9780470546796.ch2 · Cited by 128
Electrical Impedance Tomography for Imaging Tissue Electroporation
Davalos, R. V., Otten, D. M., Mir, L. M., & Rubinsky, B. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.824148 · Cited by 122
Self-citationDavalos, R. V., Rubinsky, B., & Otten, D. M. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.991168 · Cited by 104
Self-citationRowan, N. J., MacGregor, S. J., Anderson, J. G., Fouracre, R. A., & Farish, O. (2000) · Letters in Applied Microbiology · doi:10.1046/j.1365-2672.2000.00772.x · Cited by 89
Cited by
Thermal ablation of tumours: biological mechanisms and advances in therapy
Chu, K. F., & Dupuy, D. E. (2014) · Nature Reviews Cancer · doi:10.1038/nrc3672 · Cited by 1,988
Principles of and Advances in Percutaneous Ablation
Ahmed, M., Brace, C. L., Lee, F. T., & Goldberg, S. N. (2011) · Radiology · doi:10.1148/radiol.10081634 · Cited by 916
Electroporation-Based Technologies for Medicine: Principles, Applications, and Challenges
Yarmush, M. L., Golberg, A., Serša, G., Kotnik, T., & Miklavčič, D. (2014) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071813-104622 · Cited by 889
Pulsed Field Ablation for Pulmonary Vein Isolation in Atrial Fibrillation
Reddy, V. Y., Neuzil, P., Koruth, J. S., Petru, J., Funosako, M., Cochet, H., Sediva, L., Chovanec, M., Dukkipati, S. R., & Jais, P. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2019.04.021 · Cited by 700
Pulsed Field Ablation of Paroxysmal Atrial Fibrillation
Reddy, V. Y., Dukkipati, S. R., Neuzil, P., Anic, A., Petru, J., Funasako, M., Cochet, H., Minami, K., Breskovic, T., Sikiric, I., et al. (2021) · JACC: Clinical Electrophysiology · doi:10.1016/j.jacep.2021.02.014 · Cited by 558
Metadata
- Authors
- Rubinsky, B., Onik, G., & Mikus, P.
- Venue
- Technology in Cancer Research & Treatment
- Publisher
- SAGE Publications
- Published
- 2007-02
- Volume
- 6
- Issue
- 1
- Pages
- 37-48
- ISSN
- 1533-0338 (ISSN-L)
- 1533-0346
- OpenAlex
- W2146996882
- Cited by
- 781
- References
- 23
- FWCI
- 23.21
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.