CoChat

Irreversible Electroporation: A New Ablation Modality — Clinical Implications

Open access
Rubinsky, Boris, Onik, Gary, Mikus, Paul · 2007 · Technology in Cancer Research & Treatment
Cited by 781

The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.

Abstract

Irreversible electroporation (IRE) is a new tissue ablation technique in which micro to millisecond electrical pulses are delivered to undesirable tissue to produce cell necrosis through irreversible cell membrane permeabilization. IRE affects only the cell membrane and no other structure in the tissue. The goal of the study is to test our IRE tissue ablation methodology in the pig liver, provide first experience results on long term histopathology of IRE ablated tissue, and discuss the clinical implications of the findings. The study consists of: a) designing an IRE ablation protocol through a mathematical analysis of the electrical field during electroporation; b) using ultrasound to position the electroporation electrodes in the predetermined locations and subsequently to monitor the process; c) applying the predetermined electrotroporation pulses; d) performing histolopathology on the treated samples for up to two weeks after the procedure; and e) correlating the mathematical analysis, ultrasound data, and histology. We observed that electroporation affects tissue in a way that can be imaged in real time with ultrasound, which should facilitate real time control of electroporation during clinical applications. We observed cell ablation to the margin of the treated lesion with several cells thickness resolution. There appears to be complete ablation to the margin of blood vessels without compromising the functionality of the blood vessels, which suggests that IRE is a promising method for treatment of tumors near blood vessels (a significant challenge with current ablation methods). Consistent with the mechanism of action of IRE on the cell membrane only, we show that the structure of bile ducts, blood vessels, and connective tissues remains intact with IRE. We report extremely rapid resolution of lesions, within two weeks, which is consistent with retention of vasculature. We also document tentative evidence for an immunological response to the ablated tissue. Last, we show that mathematical predictions with the Laplace equation can be used in treatment planning. The IRE tissue ablation technique, as characterized in this report, may become an important new tool in the surgeon armamentarium.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/153303460700600106

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 23 references

Cited by

Metadata

Authors
Rubinsky, B., Onik, G., & Mikus, P.
Venue
Technology in Cancer Research & Treatment
Published
2007-02
Volume
6
Issue
1
Pages
37-48
ISSN
  • 1533-0338 (ISSN-L)
  • 1533-0346
OpenAlex
W2146996882
Cited by
781
References
23
FWCI
23.21
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.