The relevance and potential roles of microphysiological systems in biology and medicine
Open accessThe DOI matches its Crossref record; 78 of the 78 references it cites were found in a registry or an index.
Abstract
Microphysiological systems (MPS), consisting of interacting organs-on-chips or tissue-engineered, 3D organ constructs that use human cells, present an opportunity to bring new tools to biology, medicine, pharmacology, physiology, and toxicology. This issue of Experimental Biology and Medicine describes the ongoing development of MPS that can serve as in-vitro models for bone and cartilage, brain, gastrointestinal tract, lung, liver, microvasculature, reproductive tract, skeletal muscle, and skin. Related topics addressed here are the interconnection of organs-on-chips to support physiologically based pharmacokinetics and drug discovery and screening, and the microscale technologies that regulate stem cell differentiation. The initial motivation for creating MPS was to increase the speed, efficiency, and safety of pharmaceutical development and testing, paying particular regard to the fact that neither monolayer monocultures of immortal or primary cell lines nor animal studies can adequately recapitulate the dynamics of drug-organ, drug-drug, and drug-organ-organ interactions in humans. Other applications include studies of the effect of environmental toxins on humans, identification, characterization, and neutralization of chemical and biological weapons, controlled studies of the microbiome and infectious disease that cannot be conducted in humans, controlled differentiation of induced pluripotent stem cells into specific adult cellular phenotypes, and studies of the dynamics of metabolism and signaling within and between human organs. The technical challenges are being addressed by many investigators, and in the process, it seems highly likely that significant progress will be made toward providing more physiologically realistic alternatives to monolayer monocultures or whole animal studies. The effectiveness of this effort will be determined in part by how easy the constructs are to use, how well they function, how accurately they recapitulate and report human pharmacology and toxicology, whether they can be generated in large numbers to enable parallel studies, and if their use can be standardized consistent with the practices of regulatory science.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“MPSs have evolved into a powerful alternative for classical cell culture and animal models by providing physiological microenvironments embedded in a vascular-like microfluidic perfusion (reviewed in Wikswo, 2014; Zhang et al., 2018).”
From Merging organoid and organ-on-a-chip technology to generate complex multi-layer tissue models in a human retina-on-a-chip platform (2019) · cites this paper as Wikswo, 2014
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gadamer, H. G., Weinsheimer, J. C., & Marshall, D. G. (1960) · Cited by 9,338
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250
Can the pharmaceutical industry reduce attrition rates?
Kola, I., & Landis, J. (2004) · Nature Reviews Drug Discovery · doi:10.1038/nrd1470 · Cited by 4,167 · cited 1×
“Nowhere would such predictions be more important than in support of the development of new drugs, in particular the anticipation of the efficacy, toxicity, and safety of a drug in humans.(13,14) Although there is a growing suite of techniques, primarily through optogenetics,(15,16) that enable interrogation of intact…”
BackgroundBissell, M. J., & Radisky, D. (2001) · Nature Reviews Cancer · doi:10.1038/35094059 · Cited by 2,180 · cited 2×
“Unfortunately, neither genetics nor current studies of static monolayer monocultures of cell lines with periodic media replacement fully inform us as to how cells will interact with a three-dimensional (3D), perfused microenvironment that includes cells of other types.(11,12) Vascular perfusion and its shear forces po…”
BackgroundStructural and molecular interrogation of intact biological systems
Chung, K., Wallace, J., Kim, S.-Y., Kalyanasundaram, S., Andalman, A. S., Davidson, T. J., Mirzabekov, J. J., Zalocusky, K. A., Mattis, J., Denisin, A. K., et al. (2013) · Nature · doi:10.1038/nature12107 · Cited by 2,008
Deconstructing the third dimension – how 3D culture microenvironments alter cellular cues
Baker, B. M., & Chen, C. S. (2012) · Journal of Cell Science · doi:10.1242/jcs.079509 · Cited by 1,760
Kim, H. J., Huh, D., Hamilton, G., & Ingber, D. E. (2012) · Lab on a Chip · doi:10.1039/c2lc40074j · Cited by 1,734 · cited 1×
“Today, individual cell types require customized media, yet this problem may be minimized by the use of endothelial and epithelial barriers to isolate the cellular microenvironment from surrounding fluids.(20,21,31) The isolated organ studies in Figure 2a and b used bovine blood, but the investigators had already notic…”
Untersuchungen am überlebenden Säugethierherzen
Langendorff, O. (1895) · Pflüger, Archiv für die Gesammte Physiologie des Menschen und der Thiere · doi:10.1007/bf01812150 · Cited by 1,325
Point of Care Diagnostics: Status and Future
Gubala, V., Harris, L. F., Ricco, A. J., Tan, M. X., & Williams, D. E. (2012) · Analytical Chemistry · doi:10.1021/ac2030199 · Cited by 1,194
Effect of pressure development on oxygen consumption by isolated rat heart
Neely, Liebermeister, H., Battersby, E., & Morgan, H. (1967) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1967.212.4.804 · Cited by 1,094
Research works printed but not linked: 3
- Avis FR Investigations of liver and kidney. Design of a dual apparatus for research study Science Teacher 1961 28 1 14 8
- Exton JH Crucible of science: the story of the Cori laboratory 2013 Oxford University Press Oxford
- Markel H Factual Error in: Experiments and observations: how William Beaumont and Alexis St. Martin seized the moment of scientific progress (vol 302, pg 804, 2009) JAMA 2009 302 13 1420 19690317 · DOI
Cited by
Zhang, Y. S., Aleman, J., Shin, S. R., Kilic, T., Kim, D., Mousavi Shaegh, S. A., Massa, S., Riahi, R., Chae, S., Hu, N., et al. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1612906114 · Cited by 833
A decade of progress in tissue engineering
Khademhosseini, A., & Langer, R. (2016) · Nature Protocols · doi:10.1038/nprot.2016.123 · Cited by 747
A multi-organ chip with matured tissue niches linked by vascular flow
Ronaldson-Bouchard, K., Teles, D., Yeager, K., Tavakol, D. N., Zhao, Y., Chramiec, A., Tagore, S., Summers, M., Stylianos, S., Tamargo, M., et al. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00882-6 · Cited by 512
Interconnected Microphysiological Systems for Quantitative Biology and Pharmacology Studies
Edington, C. D., Chen, W. L. K., Geishecker, E., Kassis, T., Soenksen, L. R., Bhushan, B. M., Freake, D., Kirschner, J., Maass, C., Tsamandouras, N., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-22749-0 · Cited by 487
Organ-on-a-chip devices advance to market
Zhang, B., & Radisic, M. (2017) · Lab on a Chip · doi:10.1039/c6lc01554a · Cited by 437
Metadata
- Authors
- Wikswo, J. P.
- Affiliations
- Vanderbilt University (US)
- Corresponding author
- Wikswo, John P
- ORCID
- Wikswo, John P
- Venue
- Experimental Biology and Medicine
- Publisher
- Frontiers Media SA
- Published
- 2014-09
- Volume
- 239
- Issue
- 9
- Pages
- 1061-1072
- ISSN
- 0071-3384 (ISSN-L)
- 1535-3702
- 1535-3699
- PMC
- PMC4330974
- OpenAlex
- W2134377528
- Semantic Scholar
- 7664731d154d9f88432c8bf72c9b9185c0083996
- Cited by
- 248
- References
- 78
- Citations by year
- 2026: 14 · 2025: 20 · 2024: 23 · 2023: 21 · 2022: 15 · 2021: 21 · 2020: 22 · 2019: 21 · 2018: 20 · 2017: 27 · 2016: 28 · 2015: 15 · 2014: 1
- FWCI
- 12.28
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Experimental Biology and Medicine (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institutes of Health (UH3TR000491, UH2TR000491)
- National Center for Advancing Translational Sciences
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Keywords
- microphysiological systems, organ-on-a-chip, in vitro model, physiologically based pharmacokinetic modeling, toxicology, stem cell differentiation, induced pluripotent stem cells, alternatives to animal testing, microbiome, chemical and biological weapons, regulatory science
- MeSH terms
- Adult, Bioprosthesis, Female, Humans, Male, Tissue Engineering
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.