The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Indocyanine Green: Historical Context, Current Applications, and Future Considerations
Abstract
Background. Indocyanine green (ICG) is a dye used in medicine since the mid-1950s for a variety of applications in in cardiology, ophthalmology, and neurosurgery; however, its fluorescent properties have only recently been used in the intraoperative evaluation of tissue perfusion. Method. A literature review was conducted on the characterization and employment of ICG within the medical field. Historical and current context of ICG was examined while also considering implications for its future use. Results. ICG is a relatively nontoxic, unstable compound bound by albumin in the intravascular space until rapid clearance by the liver. It has widespread uses in hepatic, cardiac, and ophthalmologic studies, and its use in analyzing tissue perfusion and identifying sentinel lymph nodes in cancer staging is gaining popularity. Conclusions. ICG has myriad applications and poses low risk to the patient. Its historical uses have contributed to medical knowledge, and it is now undergoing investigation for quantifying tissue perfusion, providing targeted therapies, and intraoperative identification of neurovascular anatomy, ophthalmic structures, and sentinel lymph nodes. New applications of ICG may lead to reduction in postoperative wound-related complications, more effective ophthalmologic procedures, and better detection and treatment of cancer cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Review of Indocyanine Green Fluorescent Imaging in Surgery
Alander, J. T., Kaartinen, I., Laakso, A., Pätilä, T., Spillmann, T., Tuchin, V. V., Venermo, M., & Välisuo, P. (2012) · International Journal of Biomedical Imaging · doi:10.1155/2012/940585 · Cited by 1,352
INDOCYANINE GREEN: OBSERVATIONS ON ITS PHYSICAL PROPERTIES, PLASMA DECAY, AND HEPATIC EXTRACTION*
Cherrick, G. R., Stein, S. W., Leevy, C. M., & Davidson, C. S. (1960) · Journal of Clinical Investigation · doi:10.1172/jci104072 · Cited by 979
Light-absorbing properties, stability, and spectral stabilization of indocyanine green
Landsman, M. L., Kwant, G., Mook, G. A., & Zijlstra, W. G. (1976) · Journal of Applied Physiology · doi:10.1152/jappl.1976.40.4.575 · Cited by 834
Fluorescence Properties and Metabolic Features of Indocyanine Green (ICG) as Related to Angiography
Desmettre, T., Devoisselle, J. M., & Mordon, S. (2000) · Survey of Ophthalmology · doi:10.1016/s0039-6257(00)00123-5 · Cited by 754
Fluorescence navigation with indocyanine green for detecting sentinel lymph nodes in breast cancer
Kitai, T., Inomoto, T., Miwa, M., & Shikayama, T. (2005) · Breast Cancer · doi:10.2325/jbcs.12.211 · Cited by 677
Fluorescence properties of indocyanine green as related to angiography
Benson, R. C., & Kues, H. A. (1978) · Physics in Medicine & Biology · doi:10.1088/0031-9155/23/1/017 · Cited by 432
Rowell, L. B., Blackmon, J. R., & Bruce, R. A. (1964) · Journal of Clinical Investigation · doi:10.1172/jci105043 · Cited by 394 · cited 1×
“Specifically, clearance follows first-order kinetics with the rate of clearance matching the rate of uptake, and at high doses, ICG clearance corresponds with standard Michaelis-Menten enzymatic kinetics.(9,10) The v max of removal is 3.”
ESTIMATION OF HEPATIC BLOOD FLOW WITH INDOCYANINE GREEN*
Leevy, C. M., Mendenhall, C. L., Lesko, W., & Howard, M. M. (1962) · Journal of Clinical Investigation · doi:10.1172/jci104570 · Cited by 380
Near-Infrared Fluorescence Imaging in Humans with Indocyanine Green: A Review and Update
Marshall, M. V., Rasmussen, J. C., Tan, I.-C., Aldrich, M. B., Adams, K. E., Wang, X., Fife, C. E., Maus, E. A., Smith, L. A., & Sevick-Muraca, E. M. (2010) · The Open Surgical Oncology Journal · doi:10.2174/1876504101002010012 · Cited by 341
Jafari, M. D., Lee, K. H., Halabi, W. J., Mills, S. D., Carmichael, J. C., Stamos, M. J., & Pigazzi, A. (2013) · Surgical Endoscopy · doi:10.1007/s00464-013-2832-8 · Cited by 337
Yu, J., Javier, D., Yaseen, M. A., Nitin, N., Richards-Kortum, R., Anvari, B., & Wong, M. S. (2010) · Journal of the American Chemical Society · doi:10.1021/ja908139y · Cited by 312
Indocyanine green-assisted peeling of the internal limiting membrane may cause retinal damage
Gandorfer, A., Haritoglou, C., Gass, C. A., Ulbig, M. W., & Kampik, A. (2001) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(01)01087-x · Cited by 310
Light-Induced Decomposition of Indocyanine Green
Engel, E., Schraml, R., Maisch, T., Kobuch, K., Ko¨nig, B., Szeimies, R.-M., Hillenkamp, J., Ba¨umler, W., & Vasold, R. (2008) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.07-0911 · Cited by 276
Indocyanine Green: Physicochemical Factors Affecting Its Fluorescencein Vivo
Mordon, S., Devoisselle, J. M., Soulie-Begu, S., & Desmettre, T. (1998) · Microvascular Research · doi:10.1006/mvre.1998.2068 · Cited by 268
Marshall, M. V., Rasmussen, J. C., Tan, I.-C., Aldrich, M. B., Adams, K. E., Wang, X., Fife, C. E., Maus, E. A., Smith, L. A., & Sevick-Muraca, E. M. (2010) · The Open Surgical Oncology Journal · doi:10.2174/1876504101002020012 · Cited by 260
Gurtner, G. C., Jones, G. E., Neligan, P. C., Newman, M. I., Phillips, B. T., Sacks, J. M., & Zenn, M. R. (2013) · Annals of Surgical Innovation and Research · doi:10.1186/1750-1164-7-1 · Cited by 256
Indocyanine Green Angiography: A Perspective on Use in the Clinical Setting
Yannuzzi, L. A. (2011) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2011.01.043 · Cited by 235
Photo-oxidative killing of human colonic cancer cells using indocyanine green and infrared light
Bäumler, W., Abels, C., Karrer, S., Weiß, T., Messmann, H., Landthaler, M., & Szeimies, R.-M. (1999) · British Journal of Cancer · doi:10.1038/sj.bjc.6690363 · Cited by 233
An Outcomes Analysis and Satisfaction Survey of 199 Consecutive Abdominoplasties
Hensel, J. M., Lehman, J. A., Tantri, M. P., Parker, M. G., Wagner, D. S., & Topham, N. S. (2001) · Annals of Plastic Surgery · doi:10.1097/00000637-200104000-00001 · Cited by 233
Sentinel lymph node biopsy in breast cancer guided by indocyanine green fluorescence
Murawa, D., Hirche, C. R., Dresel, S. H. J., & Hünerbein, M. (2009) · British journal of surgery · doi:10.1002/bjs.6721 · Cited by 228
KINETICS OF INDOCYANINE GREEN REMOVAL FROM THE BLOOD*
Paumgartner, G., Probst, P., Kraines, R., & Leevy, C. M. (1970) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1970.tb37009.x · Cited by 216
Complications of 278 consecutive abdominoplasties
Stewart, K. J., Stewart, D. A., Coghlan, B., Harrison, D. H., Jones, B. M., & Waterhouse, N. (2006) · Journal of Plastic, Reconstructive & Aesthetic Surgery · doi:10.1016/j.bjps.2005.12.060 · Cited by 214
Near-infrared (NIR) perfusion angiography in minimally invasive colorectal surgery
Ris, F., Hompes, R., Cunningham, C., Lindsey, I., Guy, R., Jones, O., George, B., Cahill, R. A., & Mortensen, N. J. (2014) · Surgical Endoscopy · doi:10.1007/s00464-014-3432-y · Cited by 186
Complications in abdominoplasty: A risk factor analysis
Momeni, A., Heier, M., Bannasch, H., & Stark, G. B. (2009) · Journal of Plastic, Reconstructive & Aesthetic Surgery · doi:10.1016/j.bjps.2008.03.043 · Cited by 173
Osayi, S. N., Wendling, M. R., Drosdeck, J. M., Chaudhry, U. I., Perry, K. A., Noria, S. F., Mikami, D. J., Needleman, B. J., Muscarella, P., Abdel-Rasoul, M., et al. (2015) · Surgical Endoscopy · doi:10.1007/s00464-014-3677-5 · Cited by 164
Optimization of near-infrared fluorescence cholangiography for open and laparoscopic surgery
Verbeek, F. P. R., Schaafsma, B. E., Tummers, Q. R. J. G., van der Vorst, J. R., van der Made, W. J., Baeten, C. I. M., Bonsing, B. A., Frangioni, J. V., van de Velde, C. J. �., Vahrmeijer, A. L., et al. (2013) · Surgical Endoscopy · doi:10.1007/s00464-013-3305-9 · Cited by 156
Indocyanine Green (ICG) Fluorescent Cholangiography During Robotic Cholecystectomy
Daskalaki, D., Fernandes, E., Wang, X., Bianco, F. M., Elli, E. F., Ayloo, S., Masrur, M. A., Milone, L., & Giulianotti, P. C. (2014) · Surgical Innovation · doi:10.1177/1553350614524839 · Cited by 151
Shimada, Y., Okumura, T., Nagata, T., Sawada, S., Matsui, K., Hori, R., Yoshioka, I., Yoshida, T., Osada, R., & Tsukada, K. (2011) · Esophagus · doi:10.1007/s10388-011-0291-7 · Cited by 141
Hirche, C. R., Mohr, Z., Kneif, S., Doniga, S., Murawa, D., Strik, M. W., & Hünerbein, M. (2011) · International Journal of Colorectal Disease · doi:10.1007/s00384-011-1306-5 · Cited by 136
Kanuri, A., Liu, A. S., & Guo, L. (2014) · Plastic & Reconstructive Surgery · doi:10.1097/prs.0000000000000025 · Cited by 118
Biodistribution of Encapsulated Indocyanine Green in Healthy Mice
Yaseen, M. A., Yu, J. Z., Jung, B., Wong, M. S., & Anvari, B. (2009) · Molecular Pharmaceutics · doi:10.1021/mp800270t · Cited by 113
Schols, R. M., Bouvy, N. D., Masclee, A., van Dam, R. M., Dejong, C. H. C., & Stassen, L. P. S. (2012) · Surgical Endoscopy · doi:10.1007/s00464-012-2635-3 · Cited by 102
Near-Infrared Fluorescence Imaging in Patients Undergoing Pancreaticoduodenectomy
Hutteman, M., van der Vorst, J. R., Mieog, J. S. D., Bonsing, B. A., Hartgrink, H. H., Kuppen, P. J. K., Löwik, C. W. G. M., Frangioni, J. V., van de Velde, C. J. �., & Vahrmeijer, A. L. (2011) · European Surgical Research · doi:10.1159/000329411 · Cited by 98
Combined vascular and biliary fluorescence imaging in laparoscopic cholecystectomy
Schols, R. M., Bouvy, N. D., van Dam, R. M., Masclee, A., Dejong, C. H. C., & Stassen, L. P. S. (2013) · Surgical Endoscopy · doi:10.1007/s00464-013-3100-7 · Cited by 96
Kumagai, Y., Ishiguro, T., Haga, N., Kuwabara, K., Kawano, T., & Ishida, H. (2013) · World Journal of Surgery · doi:10.1007/s00268-013-2237-9 · Cited by 89
Tagaya, N., Shimoda, M., Kato, M., Nakagawa, A., Abe, A., Iwasaki, Y., Oishi, H., Shirotani, N., & Kubota, K. (2009) · Journal of Hepato-Biliary-Pancreatic Sciences · doi:10.1007/s00534-009-0195-2 · Cited by 81
Rino, Y., Yukawa, N., Sato, T., Yamamoto, N., Tamagawa, H., Hasegawa, S., Oshima, T., Yoshikawa, T., Masuda, M., & Imada, T. (2014) · BMC Medical Imaging · doi:10.1186/1471-2342-14-18 · Cited by 77
Matsui, A., Winer, J. H., Laurence, R. G., & Frangioni, J. V. (2011) · British Journal of Surgery · doi:10.1002/bjs.7698 · Cited by 69 · cited 1×
“Contrast-tobackground ratios have also been used for the determination of clinical thresholds in intestinal ischemia.(45) However, imaging devices in the current market have differences in excitation wavelengths, filtering, and sensitivities for measuring ICG fluorescence, which may complicate applying one determined…”
MethodSugie, T., Kassim, K., Takeuchi, M., Hashimoto, T., Yamagami, K., Masai, Y., & Toi, M. (2010) · Cancers · doi:10.3390/cancers2020713 · Cited by 68
Kamiya, K., Unno, N., & Konno, H. (2009) · Surgery Today · doi:10.1007/s00595-008-3852-1 · Cited by 63
Iinuma, Y., Hirayama, Y., Yokoyama, N., Otani, T., Nitta, K., Hashidate, H., Yoshida, M., Iida, H., Masui, D., & Manabe, S. (2013) · Journal of Pediatric Surgery · doi:10.1016/j.jpedsurg.2013.03.067 · Cited by 50
Cited by
Visible-to-NIR-Light Activated Release: From Small Molecules to Nanomaterials
Weinstain, R., Slanina, T., Kand, D., & Klán, P. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00663 · Cited by 642
In vivo NIR-II fluorescence imaging for biology and medicine
Wang, F., Zhong, Y., Bruns, O., Liang, Y., & Dai, H. (2024) · Nature Photonics · doi:10.1038/s41566-024-01391-5 · Cited by 564
Photobleaching of organic fluorophores: quantitative characterization, mechanisms, protection *
Demchenko, A. P. (2020) · Methods and Applications in Fluorescence · doi:10.1088/2050-6120/ab7365 · Cited by 370
A chemically stable fluorescent marker of the ureter
Cha, J., Nani, R. R., Luciano, M. P., Kline, G., Broch, A., Kim, K., Namgoong, J.-M., Kulkarni, R. A., Meier, J. L., Kim, P., et al. (2018) · Bioorganic & Medicinal Chemistry Letters · doi:10.1016/j.bmcl.2018.02.040 · Cited by 59
Metadata
- Authors
- Reinhart, M. B., Huntington, C. R., Blair, L. J., Heniford, B. T., & Augenstein, V. A.
- Venue
- Surgical Innovation
- Publisher
- SAGE Publications
- Published
- 2015-09-10
- Volume
- 23
- Issue
- 2
- Pages
- 166-175
- ISSN
- 1553-3506 (ISSN-L)
- 1553-3514
- OpenAlex
- W2322133568
- Cited by
- 517
- References
- 41
- FWCI
- 7.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.