Evaluation of Multiple (3-Cycle) Decontamination Processing for Filtering Facepiece Respirators
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Disposable N95 filtering facepiece respirators (FFRs) certified by the National Institute for Occupational Safety and Health (NIOSH) are widely used by healthcare workers to reduce exposures to infectious biological aerosols. There is currently major concern among public health officials about a possible shortage of N95 FFRs during an influenza pandemic. Decontamination and reuse of FFRs is a possible strategy for extending FFR supplies in an emergency; however, the NIOSH respirator certification process does not currently include provisions for decontamination and reuse. Recent studies have investigated the laboratory performance (filter aerosol penetration and filter airflow resistance) and physical integrity of FFRs following one-cycle (1X) processing of various decontamination treatments. The studies found that a single application of some methods did not adversely affect laboratory performance. In the event that healthcare facilities experience dramatic shortages of FFR supplies, multiple decontamination processing may become necessary. This study investigates three-cycle (3X) processing of eight different methods: ultraviolet germicidal irradiation, ethylene oxide, hydrogen peroxide gas plasma, hydrogen peroxide vapor, microwave-oven-generated steam, bleach, liquid hydrogen peroxide, and moist heat incubation (pasteurization). A four-hour 3X submersion of FFR in deionized water was performed for comparison (control). Following 3X treatment by each decontamination and control method, FFRs were evaluated for changes in physical appearance, odor, and laboratory filtration performance. Only the hydrogen peroxide gas plasma treatment resulted in mean penetration levels > 5% for four of the six FFR models; FFRs treated by the seven other methods and the control samples had expected levels of filter aerosol penetration (< 5%) and filter airflow resistance. Physical damage varied by treatment method. Further research is still needed before any specific decontamination methods can be recommended.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bałazy, A., Toivola, M., Adhikari, A., Sivasubramani, S. K., Reponen, T., & Grinshpun, S. A. (2006) · American Journal of Infection Control · doi:10.1016/j.ajic.2005.08.018 · Cited by 376
Evaluation of Five Decontamination Methods for Filtering Facepiece Respirators
(2009) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/mep070 · Cited by 339 · cited 4×
“Viscusi et al.15 evaluated laboratory performance (filtration efficiency and airflow resistance) of six N95 FFR models and three different P100 models following one-cycle (hereafter referred to as “1X”) processing by five different decontamination methods: ultraviolet germicidal irradiation (UVGI), ethylene oxide (EtO…”
MethodInfluentialPerformance of N95 Respirators: Filtration Efficiency for Airborne Microbial and Inert Particles
Qian, Y., Willeke, K., Grinshpun, S. A., Donnelly, J., & Coffey, C. C. (1998) · American Industrial Hygiene Association Journal · doi:10.1080/15428119891010389 · Cited by 298
Filter Performance of N99 and N95 Facepiece Respirators Against Viruses and Ultrafine Particles
Eninger, R. M., Honda, T., Adhikari, A., Heinonen-Tanski, H., Reponen, T., & Grinshpun, S. A. (2008) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/men019 · Cited by 165
Electrostatic Respirator Filter Media: Filter Efficiency and Most Penetrating Particle Size Effects
Martin, S. B., & Moyer, E. S. (2000) · Applied Occupational and Environmental Hygiene · doi:10.1080/10473220050075617 · Cited by 156
Rengasamy, S., Eimer, B. C., & Shaffer, R. E. (2009) · Annals of Occupational Hygiene · doi:10.1093/annhyg/men086 · Cited by 156
Self-citationRespiratory protection against bioaerosols: Literature review and research needs
Rengasamy, A., Zhuang, Z., & BerryAnn, R. (2004) · American Journal of Infection Control · doi:10.1016/j.ajic.2004.04.199 · Cited by 138
Evaluation of hydrogen peroxide gaseous disinfection systems to decontaminate viruses
Pottage, T., Richardson, C., Parks, S. R., Walker, J. T., & Bennett, A. (2009) · Journal of Hospital Infection · doi:10.1016/j.jhin.2009.08.020 · Cited by 134
Fisher, E. M., & Shaffer, R. E. (2011) · Journal of Applied Microbiology · doi:10.1111/j.1365-2672.2010.04881.x · Cited by 123
Self-citationAerosol Loading Performance of Electret Filter Media
Barrett, L. W., & Rousseau, A. D. (1998) · American Industrial Hygiene Association Journal · doi:10.1080/15428119891010703 · Cited by 112
Cited by
Face Masks in the New COVID-19 Normal: Materials, Testing, and Perspectives
Chua, M. H., Cheng, W., Goh, S. S., Kong, J., Li, B., Lim, J. Y. C., Mao, L., Wang, S., Xue, K., Yang, L., et al. (2020) · Research · doi:10.34133/2020/7286735 · Cited by 495
Rowan, N. J., & Laffey, J. G. (2020) · Science of The Total Environment · doi:10.1016/j.scitotenv.2020.138532 · Cited by 432
Can N95 Respirators Be Reused after Disinfection? How Many Times?
Liao, L., Xiao, W., Zhao, M., Yu, X., Wang, H., Wang, Q., Chu, S., & Cui, Y. (2020) · ACS Nano · doi:10.1021/acsnano.0c03597 · Cited by 431
Managing ICU surge during the COVID-19 crisis: Rapid guidelines.
Aziz, S., Arabi, Y. M., Alhazzani, W., Evans, L., Citerio, G., Fischkoff, K., Salluh, J., Meyfroidt, G., Alshamsi, F., Oczkowski, S., et al. (2020) · Intensive Care Medicine · doi:10.1007/s00134-020-06092-5 · Cited by 380
Rubio-Romero, J. C., Pardo-Ferreira, M. D. C., Torrecilla-García, J. A., & Calero-Castro, S. (2020) · Safety Science · doi:10.1016/j.ssci.2020.104830 · Cited by 281
Lindsley, W. G., Martin, S. B., Thewlis, R. E., Sarkisian, K., Nwoko, J. O., Mead, K. R., & Noti, J. D. (2015) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2015.1018518 · Cited by 240
“Previous studies of the effects of a single cycle or three cycles of lower doses of UVGI on respirators found that the penetration and resistance were not significantly changed.(11,12) The much higher doses of UVGI used in our experiments led to an increase in particle penetration of up to 1.”
BackgroundHeimbuch, B. K., Wallace, W. H., Kinney, K., Lumley, A. E., Wu, C.-Y., Woo, M.-H., & Wander, J. D. (2011) · American Journal of Infection Control · doi:10.1016/j.ajic.2010.07.004 · Cited by 223
“Salter et al(15) reported that chemical offgassing is not a concern for the 3 energetic methods that we studied, and other studies have found that none of the 3 methods significantly affects the particle filtration efficiency of the 6 FFR models that we used in this study.(13,14,16) Fit factor is another concern.”
MethodResultSelf-citationRowan, N. J., & Laffey, J. G. (2021) · Science of The Total Environment · doi:10.1016/j.scitotenv.2020.142259 · Cited by 181
Deng, W., Sun, Y., Yao, X., Subramanian, K., Ling, C., Wang, H., Chopra, S. S., Xu, B. B., Wang, J., Chen, J., et al. (2022) · Advanced Science · doi:10.1002/advs.202102189 · Cited by 160
Can N95 respirators be reused after disinfection? And for how many times?
Liao, L., Xiao, W., Zhao, M., Yu, X., Wang, H., Wang, Q., Chu, S., & Cui, Y. (2020) · doi:10.1101/2020.04.01.20050443 · Cited by 433
Metadata
- Authors
- Bergman, M. S., Viscusi, D. J., Heimbuch, B. K., Wander, J. D., Sambol, A. R., & Shaffer, R. E.
- Venue
- Journal of Engineered Fibers and Fabrics
- Publisher
- SAGE Publications
- Published
- 2010-12
- Volume
- 5
- Issue
- 4
- ISSN
- 1558-9250 (ISSN-L)
- OpenAlex
- W2185567881
- Cited by
- 177
- References
- 17
- FWCI
- 1.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.