Agreement between muscle oxygen saturation from two commercially available systems in endurance running: Moxy Monitor versus Humon Hex
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
Analysis of changes in muscle oxygen saturation (SmO2) in sport settings has become common due to its precise, continuous and non-invasive ability to provide measurements of a particular muscle using near-infrared spectroscopy (NIRS). Therefore, this study aims to determine level of agreement between two affordable NIRS-based oximeter wearable systems for measuring SmO2 level in the vastus lateralis in endurance runners. Seventeen trained endurance male runners (age: 34.2 ± 8.1 years; body mass: 70.5 ± 6.1 kg; height: 1.75 ± 0.04 m; BMI: 23 ± 1.7) completed a submaximal 60-min run-to-exhaustion treadmill running protocol trying to cover the longest possible distance. The SmO2 rates of the vastus lateralis were co-registered and continually obtained from two separate NIRS-based oximeter wearable systems over the running trial. The between-system means comparison reveals no significant differences in SmO2 at any point of the running protocol ( p > 0.217) with trivial-to-small ES (ES 0.624). Additionally, substantial and almost perfect ICCs were obtained (ICC > 0.729). Bland-Altman plots exposed homoscedasticity ( r2 < 0.1) for all the periods analysed during the running protocol, with mean differences lower than 3.2% over the time trial. The results found here show the level of agreement between two economical NIRS-based oximeter wearable systems. Notwithstanding their level of agreement, their interchangeable use is not recommended due to the variation shown for SmO2 levels.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Also, Humon Hex seems to be a good device to measure SmO2 in the vastus lateralis in endurance runners for submaximal 60 min run-to-exhaustion treadmill running test (Jaén-Carrillo et al., 2022).”
From The relationship of muscle oxygen saturation analyzer with other monitoring and quantification tools in a maximal incremental treadmill test (2023) · cites this paper as Jaén-Carrillo et al., 2022
Citations
Cites
The Measurement of Observer Agreement for Categorical Data
Landis, J. R., & Koch, G. G. (1977) · Biometrics · doi:10.2307/2529310 · Cited by 81,148
A guideline of selecting and reporting intraclass correlation coefficients for reliability research
Koo, T. K., & Li, M. Y. (2016) · Journal of Chiropractic Medicine · doi:10.1016/j.jcm.2016.02.012 · Cited by 31,709
Progressive Statistics for Studies in Sports Medicine and Exercise Science
HOPKINS, W. G., MARSHALL, S. W., BATTERHAM, A. M., & HANIN, J. (2009) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31818cb278 · Cited by 9,128 · cited 1×
“0 (almost perfect).(24) Intra class correlation coefficients (ICC) were also calculated between systems.”
MethodCohen, J. (1992) · Current Directions in Psychological Science · doi:10.1111/1467-8721.ep10768783 · Cited by 5,870
Atkinson, G., & Nevill, A. M. (1998) · Sports Medicine · doi:10.2165/00007256-199826040-00002 · Cited by 3,779
Borg's Perceived Exertion and Pain Scales
Heath, E. M. (1998) · Medicine& Science in Sports & Exercise · doi:10.1097/00005768-199809000-00018 · Cited by 3,037
Comparing methods of measurement: why plotting difference against standard method is misleading
Bland, J. M., & Altman, D. G. (1995) · The Lancet · doi:10.1016/s0140-6736(95)91748-9 · Cited by 2,343
Spectroscopy and Imaging with Diffusing Light
Yodh, A., & Chance, B. (1995) · Physics Today · doi:10.1063/1.881445 · Cited by 800 · cited 1×
“900nm and measuring the diffused light to calculate the absorption and dispersion characteristics of the located volume.(6) The HbO and deoxyhaemoglobin (HbR) concentrations in the tissue may be calculated from the spectra of absorption measured.”
BackgroundSeiler, K. S., & Kjerland, G. Ø. (2006) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/j.1600-0838.2004.00418.x · Cited by 643 · cited 1×
“Heart rate, maximum rate of oxygen consumption (VO2max) and blood lactate measurements have been widely used in the past to estimate the training intensity levels to optimise athletic performance.(3,4) Whereas the aforementioned metrics may help guide the training routine of an athlete, these measures are representati…”
BackgroundBlood Lactate Measurements and Analysis during Exercise: A Guide for Clinicians
Goodwin, M. L., Harris, J. E., Hernández, A., & Gladden, L. B. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100414 · Cited by 554
Recovery from exercise-induced desaturation in the quadriceps muscles of elite competitive rowers
Chance, B., Dait, M. T., Zhang, C., Hamaoka, T., & Hagerman, F. (1992) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1992.262.3.c766 · Cited by 528
Van Beekvelt, M. C. P., Colier, W. N. J. M., Wevers, R. A., & Van Engelen, B. G. M. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.90.2.511 · Cited by 430
Wearable Performance Devices in Sports Medicine
Li, R. T., Kling, S. R., Salata, M. J., Cupp, S. A., Sheehan, J., & Voos, J. E. (2016) · Sports Health: A Multidisciplinary Approach · doi:10.1177/1941738115616917 · Cited by 348
Wearable sensors for monitoring the internal and external workload of the athlete
Seshadri, D. R., Li, R. T., Voos, J. E., Rowbottom, J. R., Alfes, C. M., Zorman, C. A., & Drummond, C. K. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0149-2 · Cited by 330
Yu, G., Durduran, T., Lech, G., Zhou, C., Chance, B., Mohler, E. R., & Yodh, A. G. (2005) · Journal of Biomedical Optics · doi:10.1117/1.1884603 · Cited by 230
Muscle Oximetry in Sports Science: A Systematic Review
Perrey, S., & Ferrari, M. (2018) · Sports Medicine · doi:10.1007/s40279-017-0820-1 · Cited by 220 · cited 4×
“laboratory and applied sports settings) has increased due to its reliable, continuous and noninvasive ability to provide a local measurement using NIRS.(5) This technology operates by injecting light into the tissue at a wavelength range between 650 and”
BackgroundMethodInfluentialFamiliarization to treadmill running in young unimpaired adults
Lavcanska, V., Taylor, N. F., & Schache, A. G. (2005) · Human Movement Science · doi:10.1016/j.humov.2005.08.001 · Cited by 214
Validity and reliability of the Moxy oxygen monitor during incremental cycling exercise
Crum, E. M., O'Connor, W. J., Van Loo, L., Valckx, M., & Stannard, S. R. (2017) · European Journal of Sport Science · doi:10.1080/17461391.2017.1330899 · Cited by 206 · cited 5×
“Crum et al.(9) claimed that Moxy Monitor is a reliable system to measure SmO2 at low and moderate intensities, whereas its reliability for such measurements decreases when used at higher intensities.”
BackgroundInfluentialMcManus, C. J., Collison, J., & Cooper, C. E. (2018) · Journal of Biomedical Optics · doi:10.1117/1.jbo.23.1.015007 · Cited by 205 · cited 1×
“MoxZones), it seemed necessary to determine the level of agreement between these two commercially available NIRS-based oximeter wearable systems for SmO2 analysis since previous works found that Moxy Monitor differ from most oximeters when comparing the acquired data.(16,17) Despite the positive findings in SmO2 level…”
ResultFeldmann, A., Schmitz, R. W., & Erlacher, D. (2019) · Journal of Biomedical Optics · doi:10.1117/1.jbo.24.11.115001 · Cited by 203 · cited 5×
“The Moxy Monitor (Fortiori Design, LLC, Hutchinson, MN, USA) has proved its validity and reliability for sports settings.(15) With a size of 6.”
BackgroundMethodResultInfluentialSeshadri, D. R., Drummond, C. K., Craker, J., Rowbottom, J. R., & Voos, J. E. (2017) · IEEE Pulse · doi:10.1109/mpul.2016.2627240 · Cited by 149
Kinematic Accommodation of Novice Treadmill Runners
Schieb, D. A. (1986) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.1986.10605381 · Cited by 148
Farzam, P., Starkweather, Z., & Franceschini, M. A. (2018) · Physiological Reports · doi:10.14814/phy2.13664 · Cited by 107
Asymmetry of quadriceps muscle oxygenation during elite short-track speed skating
HESFORD, C. M., LAING, S. J., CARDINALE, M., & COOPER, C. E. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31822f8942 · Cited by 63
Born, D.-P., Stöggl, T., Swarén, M., & Björklund, G. (2017) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2016-0101 · Cited by 59
Vercruyssen, F., Easthope, C., Bernard, T., Hausswirth, C., Bieuzen, F., Gruet, M., & Brisswalter, J. (2014) · European Journal of Sport Science · doi:10.1080/17461391.2012.730062 · Cited by 58
Jones, B., Dat, M., & Cooper, C. E. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.12.127002 · Cited by 37
Scholkmann, F., & Vrana, A. (2020) · Advances in experimental medicine and biology · doi:10.1007/978-3-030-34461-0_32 · Cited by 17
Cited by
Gandía-Soriano, A., Salas-Montoro, J.-A., Javaloyes, A., Lorente-Casaus, C., Zabala, M., Priego‐Quesada, J. I., & Mateo‐March, M. (2022) · International Journal of Sports Medicine · doi:10.1055/a-1828-8499 · Cited by 18
Osmani, F., Lago-Fuentes, C., Alemany-Iturriaga, J., & Barcala-Furelos, M. (2023) · Frontiers in Physiology · doi:10.3389/fphys.2023.1155037 · Cited by 8
“Also, Humon Hex seems to be a good device to measure SmO2 in the vastus lateralis in endurance runners for submaximal 60 min run-to-exhaustion treadmill running test (Jaén-Carrillo et al., 2022).”
MethodCycling Athlete Performance: Analysis of Muscle Oxygen Saturation through Moxy Measurement
Negara, J. D. K. (2023) · JURNAL PENDIDIKAN JASMANI DAN OLAHRAGA · doi:10.17509/jpjo.v8i1.56177 · Cited by 7
Cinca-Morros, S., Burtscher, M., Benito‐Lopez, F., & Álvarez‐Herms, J. (2025) · Journal of Functional Morphology and Kinesiology · doi:10.3390/jfmk10020220 · Cited by 2
Swimming performance with fins, hand paddles, and parachutes: A systematic review and meta-analysis
Espinosa, D. D., & León-Ariza, H. H. (2025) · Science & Sports · doi:10.1016/j.scispo.2025.06.005 · Cited by 1
Metadata
- Authors
- Jaén-Carrillo, D., Roche-Seruendo, L. E., Cartón-Llorente, A., & García-Pinillos, F.
- Affiliations
- Universidad San Jorge, Zaragoza, Spain
- Universidad San Jorge (ES)
- Department of Physical Education and Sport, University of Granada, Granada, Spain
- Corresponding author
- Cartón-Llorente, Antonio
- Venue
- Proceedings of the Institution of Mechanical Engineers, Part P: Journal of Sports Engineering and Technology
- Publisher
- SAGE Publications
- Published
- 2021-05-05
- Volume
- 236
- Issue
- 3
- Pages
- 231-237
- ISSN
- 1754-3371 (ISSN-L)
- 1754-338X
- OpenAlex
- W3163201870
- Semantic Scholar
- fdccc9bdb9f59334ae6529a9b9c431295f39775e
- Cited by
- 6
- References
- 28
- Citations by year
- 2026: 1 · 2025: 3 · 2023: 1 · 2022: 1
- FWCI
- 0.56
- Type
- journal article
- Language
- en
- Open access
- green
- repositorio.ufro.cl
- Licence
- cc-by-nc-nd
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Proceedings of the Institution of Mechanical Engineers Part P Journal of Sports Engineering and Technology (publishedVersion)
- Omeka S (Universidad de La Frontera) (submittedVersion, cc-by-nc-nd)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Keywords
- muscle oxygen saturation, near-infrared spectroscopy, endurance running, vastus lateralis, device interchangeability
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.