Effects of Pulsatile Subcutaneous Injections of Insulin Lispro on Plasma Insulin Concentration Levels
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Background: Most insulin pumps used for the treatment of diabetes perform subcutaneous insulin injections by pulses. The purpose of this work is to analyze the effects of pulsatile injections of modern insulins on plasma insulin levels compared with a continuous insulin infusion. Method: We simulate pulsatile implementations of a basal rate profile over a day on a type 1 diabetes mellitus patient using insulin lispro. Pulse periods were varied between 1 and 60 min, and random pump errors were included, modeled as white noise, 1/f noise, or 1/f 2 noise with relative standard deviations up to 10% of the pump output. Results: Oscillations in plasma insulin caused by the pulsatile injections were not significant with respect to the global variations for pulse periods below 15 min. This cutoff period was found to be robust to random pump errors with standard deviations up to 10% of the pump output and hence solely determined by the insulin kinetics. Additionally, we showed that the pulse period achieving the best implementation of a continuous profile is an increasing function of the error variance for a given type of noise. Conclusions: Our findings support that continuous insulin infusion can be implemented by a pulsatile injection of insulin as infrequent as a pulse every 15 min without significant effects on plasma insulin levels. If clinically confirmed, this result would have important consequences on the design and in silico testing of automated insulin treatment strategies, as increased delivery intervals imply higher accuracy of insulin delivery and facilitated implementations of closed-loop control algorithms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Meal Simulation Model of the Glucose-Insulin System
Dalla Man, C., Rizza, R. A., & Cobelli, C. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.893506 · Cited by 955
Mudaliar, S. R., Lindberg, F. A., Joyce, M., Beerdsen, P., Strange, P., Lin, A., & Henry, R. R. (1999) · Diabetes Care · doi:10.2337/diacare.22.9.1501 · Cited by 276
GIM, Simulation Software of Meal Glucose–Insulin Model
Dalla Man, C., Raimondo, D. M., Rizza, R. A., & Cobelli, C. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100303 · Cited by 253
Hirsch, I. B., Bode, B. W., Garg, S., Lane, W. S., Sussman, A., Hu, P., Santiago, O. M., Kolaczynski, J. W., & for the Insulin Aspart CSII/MDI Comparison Study Group (2005) · Diabetes Care · doi:10.2337/diacare.28.3.533 · Cited by 197
Models of subcutaneous insulin kinetics. A critical review
Nucci, G., & Cobelli, C. (2000) · Computer Methods and Programs in Biomedicine · doi:10.1016/s0169-2607(00)00071-7 · Cited by 189
Kobayashi, T., Sawano, S., Itoh, T., Kosaka, K., Hirayama, H., & Kasuya, Y. (1983) · Diabetes · doi:10.2337/diab.32.4.331 · Cited by 86
Cited by
Diabetes: Models, Signals, and Control
Cobelli, C., Dalla Man, C., Sparacino, G., Magni, L., De Nicolao, G., & Kovatchev, B. P. (2009) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2009.2036073 · Cited by 511
“Recently, it has been found that, due to the “smoothing” inherent with sc insulin transport, small 15-min insulin boluses are indistinguishable from continuous basal rate [289], which allows designing control algorithms with up to a 15-min actuation rate, an approach that may be superior to the traditional bolus + con…”
Self-citationClosed-loop insulin delivery from bench to clinical practice
Hovorka, R. (2011) · Nature Reviews Endocrinology · doi:10.1038/nrendo.2011.32 · Cited by 342
Kovatchev, B., Cobelli, C., Renard, E., Anderson, S., Breton, M., Patek, S., Clarke, W., Bruttomesso, D., Maran, A., Costa, S., et al. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400611 · Cited by 200
Self-citationKamecke, U., Waldenmaier, D., Haug, C., Ziegler, R., & Freckmann, G. (2019) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818788349 · Cited by 25
Metadata
- Authors
- Chan, A., Breton, M. D., & Kovatchev, B. P.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2008-09
- Volume
- 2
- Issue
- 5
- Pages
- 844-852
- ISSN
- 1932-2968 (ISSN-L)
- OpenAlex
- W2075251541
- Cited by
- 10
- References
- 6
- FWCI
- 0.87
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effects of Pulsatile Subcutaneous Injections of Insulin Lispro on Plasma Insulin Concentration Levels. https://app.cochat.ai/papers/10.1177/193229680800200516
- The paper
- Chan, A., Breton, M. D., & Kovatchev, B. P. (2008). Effects of Pulsatile Subcutaneous Injections of Insulin Lispro on Plasma Insulin Concentration Levels. Journal of Diabetes Science and Technology. https://doi.org/10.1177/193229680800200516
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.