Glucose Meters: A Review of Technical Challenges to Obtaining Accurate Results
Open accessThe DOI matches its Crossref record; 44 of the 45 references it cites were found in a registry or an index, and 1 are not checked yet.
Abstract
Glucose meters are universally utilized in the management of hypoglycemic and hyperglycemic disorders in a variety of healthcare settings. Establishing the accuracy of glucose meters, however, is challenging. Glucose meters can only analyze whole blood, and glucose is unstable in whole blood. Technical accuracy is defined as the closeness of agreement between a test result and the true value of that analyte. Truth for glucose is analysis by isotope dilution mass spectrometry, and frozen serum standards analyzed by this method are available from the National Institute of Standards and Technology. Truth for whole blood has not been established, and cells must be separated from the whole blood matrix before analysis by a method like isotope dilution mass spectrometry. Serum cannot be analyzed by glucose meters, and isotope dilution mass spectrometry is not commonly available in most hospitals and diabetes clinics to evaluate glucose meter accuracy. Consensus standards recommend comparing whole blood analysis on a glucose meter against plasma/serum centrifuged from a capillary specimen and analyzed by a clinical laboratory comparative method. Yet capillary samples may not provide sufficient volume to test by both methods, and venous samples may be used as an alternative when differences between venous and capillary blood are considered. There are thus multiple complexities involved in defining technical accuracy and no clear consensus among standards agencies and professional societies on accuracy criteria. Clinicians, however, are more concerned with clinical agreement of the glucose meter with a serum/plasma laboratory result. Acceptance criteria for clinical agreement vary across the range of glucose concentrations and depend on how the result will be used in screening or management of the patient. A variety of factors can affect glucose meter results, including operator technique, environmental exposure, and patient factors, such as medication, oxygen therapy, anemia, hypotension, and other disease states. This article reviews the challenges involved in obtaining accurate glucose meter results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
National Committee for Clinical Laboratory Standards
Bruck, E. (1980) · Pediatrics · doi:10.1542/peds.65.1.187 · Cited by 14,751
Intensive insulin therapy in the medical ICU
Van den Berghe, G., Wilmer, A., Hermans, G., Meersseman, W., Wouters, P. J., Milants, I., Van Wijngaerden, E., Bobbaers, H., & Bouillon, R. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa052521 · Cited by 3,639
Tietz Textbook of Clinical Chemistry
(1999) · Archives of Pathology and Laboratory Medicine · doi:10.5858/123.7.646b · Cited by 2,495
Capes, S. E., Hunt, D., Malmberg, K., Pathak, P., & Gerstein, H. C. (2001) · Stroke · doi:10.1161/hs1001.096194 · Cited by 1,824
Evaluating clinical accuracy of systems for self-monitoring of blood glucose
Clarke, W. L., Cox, D., Gonder-Frederick, L. A., Carter, W., & Pohl, S. L. (1987) · Diabetes Care · doi:10.2337/diacare.10.5.622 · Cited by 1,435
Standards of Medical Care in Diabetes—2008
Dora, J. M., Kramer, C. K., & Canani, L. H. (2008) · Diabetes Care · doi:10.2337/dc08-0109 · Cited by 1,409
Standards of Medical Care in Diabetes—2008
American Diabetes Association (2008) · Diabetes Care · doi:10.2337/dc08-s012 · Cited by 1,377
Parkes, J. L., Slatin, S. L., Pardo, S., & Ginsberg, B. H. (2000) · Diabetes Care · doi:10.2337/diacare.23.8.1143 · Cited by 620
Vlasselaers, D., Milants, I., Desmet, L., Wouters, P. J., Vanhorebeek, I., van den Heuvel, I., Mesotten, D., Casaer, M. P., Meyfroidt, G., Ingels, C., et al. (2009) · The Lancet · doi:10.1016/s0140-6736(09)60044-1 · Cited by 554
Association of Hyperglycemia with Increased Mortality after Severe Burn Injury
Gore, D. C., Chinkes, D., Heggers, J., Herndon, D. N., Wolf, S. E., & Desai, M. (2001) · Journal of Trauma and Acute Care Surgery · doi:10.1097/00005373-200109000-00021 · Cited by 459
Research works printed but not linked: 9
- Mendosa D. Meter memories. How Tom, Dick, and Charlie did it. Diabetes Wellness Letter. 2000;1(6) [Google Scholar]
- Bernstein RK. London: Little Brown; 1997. Dr. Bernstein's diabetes solution. A complete guide to achieving normal blood sugars. [Google Scholar]
- International Organization for Standardization. ISO/IEC Guide 99. Geneva: International Organization for Standardization; 2007. International vocabulary of metrology—Basic and general concepts and associated terms (VIM) [Google Scholar]
- International Organization for Standardization. Determination of performance criteria for in vitro blood glucose monitoring systems for management of human diabetes mellitus. Geneva: International Organization for Standardization. 2002 ISO 15197. [Google Scholar]
- U.S. Food and Drug Administration. Rockville: Food and Drug Administration. 1989. Review criteria for assessment of portable invasive blood glucose monitoringin vitro diagnostic devices which use glucose oxidase, dehydrogenase, or hexokinase methodology. [Google Scholar]
- Canadian Standards Association. CSA Z316.4-94. Mississauga: Canadian Standards Association. 1994. Performance specifications for portable whole blood glucose monitor systems for use in diabetes management. [Google Scholar]
- Instituto Mexicano del Seguro Social. Mexico City: Instituto Mexicano del Seguro Social. 1998. Reactive strip assessment protocol for determination of glucose in blood. [Google Scholar]
- TNO Center for Medical Technology. Netherlands: TNO Center for Medical Technology; 1991. Quality guideline for non-implantable portable blood glucose monitors for self-monitoring. TNO-CMT/90.021E. [Google Scholar]
- Meneghini LF, Arce RL. Blood glucose data from meter memories often not useful for pattern recognition. Abstract presented at American Diabetes Association 65th Annual Meeting. Diabetes. 2005;54(Suppl 1:A95) [Google Scholar]
Cited by
Items 401–433 of 433
Sarai, E. M., Clarke, T. M., Colton, I. E., Gopinath, A., Roberts, C. N., Huveneers, C. P. M., & Crino, O. L. (2025) · Comparative Biochemistry and Physiology Part A Molecular & Integrative Physiology · doi:10.1016/j.cbpa.2025.111940
Chocron, S. E. (2014) · University Libraries (University of Maryland) · doi:10.13016/m25g7p
The Fast Lane in Diagnostics: Design, Development and Validation of Point-of-Care Systems
Schobesberger, S. (2024) · reposiTUm (TU Wien) · doi:10.34726/hss.2024.120189
Han, J. (2023) · University Libraries (University of Maryland) · doi:10.13016/dspace/pgrf-hinl
Additional file 4 of Substrate specificity mapping of fungal CAZy AA3_2 oxidoreductases
Zhao, H., Karppi, J., Mototsune, O., Poshina, D. N., Svartström, J., Nguyen, T. T. M., Vo, T. M., Tsang, A., Master, E. R., & Tenkanen, M. (2024) · Figshare · doi:10.6084/m9.figshare.26698691
Additional file 1 of Substrate specificity mapping of fungal CAZy AA3_2 oxidoreductases
Zhao, H., Karppi, J., Mototsune, O., Poshina, D. N., Svartström, J., Nguyen, T. T. M., Vo, T. M., Tsang, A., Master, E. R., & Tenkanen, M. (2024) · Figshare · doi:10.6084/m9.figshare.26698682
Additional file 3 of Substrate specificity mapping of fungal CAZy AA3_2 oxidoreductases
Zhao, H., Karppi, J., Mototsune, O., Poshina, D. N., Svartström, J., Nguyen, T. T. M., Vo, T. M., Tsang, A., Master, E. R., & Tenkanen, M. (2024) · Figshare · doi:10.6084/m9.figshare.26698688
Additional file 2 of Substrate specificity mapping of fungal CAZy AA3_2 oxidoreductases
Zhao, H., Karppi, J., Mototsune, O., Poshina, D. N., Svartström, J., Nguyen, T. T. M., Vo, T. M., Tsang, A., Master, E. R., & Tenkanen, M. (2024) · Figshare · doi:10.6084/m9.figshare.26698685
Additional file 5 of Substrate specificity mapping of fungal CAZy AA3_2 oxidoreductases
Zhao, H., Karppi, J., Mototsune, O., Poshina, D. N., Svartström, J., Nguyen, T. T. M., Vo, T. M., Tsang, A., Master, E. R., & Tenkanen, M. (2024) · Figshare · doi:10.6084/m9.figshare.26698694
Utvärdering av blodsockermätarna Accu-Chek Aviva och gPet \nPLUS för kattprover
Witthuhn, K. (2021) · Epsilon Archive for Student Projects (Swedish University of Agricultural Sciences)
Mesoporous nanoarchitectures for electrochemical biosensors
Fornerod, M. J. J. (2023) · UCL Discovery (University College London)
Evaluating “Cowboy Challenge,” a Worksite Wellness Program of Oklahoma State University
Hooks, A. (2017) · SHAREOK (University of Oklahoma; Oklahoma State University; Central Oklahoma University) · Cited by 1
Škarda, J. (2021) · Digital Library (University of West Bohemia) · Cited by 1
Akbar, M. A., Parwati, P. A., & Sanjiwani, A. A. S. (2025) · Zenodo (CERN European Organization for Nuclear Research) · doi:10.5281/zenodo.17116013
Emerging Trends in Portable Analytical Devices (Miniaturized Systems) for Food Adulteration Analysis
Koumbia, M., Agbevohia, K. A., Diantom, A., & Aly, M. A. S. (2025) · Springer eBooks · doi:10.1007/978-3-031-99454-8_12
Design Project of Medical Equipment with Artificial Intelligence
Melikyan, A., Atsharyan, A., Baghdasaryan, A., Petrosyan, A., Petrosyan, L., & Paytyan, T. (2026) · International Research Journal of Multidisciplinary Scope · doi:10.47857/irjms.2026.v07i01.07244
Wavelength-Dependent Optical Sensing of Glucose in Aqueous Solution Supported by Machine Learning
Hamdy, O., Abo-Zahhad, M. M., Hany, N., Elsayed, M., & Abo-Zahhad, M. M. (2026) · Sensing and Imaging · doi:10.1007/s11220-025-00714-2
Naeeni, S. S., Bambai, B., Yakhchali, B., Saffarian, P., & Minuchehr, Z. (2026) · CyTA - Journal of Food · doi:10.1080/19476337.2026.2623742
Deviche, P., Upah, N., Watts, L., & Sweazea, K. L. (2026) · Journal of Avian Medicine and Surgery · doi:10.1647/avianms-d-24-00057
Validity of Glucose Measurement Methods During Surgery: A Systematic Review
Heatlie, L. C., Ejaredar, M., Lithgow, K. C., Dillane, D., Manek, R., Gill, S., Cameron, A. T., Füzéry, A. K., Pham, M. M., Subramanian, A., et al. (2026) · Canadian Journal of Diabetes · doi:10.1016/j.jcjd.2026.04.002
Comparability of venous versus capillary hemoglobin A1c measurements
Yunir, E., Wafa, S., Indrasari, N. D., Iswati, E., Christabel, E. V., Widiyanti, D., Wisnu, W., Kurniawan, F., Amalina, N., Pradnjaparamita, T., et al. (2026) · Diabetology International · doi:10.1007/s13340-026-00889-3
Moarref, M. P., Black, W., & Chen, Y. (2026) · Diagnostics · doi:10.3390/diagnostics16091383
Noninvasive Blood Glucose Monitoring with Machine Learning Enhanced Transmittance Spectroscopy
Paul, T. K., Nayem, S. S., Rakib, M. A., Islam, M. J., Kaysir, M. R., & Rassel, S. (2026) · ACS Omega · doi:10.1021/acsomega.5c11682
Assisted Devices and Daily Life Adaptations in Diabetes
Das, U., Roy, D., Singh, S., & Mandal, S. (2026) · Springer eBooks · doi:10.1007/978-981-95-8946-3_13
Menetelmävertailu vieritutkimuslaitteen hankintaprosessissa
Portimo, E. (2026) · Theseus (Ammattikorkeakoulujen)
Educational Video on Capillary Blood Glucose Measurement: Development and ValidationPreprint
Diogo, R. C. D. S., Liberatori, R. D. S. M., Neto, J. C. D. S., Souto, K. D. O. L., & Nogueira, P. C. (2026) · Preprints.org · doi:10.20944/preprints202606.1498.v1
Pooja, P. R., Narasannavar, A., & Koppad, R. (2026) · National Journal of Community Medicine · doi:10.55489/njcm.170720266659
Kaczmarski, M., Kamiński, P., Surdacka, L., Jagiełło, J. K., Jakubas, A., Iwanicka, K. A., Pawelec, K., & Jóźwiak, S. M. (2026) · International Journal of Innovative Technologies in Social Science · doi:10.31435/ijitss.2(50).2026.5663
Lee, A., & Cao, L. (2026) · The Journal of Applied Laboratory Medicine · doi:10.1093/jalm/jfag144
Physical Process Involved in the Recognition of Ions via Optical Chemosensors: A Concise Report
Khan, D., Maurya, N., Shaily, Bisht, S., Singh, N., & Kushwaha, P. (2026) · Journal of Analytical Chemistry · doi:10.1134/s1061934825604116
Azurduy, C., Paredes, E., Delgadillo, E., Arteaga, B., Paniagua, L., & Barbosa, N. (2019) · Universidad-Ciencia-&-Sociedad · doi:10.61070/ucs.v21i2.33
Jiménez-Rodríguez, M., Sainz-Calvo, Á. J., García‐Guzmán, J. J., Aguilera, L. C., Santander, J. M. P., & Bellido-Milla, D. (2026) · Talanta · doi:10.1016/j.talanta.2026.130875
Metadata
- Authors
- Tonyushkina, K., & Nichols, J. H.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2009-07
- Volume
- 3
- Issue
- 4
- Pages
- 971-980
- ISSN
- 1932-2968 (ISSN-L)
- OpenAlex
- W2112149778
- Cited by
- 406
- References
- 44
- FWCI
- 6.30
- Type
- journal article
- Language
- en
- Open access
- green
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.