Glucose Meters: A Review of Technical Challenges to Obtaining Accurate Results
Open accessThe DOI matches its Crossref record; 44 of the 45 references it cites were found in a registry or an index, and 1 are not checked yet.
Abstract
Glucose meters are universally utilized in the management of hypoglycemic and hyperglycemic disorders in a variety of healthcare settings. Establishing the accuracy of glucose meters, however, is challenging. Glucose meters can only analyze whole blood, and glucose is unstable in whole blood. Technical accuracy is defined as the closeness of agreement between a test result and the true value of that analyte. Truth for glucose is analysis by isotope dilution mass spectrometry, and frozen serum standards analyzed by this method are available from the National Institute of Standards and Technology. Truth for whole blood has not been established, and cells must be separated from the whole blood matrix before analysis by a method like isotope dilution mass spectrometry. Serum cannot be analyzed by glucose meters, and isotope dilution mass spectrometry is not commonly available in most hospitals and diabetes clinics to evaluate glucose meter accuracy. Consensus standards recommend comparing whole blood analysis on a glucose meter against plasma/serum centrifuged from a capillary specimen and analyzed by a clinical laboratory comparative method. Yet capillary samples may not provide sufficient volume to test by both methods, and venous samples may be used as an alternative when differences between venous and capillary blood are considered. There are thus multiple complexities involved in defining technical accuracy and no clear consensus among standards agencies and professional societies on accuracy criteria. Clinicians, however, are more concerned with clinical agreement of the glucose meter with a serum/plasma laboratory result. Acceptance criteria for clinical agreement vary across the range of glucose concentrations and depend on how the result will be used in screening or management of the patient. A variety of factors can affect glucose meter results, including operator technique, environmental exposure, and patient factors, such as medication, oxygen therapy, anemia, hypotension, and other disease states. This article reviews the challenges involved in obtaining accurate glucose meter results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
National Committee for Clinical Laboratory Standards
Bruck, E. (1980) · Pediatrics · doi:10.1542/peds.65.1.187 · Cited by 14,751
Intensive insulin therapy in the medical ICU
Van den Berghe, G., Wilmer, A., Hermans, G., Meersseman, W., Wouters, P. J., Milants, I., Van Wijngaerden, E., Bobbaers, H., & Bouillon, R. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa052521 · Cited by 3,639
Tietz Textbook of Clinical Chemistry
(1999) · Archives of Pathology and Laboratory Medicine · doi:10.5858/123.7.646b · Cited by 2,495
Capes, S. E., Hunt, D., Malmberg, K., Pathak, P., & Gerstein, H. C. (2001) · Stroke · doi:10.1161/hs1001.096194 · Cited by 1,824
Evaluating clinical accuracy of systems for self-monitoring of blood glucose
Clarke, W. L., Cox, D., Gonder-Frederick, L. A., Carter, W., & Pohl, S. L. (1987) · Diabetes Care · doi:10.2337/diacare.10.5.622 · Cited by 1,435
Standards of Medical Care in Diabetes—2008
Dora, J. M., Kramer, C. K., & Canani, L. H. (2008) · Diabetes Care · doi:10.2337/dc08-0109 · Cited by 1,409
Standards of Medical Care in Diabetes—2008
American Diabetes Association (2008) · Diabetes Care · doi:10.2337/dc08-s012 · Cited by 1,377
Parkes, J. L., Slatin, S. L., Pardo, S., & Ginsberg, B. H. (2000) · Diabetes Care · doi:10.2337/diacare.23.8.1143 · Cited by 620
Vlasselaers, D., Milants, I., Desmet, L., Wouters, P. J., Vanhorebeek, I., van den Heuvel, I., Mesotten, D., Casaer, M. P., Meyfroidt, G., Ingels, C., et al. (2009) · The Lancet · doi:10.1016/s0140-6736(09)60044-1 · Cited by 554
Association of Hyperglycemia with Increased Mortality after Severe Burn Injury
Gore, D. C., Chinkes, D., Heggers, J., Herndon, D. N., Wolf, S. E., & Desai, M. (2001) · Journal of Trauma and Acute Care Surgery · doi:10.1097/00005373-200109000-00021 · Cited by 459
Research works printed but not linked: 9
- Mendosa D. Meter memories. How Tom, Dick, and Charlie did it. Diabetes Wellness Letter. 2000;1(6) [Google Scholar]
- Bernstein RK. London: Little Brown; 1997. Dr. Bernstein's diabetes solution. A complete guide to achieving normal blood sugars. [Google Scholar]
- International Organization for Standardization. ISO/IEC Guide 99. Geneva: International Organization for Standardization; 2007. International vocabulary of metrology—Basic and general concepts and associated terms (VIM) [Google Scholar]
- International Organization for Standardization. Determination of performance criteria for in vitro blood glucose monitoring systems for management of human diabetes mellitus. Geneva: International Organization for Standardization. 2002 ISO 15197. [Google Scholar]
- U.S. Food and Drug Administration. Rockville: Food and Drug Administration. 1989. Review criteria for assessment of portable invasive blood glucose monitoringin vitro diagnostic devices which use glucose oxidase, dehydrogenase, or hexokinase methodology. [Google Scholar]
- Canadian Standards Association. CSA Z316.4-94. Mississauga: Canadian Standards Association. 1994. Performance specifications for portable whole blood glucose monitor systems for use in diabetes management. [Google Scholar]
- Instituto Mexicano del Seguro Social. Mexico City: Instituto Mexicano del Seguro Social. 1998. Reactive strip assessment protocol for determination of glucose in blood. [Google Scholar]
- TNO Center for Medical Technology. Netherlands: TNO Center for Medical Technology; 1991. Quality guideline for non-implantable portable blood glucose monitors for self-monitoring. TNO-CMT/90.021E. [Google Scholar]
- Meneghini LF, Arce RL. Blood glucose data from meter memories often not useful for pattern recognition. Abstract presented at American Diabetes Association 65th Annual Meeting. Diabetes. 2005;54(Suppl 1:A95) [Google Scholar]
Cited by
Exercise management in type 1 diabetes: a consensus statement
Riddell, M. C., Gallen, I. W., Smart, C. E., Taplin, C. E., Adolfsson, P., Lumb, A. N., Kowalski, A., Rabasa-Lhoret, R., McCrimmon, R. J., Hume, C., et al. (2017) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(17)30014-1 · Cited by 903
Device integration of electrochemical biosensors
Wu, J., Liu, H., Chen, W., Ma, B., & Ju, H. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00032-w · Cited by 895
The Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring System
Bailey, T., Bode, B. W., Christiansen, M. P., Klaff, L. J., & Alva, S. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0378 · Cited by 685
“Sources contributing to differences between capillary BG versus venous YSI readings include the amount of blood used for testing, delays in analysis from the time of sampling, and differences in the composition of the blood samples.(9,10) Collectively, these differences limit the direct comparison of accuracy outcomes…”
BackgroundMethodA history of blood glucose meters and their role in self-monitoring of diabetes mellitus
Clarke, S. F., & Foster, J. R. (2012) · British Journal of Biomedical Science · doi:10.1080/09674845.2012.12002443 · Cited by 456
Wearable Electrochemical Glucose Sensors in Diabetes Management: A Comprehensive Review
Saha, T., Del Caño, R., Mahato, K., De la Paz, E., Chen, C., Ding, S., Yin, L., & Wang, J. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00078 · Cited by 442
Surface-enhanced Raman spectroscopy for in vivo biosensing
Laing, S., Jamieson, L. E., Faulds, K., & Graham, D. (2017) · Nature Reviews Chemistry · doi:10.1038/s41570-017-0060 · Cited by 442
Universal mobile electrochemical detector designed for use in resource-limited applications
Nemiroski, A., Christodouleas, D. C., Hennek, J. W., Kumar, A. A., Maxwell, E. J., Fernández-Abedul, M. T., & Whitesides, G. M. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1405679111 · Cited by 285
Recent advances in 3D printing technologies for wearable (bio)sensors
Kalkal, A., Kumar, S., Kumar, P., Pradhan, R., Willander, M., Packirisamy, G., Kumar, S., & Malhotra, B. D. (2021) · Additive Manufacturing · doi:10.1016/j.addma.2021.102088 · Cited by 232
Continuous glucose monitoring: an Endocrine Society Clinical Practice Guideline
Klonoff, D. C., Buckingham, B., Christiansen, J. S., Montori, V. M., Tamborlane, W. V., Vigersky, R. A., & Wolpert, H. (2011) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2010-2756 · Cited by 211
Pullano, S. A., Greco, M., Bianco, M. G., Foti, D., Brunetti, A., & Fiorillo, A. S. (2022) · Theranostics · doi:10.7150/thno.64035 · Cited by 210
“, venous samples collected in lithium heparin containing tubes) [54,55].”
BackgroundColorimetric sensing for translational applications: from colorants to mechanisms
Jin, Z., Yim, W., Retout, M., Housel, E., Zhong, W., Zhou, J., Strano, M. S., & Jokerst, J. V. (2024) · Chemical Society Reviews · doi:10.1039/d4cs00328d · Cited by 206
Yetisen, A. K., Butt, H., Volpatti, L. R., Pavlichenko, I., Humar, M., Kwok, S. J. J., Koo, H., Kim, K. S., Naydenova, I., Khademhosseini, A., et al. (2016) · Biotechnology Advances · doi:10.1016/j.biotechadv.2015.10.005 · Cited by 192
Guidelines and Considerations for Metabolic Tolerance Tests in Mice
Benedé-Ubieto, R., Estévez-Vázquez, O., Ramadori, P., Cubero, F. J., & Nevzorova, Y. A. (2020) · Diabetes, Metabolic Syndrome and Obesity: Targets and Therapy · doi:10.2147/dmso.s234665 · Cited by 172
“Therefore, overnight fasting provokes a catabolic Table 1 Bullet Points: General Experimental Pre-Settings, Quick Procedure and Considerations for MTT Experimental Pre-Settings ● Quiet and stress-free environment ● Standardized and persistent conditions through the whole experi- mental period (i.e. time of fasting, ro…”
BackgroundInfluentialChallenges and perspectives in continuous glucose monitoring
van Enter, B. J., & von Hauff, E. (2018) · Chemical Communications · doi:10.1039/c8cc01678j · Cited by 154
Noninvasive Electromagnetic Wave Sensing of Glucose
Zhang, R., Liu, S., Jin, H., Luo, Y., Zheng, Z., Gao, F., & Zheng, Y. (2019) · Sensors · doi:10.3390/s19051151 · Cited by 154
Investigation of the Accuracy of 18 Marketed Blood Glucose Monitors
Klonoff, D. C., Parkes, J. L., Kovatchev, B. P., Kerr, D., Bevier, W. C., Brazg, R. L., Christiansen, M., Bailey, T. S., Nichols, J. H., & Kohn, M. A. (2018) · Diabetes Care · doi:10.2337/dc17-1960 · Cited by 144
“Many factors affect the accuracy of a BGM, including those related to the test strip and the meter (14,15).”
BackgroundSelf-citationThe Accuracy of Point-of-Care Glucose Measurements
Rebel, A., Rice, M. A., & Fahy, B. G. (2012) · Journal of Diabetes Science and Technology · doi:10.1177/193229681200600228 · Cited by 144
Continuous Glucose Monitoring: Review of an Innovation in Diabetes Management
Mian, Z., Hermayer, K. L., & Jenkins, A. (2019) · The American Journal of the Medical Sciences · doi:10.1016/j.amjms.2019.07.003 · Cited by 139
Shokrekhodaei, M., Cistola, D. P., Roberts, R. C., & Quiñones, S. (2021) · IEEE Access · doi:10.1109/access.2021.3079182 · Cited by 146
Glucose Oxidase-Instructed Fluorescence Amplification Strategy for Intracellular Glucose Detection
Jiang, S., Zhang, Y., Yang, Y., Huang, Y., Ma, G., Luo, Y., Huang, P., & Lin, J. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b00010 · Cited by 129
Wei, X., Guo, J., Lian, H., Sun, X., & Liu, B. (2020) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2020.129205 · Cited by 130
Comparative accuracy of 17 point-of-care glucose meters
Ekhlaspour, L., Mondesir, D., Lautsch, N., Balliro, C., Hillard, M., Magyar, K., Radocchia, L. G., Esmaeili, A., Sinha, M., & Russell, S. J. (2017) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816672237 · Cited by 127
Recent Advances of Optical Sensors for Copper Ion Detection
Gerdan, Z., Saylan, Y., & Denizli, A. (2022) · Micromachines · doi:10.3390/mi13081298 · Cited by 122
Interferences and Limitations in Blood Glucose Self-Testing: An Overview of the Current Knowledge
Erbach, M., Freckmann, G., Hinzmann, R., Kulzer, B., Ziegler, R., Heinemann, L., & Schnell, O. (2016) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816641433 · Cited by 115
“Inappropriate handling of SMBG has been identified as the most common factor affecting BG results; more than 90% of overall inaccuracies result from incorrect use of BG meters.(4,18) Due to the minute blood samples utilized by mod-”
BackgroundInfluentialLan, T., Zhang, J., & Lu, Y. (2016) · Biotechnology Advances · doi:10.1016/j.biotechadv.2016.03.002 · Cited by 111
Biosensors for Public Health and Environmental Monitoring: The Case for Sustainable Biosensing
Williams, A., Aguilar, M. R., Arachchillage, K. P., Chandra, S., Rangan, S., Gupta, S. G., & Artés, J. M. (2024) · ACS Sustainable Chemistry & Engineering · doi:10.1021/acssuschemeng.3c06112 · Cited by 121
Petryayeva, E., & Algar, W. R. (2015) · RSC Advances · doi:10.1039/c4ra15036h · Cited by 123
A Nanotechnology-Based Approach to Biosensor Application in Current Diabetes Management Practices
Shoaib, A., Darraj, A., Khan, M. E., Azmi, L., Alalwan, A., Alamri, O., Tabish, M., & Khan, A. U. (2023) · Nanomaterials · doi:10.3390/nano13050867 · Cited by 116
Czupryniak, L., Barkai, L., Bolgarska, S., Bronisz, A., Broz, J., Cypryk, K., Honka, M., Janez, A., Krnic, M., Lalic, N., et al. (2014) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2013.0302 · Cited by 93
Klonoff, D. C., Blonde, L., Cembrowski, G., Chacra, A. R., Charpentier, G., Colagiuri, S., Dailey, G., Gabbay, R. A., Heinemann, L., Kerr, D., et al. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500630 · Cited by 97
Choudhary, T., Rajamanickam, G. P., & Dendukuri, D. (2015) · Lab on a Chip · doi:10.1039/c5lc00041f · Cited by 96
Glucose oxidase-based biosensor for glucose detection from biological fluids
Mandpe, P., Prabhakar, B. R., Gupta, H., & Shende, P. K. (2020) · Sensor Review · doi:10.1108/sr-01-2019-0017 · Cited by 95
Lopes, L. C., Santos, A., & Bueno, P. R. (2022) · Sensors and Actuators Reports · doi:10.1016/j.snr.2022.100087 · Cited by 91
Márquez, A., Jiménez‐Jorquera, C., Domínguez, C., & Muñoz‐Berbel, X. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.05.051 · Cited by 92
Zhang, J., & Lu, Y. (2018) · Angewandte Chemie International Edition · doi:10.1002/anie.201804292 · Cited by 87
A machine learning-based on-demand sweat glucose reporting platform
Sankhala, D., Sardesai, A. U., Pali, M. L., Lin, K., Jagannath, B., Muthukumar, S., & Prasad, S. (2022) · Scientific Reports · doi:10.1038/s41598-022-06434-x · Cited by 91
Poudel, S., Tsunemoto, H., Seif, Y., Sastry, A. V., Szubin, R., Xu, S., Machado, H., Olson, C. A., Anand, A., Pogliano, J., et al. (2020) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2008413117 · Cited by 90
Ling, J., Ng, J. K., Chan, J. C. N., & Chow, E. (2022) · Frontiers in Endocrinology · doi:10.3389/fendo.2022.869899 · Cited by 88
MOF-based nanocomposites as transduction matrices for optical and electrochemical sensing
Shubhangi, S., Nandi, I., Rai, S., & Chandra, P. (2023) · Talanta · doi:10.1016/j.talanta.2023.125124 · Cited by 82
Pioglitazone Prevents Diabetes in Patients With Insulin Resistance and Cerebrovascular Disease
Inzucchi, S. E., Viscoli, C. M., Young, L. H., Furie, K. L., Gorman, M., Lovejoy, A. M., Dagogo-Jack, S., Ismail-Beigi, F., Korytkowski, M. T., Pratley, R. E., et al. (2016) · Diabetes Care · doi:10.2337/dc16-0798 · Cited by 75
Point-of-Care Testing: Future of Chronic Disease State Management?
Goble, J. A., & Rocafort, P. T. (2015) · Journal of Pharmacy Practice · doi:10.1177/0897190015587696 · Cited by 76
Capillary blood for point-of-care testing
Tang, R., Yang, H., Choi, J. R., Gong, Y. M., You, M., Wen, T., Li, A., Li, X., Xu, B., Zhang, S., et al. (2017) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408363.2017.1343796 · Cited by 79
Cortes, F. R., Falomir, E., Láncis, J., & Mínguez-Vega, G. (2024) · Applied Surface Science · doi:10.1016/j.apsusc.2024.160326 · Cited by 70
Priya, M., Anjana, R. M., Pradeepa, R., Jayashri, R., Deepa, M., Bhansali, A., & Mohan, V. (2011) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2010.0218 · Cited by 75
Bhavadharini, B., Mahalakshmi, M. M., Maheswari, K., Kalaiyarasi, G., Anjana, R. M., Deepa, M., Ranjani, H., Priya, M., Uma, R., Sriram, U., et al. (2015) · Acta Diabetologica · doi:10.1007/s00592-015-0761-9 · Cited by 63
Electrospinning applications from diagnosis to treatment of diabetes
Vellayappan, M. V., Venugopal, J. R., Ramakrishna, S., Ray, S. S., Ismail, A. F., Mandal, M., Manikandan, A., Seal, S., & Jaganathan, S. K. (2016) · RSC Advances · doi:10.1039/c6ra15252j · Cited by 120
Assisted Monitoring of Blood Glucose: Special Safety Needs for a New Paradigm in Testing Glucose
Klonoff, D. C., & Perz, J. F. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400501 · Cited by 62
CuO/Cu/rGO nanocomposite anodic titania nanotubes for boosted non-enzymatic glucose biosensors
Chahrour, K. M., Ooi, P. C., Nazeer, A. A., Al-Hajji, L. A., Jubu, P. R., Dee, C. F., Ahmadipour, M., & Hamzah, A. A. (2023) · New Journal of Chemistry · doi:10.1039/d3nj00666b · Cited by 60
Fu, L., Qi, C., Sun, T., Huang, K., Lin, J., & Huang, P. (2023) · Exploration · doi:10.1002/exp.20210110 · Cited by 59
A Gel-Based Separation-Free Point-of-Care Device for Whole Blood Glucose Detection
Dai, J. H., Zhang, H., Huang, C. Y., Chen, Z., & Han, A. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c03801 · Cited by 57
Gerber, K. L., & Freeman, K. P. (2016) · Veterinary Clinical Pathology · doi:10.1111/vcp.12310 · Cited by 62
Issues in the practical implementation of POCT: overcoming challenges
Wiencek, J. R., & Nichols, J. H. (2016) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.2016.1141678 · Cited by 55
Self-citationChen, Q., Fu, Y., Zhang, W., Ye, S.-B., Zhang, H., Xie, F., Gong, L., Wei, Z., Jin, H., & Chen, J. (2016) · Talanta · doi:10.1016/j.talanta.2016.12.076 · Cited by 55
Zhang, X., Sucre‐Rosales, E., Byram, A., Hernandez, F. E., & Chen, G. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.0c16369 · Cited by 54
Historical perspectives in clinical pathology: a history of glucose measurement
Moodley, N., Ngxamngxa, U., Turzyniecka, M. J., & Pillay, T. S. (2015) · Journal of Clinical Pathology · doi:10.1136/jclinpath-2014-202672 · Cited by 56
Bragg, F., Li, L., Yang, L., Yu, C., Chen, Y., Bian, Z., Chen, J., Collins, R., Peto, R., Wang, C., et al. (2016) · PLoS Medicine · doi:10.1371/journal.pmed.1002026 · Cited by 54
Fluorescent Sensor Array for Quantitative Determination of Saccharides
Pushina, M., Penavic, A., Farshbaf, S., & Anzenbacher, P. (2021) · ACS Sensors · doi:10.1021/acssensors.1c01371 · Cited by 52
Sharma, A., Tok, A. I. Y., Palaniappan, A., & Liedberg, B. (2021) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2021.116327 · Cited by 53
Practical Considerations When Prescribing Icodextrin: A Narrative Review
Silver, S. A., Harel, Z., & Perl, J. M. (2014) · American Journal of Nephrology · doi:10.1159/000363417 · Cited by 50
164 Undiagnosed diabetes mellitus in rural communities in Sudan: prevalence and risk factors
Noor, S. K., Bushara, S. O., Sulaiman, A. A., Elmadhoun, W. M., & Ahmed, M. H. (2015) · Eastern Mediterranean Health Journal · doi:10.26719/2015.21.3.164 · Cited by 53
Benchmarking Glycemic Control In U.S. Hospitals
Bersoux, S., Cook, C. B., Kongable, G. L., Shu, J., & Zito, D. R. (2014) · Endocrine Practice · doi:10.4158/ep13516.or · Cited by 50
Klaff, L. J., Brazg, R., Hughes, K., Tideman, A. M., Schachner, H. C., Stenger, P., Pardo, S., Dunne, N., & Parkes, J. L. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0069 · Cited by 46
Musholt, P. B., Schipper, C., Thomé, N., Ramljak, S., Schmidt, M., Forst, T., & Pfützner, A. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500520 · Cited by 46
Motion-based glucose sensing based on a fish-like enzymeless motor
Li, M., Zhang, H., Liu, M., & Dong, B. (2017) · Journal of Materials Chemistry C · doi:10.1039/c7tc01122a · Cited by 46
Blood Glucose Measurement in the Intensive Care Unit: What is the Best Method?
Le, H. T., Harris, N., Estilong, A. J., Olson, A., & Rice, M. J. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700226 · Cited by 44
Jazi, H. K., Sarafbidabad, M., Henda, M. B., & Ahmadipour, M. (2024) · Diamond and Related Materials · doi:10.1016/j.diamond.2024.111845 · Cited by 46
Shatwan, I. M., Ahmed, L. A., & Badkook, M. (2013) · Journal of Medicinal Food · doi:10.1089/jmf.2012.0083 · Cited by 46
Electrochemical Aptamer-Based Biosensors for Measurements in Undiluted Human Saliva
Nguyen, M., Nguyen, K.-N., Malo, S., Banerjee, I., Wu, D., Du‐Thumm, L., & Dauphin‐Ducharme, P. (2023) · ACS Sensors · doi:10.1021/acssensors.3c01624 · Cited by 42
Glucose measurement in body fluids: A ready reckoner for clinicians
Kubihal, S., Goyal, A., Gupta, Y., & Khadgawat, R. (2020) · Diabetes & Metabolic Syndrome Clinical Research & Reviews · doi:10.1016/j.dsx.2020.11.021 · Cited by 47
Validity and Reliability of a Glucometer Against Industry Reference Standards
Salacinski, A. J., Alford, M., Drevets, K., Hart, S., & Hunt, B. E. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296813514315 · Cited by 47
Petritz, O. A., Antinoff, N., Chen, S., Kass, P. H., & Paul‐Murphy, J. (2013) · Journal of the American Veterinary Medical Association · doi:10.2460/javma.242.3.350 · Cited by 43
Birru, E. M., Abdelwuhab, M., & Shewamene, Z. (2015) · BMC Complementary and Alternative Medicine · doi:10.1186/s12906-015-0852-8 · Cited by 42
RSSDI consensus on self-monitoring of blood glucose in types 1 and 2 diabetes mellitus in India
Rao, P., Makkar, B. M., Kumar, A., Das, A. K., Singh, A. K., Mithal, A., Bhansali, A., Misra, A., Maheshwari, A., Gupta, A., et al. (2018) · International Journal of Diabetes in Developing Countries · doi:10.1007/s13410-018-0677-3 · Cited by 49
Gate-controlled graphene surface plasmon resonance glucose sensor
Hossain, M. M., & Talukder, M. A. (2021) · Optics Communications · doi:10.1016/j.optcom.2021.126994 · Cited by 39
Guati, C., Gómez‐Coma, L., Fallanza, M., & Ortíz, I. (2023) · Reviews in Chemical Engineering · doi:10.1515/revce-2022-0058 · Cited by 39
Whole body heat exposure modulates acute glucose metabolism
Kimball, A., McCue, P. M., Petrie, M. A., & Shields, R. K. (2018) · International Journal of Hyperthermia · doi:10.1080/02656736.2018.1516303 · Cited by 40
Kumi, M., Wang, T., Ejeromedoghene, O., Wang, J., Li, P., & Huang, W. (2024) · Small Methods · doi:10.1002/smtd.202301341 · Cited by 39
Bocu, R. (2024) · Biosensors · doi:10.3390/bios14050214 · Cited by 42
Adamson, T., Eusebio, F. A., Cook, C. B., & Belle, J. T. L. (2012) · The Analyst · doi:10.1039/c2an35645g · Cited by 46
Li, Z., Huo, P., Gong, C., Deng, C., & Pu, S. (2020) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-020-02935-8 · Cited by 37
Selleri, P., Girolamo, N. D., & Novari, G. (2014) · Journal of the American Veterinary Medical Association · doi:10.2460/javma.245.1.87 · Cited by 40
Clinical Utility of SMBG: Recommendations on the Use and Reporting of SMBG in Clinical Research
Schnell, O., Barnard, K., Bergenstal, R., Bosi, E., Garg, S., Guerci, B., Haak, T., Hirsch, I. B., Ji, L., Joshi, S. R., et al. (2015) · Diabetes Care · doi:10.2337/dc14-2919 · Cited by 36
Noninvasive photoacoustic measurement of glucose by data fusion
Zhang, R., Gao, F., Feng, X., Liu, S., Kishor, R., Luo, Y., & Zheng, Y. (2017) · The Analyst · doi:10.1039/c7an00743d · Cited by 37
Klonoff, D. C. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400301 · Cited by 37
Piao, H., Choi, Y.-H., Kim, J., Park, D., Jia, L., Khang, D., & Choi, H. (2023) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2023.115932 · Cited by 36
Diabetic Alert Dogs: A Preliminary Survey of Current Users
Gonder-Frederick, L. A., Rice, P., Warren, D., Vajda, K., & Shepard, J. A. (2013) · Diabetes Care · doi:10.2337/dc12-1998 · Cited by 40
Intensive Insulin Therapy in Critically Ill Hospitalized Patients: Making it Safe and Effective
Klonoff, D. C. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500330 · Cited by 39
Distributed electrochemical sensors: recent advances and barriers to market adoption
Hoekstra, R., Blondeau, P., & Andrade, F. J. (2018) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-018-1104-9 · Cited by 38
Lane, S. L., Koenig, A., & Brainard, B. M. (2015) · Journal of the American Veterinary Medical Association · doi:10.2460/javma.246.3.307 · Cited by 38
Lindholm, C., & Altimiras, J. (2016) · Comparative Biochemistry and Physiology Part A Molecular & Integrative Physiology · doi:10.1016/j.cbpa.2016.04.009 · Cited by 39
Glycemic Targets in Pregnancies Affected by Diabetes: Historical Perspective and Future Directions
Hernandez, T. L. (2014) · Current Diabetes Reports · doi:10.1007/s11892-014-0565-2 · Cited by 39
Alebiosu, C. O., Familoni, O. B., Ogunsemi, O. O., Raimi, T., Balogun, W., Odusan, O., Oguntona, S., Olunuga, T. O., Kolawole, B., Ikem, R. T., et al. (2013) · Indian Journal of Endocrinology and Metabolism · doi:10.4103/2230-8210.113756 · Cited by 34
Koenig, A., & Verlander, L. L. (2015) · Journal of the American Veterinary Medical Association · doi:10.2460/javma.247.9.1027 · Cited by 33
Bajgrowicz-Cieslak, M., Alqurashi, Y., Elshereif, M. I., Yetisen, A. K., Hassan, M. U., & Butt, H. (2017) · RSC Advances · doi:10.1039/c7ra11184c · Cited by 32
Osuna, V., Aparicio-Martínez, E. P., Dominguez, R. B., & Vega‐Ríos, A. (2024) · Chemosensors · doi:10.3390/chemosensors12080159 · Cited by 32
Ghosh, M., & Bora, V. R. (2025) · Discover Medicine · doi:10.1007/s44337-025-00273-1 · Cited by 39
Mussel-Inspired Electro-Cross-Linking of Enzymes for the Development of Biosensors
El‐Maiss, J., Cuccarese, M., Maerten, C., Lupattelli, P., Chiummiento, L., Funicello, M., Schaaf, P., Jierry, L., & Boulmedais, F. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b04764 · Cited by 34
O’Malley, E. G., Reynolds, C. M. E., O’Kelly, R., Killalea, A. G., Sheehan, S. R., & Turner, M. J. (2020) · Clinical Chemistry · doi:10.1093/clinchem/hvz005 · Cited by 33
Frequency and Predictors of Self-Reported Hypoglycemia in Insulin-Treated Diabetes
Malkani, S., & Kotwal, A. (2017) · Journal of Diabetes Research · doi:10.1155/2017/7425925 · Cited by 32
El estado actual y las nuevas perspectivas en sensores de glucosa no invasivos
Losoya-Leal, A., Camacho-León, S., Dieck-Assad, G., & Martinez-Chapa, S. O. (2012) · Revista Mexicana de Ingeniería Biomédica · Cited by 31
Metadata
- Authors
- Tonyushkina, K., & Nichols, J. H.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2009-07
- Volume
- 3
- Issue
- 4
- Pages
- 971-980
- ISSN
- 1932-2968 (ISSN-L)
- OpenAlex
- W2112149778
- Cited by
- 406
- References
- 44
- FWCI
- 6.30
- Type
- journal article
- Language
- en
- Open access
- green
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.